Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 40 added, 0 removed)
- image-20220824152217-1.png
- image-20220824152928-1.png
- image-20220824161345-1.png
- image-20220824161450-2.png
- image-20220824162339-1.png
- image-20220824162342-2.png
- image-20220824162459-3.png
- image-20220824163110-1.png
- image-20220824163305-2.png
- image-20220824163448-3.png
- image-20220824164346-1.png
- image-20220825100807-1.png
- image-20220825100814-3.png
- image-20220825100845-4.png
- image-20220825102641-1.png
- image-20220825102649-2.png
- image-20220825102844-3.png
- image-20220825103350-4.png
- image-20220825103421-5.png
- image-20220825104904-1.png
- image-20220825105105-2.png
- image-20220825105533-3.png
- image-20220825112403-1.png
- image-20220825142437-1.png
- image-20220825142659-1.png
- image-20220825143728-1.png
- image-20220825160227-1.png
- image-20220825160341-2.png
- image-20220825160648-3.png
- image-20220825160820-4.png
- image-20220825160925-5.png
- image-20220825160929-6.png
- image-20220825161440-7.png
- image-20220825161612-8.png
- image-20220831155101-1.png
- image-20220831155129-2.png
- image-20220831155157-3.png
- image-20220831160010-4.png
- image-20220831160055-5.png
- image-20220831161041-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,10 @@ 1 -= (% style="color:inherit; font-family:inherit"%)**WECON PLC**(%%)=1 += Create communication with WECON PLC = 2 2 3 -== **LX3V 3 +== **LX3V Serial Protocol** == 4 4 5 -Supported series: W ECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -** HMISettings**7 +**1)V-BOX setting** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,8 +15,9 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**Address List** 18 +**2)Address List** 19 19 20 + 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 22 22 |Y|Y|Y o|0~~303237| ... ... @@ -33,8 +33,12 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**C ableWiring**37 +**3)Configure the communication protocol** 37 37 39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] 40 + 41 +**4)Cable Wiring** 42 + 38 38 * **RS422** 39 39 40 40 [[image:image-20220824120614-5.png]] ... ... @@ -45,7 +45,7 @@ 45 45 46 46 == **LX5V Serial Protocol** == 47 47 48 -This example introduces the establishment of serial port communication between WeconV-BOX and LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.53 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 49 49 50 50 **Software configuration of PLC** 51 51 ... ... @@ -89,7 +89,6 @@ 89 89 90 90 [[image:image-20220824104909-2.png]] 91 91 92 - 93 93 **3)Set communication port parameters** 94 94 95 95 Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. ... ... @@ -172,16 +172,16 @@ 172 172 173 173 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 174 174 175 -= **Rockwell PLC** = 179 += Create communication with **Rockwell PLC** = 176 176 177 177 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 178 178 179 179 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 180 180 181 -** HMISettings**185 +**1)PLC Settings** 182 182 183 183 |**Item**|**Settings**|**Note** 184 -|Protocol|Allen-Bradlley MicroLogix|188 +|Protocol|Allen-Bradlley DF1 Advanced| 185 185 |Connection|RS232| 186 186 |Baud rate|19200| 187 187 |Data bit|8| ... ... @@ -189,7 +189,7 @@ 189 189 |Stop bit|1| 190 190 |PLC station No.|1| 191 191 192 -**Address List** 196 +**2)Address List** 193 193 194 194 |**Type**|**Device registers**|**Format**|**Range**|**Note** 195 195 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -207,14 +207,14 @@ 207 207 |T|T nnhh|0~~ffff 208 208 |R|R nnhh|0~~ffff 209 209 210 -**C ableWiring**214 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 211 211 216 +**4)Configure the communication protocol** 217 + 212 212 [[image:image-20220824110724-1.png]] 213 213 220 +== **Micro850_FreeTag Protocol** == 214 214 215 - 216 -== **CompactLogix Protocol** == 217 - 218 218 ((( 219 219 ((( 220 220 This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -352,7 +352,7 @@ 352 352 353 353 ((( 354 354 ((( 355 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 356 356 ))) 357 357 358 358 ... ... @@ -375,7 +375,7 @@ 375 375 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 376 376 ))) 377 377 378 -[[image:image-20220 714162814-10.png]]382 +[[image:image-20220824164346-1.png]] 379 379 380 380 381 381 ((( ... ... @@ -421,69 +421,800 @@ 421 421 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 422 422 423 423 424 -= **Siemens PLC** = 428 += Create communication with **Siemens PLC** = 425 425 426 426 == **S7-200 Smart Ethernet Protocol** == 427 427 428 428 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 433 + 434 + 435 +== **S7-300 Ethernet Protocol** == 436 + 437 +Supported Series: Siemens S7-300 series PLC 438 + 439 +**1)PLC Setting** 440 + 441 +|**Items**|**Settings**|**Note** 442 +|Protocol|Simens S7-300 Ethernet| 443 +|Connection|Ethernet| 444 +|Port No.|102| 445 +|PLC station No.|2|Need to be same as the PLC setting 446 + 447 +**2)Address List** 448 + 449 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 450 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 451 +|Q|Q|Q ddddd.o|0.0~~99999.7| 452 +|M|M|M ddddd.o|0.0~~99999.7| 453 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 454 +nn: block number; 455 + 456 +dddd: address; 429 429 ))) 458 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 459 +|Q|QW|QW ddddd|0~~99999| 460 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 461 +|MW|MW ddddd|0~~99999|((( 462 +MW0=MB(0~~1) 463 + 464 +MW2=MB(2~~3) 465 + 466 +Address value is a multiple of 2 430 430 ))) 468 +|MD|MD ddddd|0~~99999|((( 469 +MD0=MB(0~~3) 431 431 471 +MD4=MB(4~~7) 472 + 473 +Address value is a multiple of 4 474 +))) 475 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 476 +nn: block number; 477 + 478 +dddd: address 479 +))) 480 +|DBxDBW|DBxDBW nndddd|0~~99999999 481 +|DBxDBD|DBxDBD nndddd|0~~99999999 482 + 483 +**3)Configure the communication protocol** 484 + 485 +[[image:image-20220824161345-1.png]] 486 + 487 +**4)Cable Wiring** 488 + 489 +[[image:image-20220824161450-2.png]] 490 +))) 491 +))) 492 + 432 432 == **S7-1200 Ethernet Protocol** == 433 433 434 434 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 435 435 436 -= ** MitsubishiPLC** =497 +== **S7-XXX Ethernet Protocol** == 437 437 438 - == **MitsubishiFXSeriesProtocol**==499 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 439 439 440 - [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]501 +**1)PLC Setting** 441 441 442 -= **Delta PLC** = 503 +|=**Items**|=**Settings**|=**Note** 504 +|Protocol|Siemens S7-XXX| 505 +|Connection|Ethernet| 506 +|Port No.|102| 507 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 508 +|HMI No.|Rack (Default as 0)| 443 443 510 +Slot from TIA Portal is equal to Device No. of V-net 511 + 512 +Rack from TIA Portal is equal to HMI No. of V-net 513 + 514 +[[image:image-20220824162459-3.png]] 515 + 516 +[[image:image-20220824163305-2.png]] 517 + 518 +**2)Address List** 519 + 520 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 521 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 522 +d:0~-~-9999 523 + 524 +o:0-7 525 +)))| 526 +|Q|Q|Q d.o|((( 527 +d:0~-~-9999 528 + 529 +o:0-7 530 +)))| 531 +|M|M|M d.o|((( 532 +d:0~-~-9999 533 + 534 +o:0-7 535 +)))| 536 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 537 +nn:0-9999, 538 + 539 +dddd:0-9999, 540 + 541 +o:0-7 542 +)))|((( 543 +nn:DB No. 544 + 545 +dddd:address value 546 + 547 +o: digit address 548 +))) 549 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 550 +|M|MW|MW d|d:0-99999|((( 551 +MW0=MB(0~~1) 552 + 553 +MW2=MB(2~~3) 554 + 555 +Address value is a multiple of 2 556 +))) 557 +|M|MD|MD d|d:0-99999|((( 558 +MD0=MB(0~~3) 559 + 560 +MD4=MB(4~~7) 561 + 562 +Address value is a multiple of 4 563 +))) 564 +|I|IW|IW d|d:0-99999| 565 +|Q|QW|QW d|d:0-99999| 566 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 567 +nn:0-9999 568 + 569 +dddd:0-9999 570 +)))|((( 571 +nn:DB No. 572 + 573 +dddd:address value 574 +))) 575 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 576 +nn:0-9999 577 + 578 +dddd:0-9999 579 +)))|((( 580 +nn:DB No. 581 + 582 +dddd:address value 583 + 584 +Address value is a multiple of 2 585 +))) 586 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 587 +nn:0-9999 588 + 589 +dddd:0-9999 590 +)))|((( 591 +nn:DB No. 592 + 593 +dddd:address value 594 + 595 +Address value is a multiple of 4 596 +))) 597 + 598 +**3)Configure the communication protocol** 599 + 600 +[[image:image-20220824163448-3.png]] 601 + 602 +**✎Note:** 603 + 604 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 605 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 606 + 607 +**4)Cable Wiring** 608 + 609 +[[image:image-20220824162342-2.png]] 610 + 611 += Create communication with **Mitsubishi PLC** = 612 + 613 +== **FX1S,1N,2N Serial Protocol** == 614 + 615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 616 + 617 +**1)V-BOX Settings** 618 + 619 +|**Item**|**Settings**|**Note** 620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 621 +|Connection|RS422/RS485/RS232| 622 +|Baud rate|9600~~115200| 623 +|Data bit|7/8| 624 +|Parity|EVEN/Odd/None| 625 +|Stop bit|1/2| 626 +|PLC station No.|1~~255| 627 + 628 +**2)Address List** 629 + 630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 632 +|Y|Y|Y o|0~~303237| 633 +|M|M|M d|0~~99999| 634 +|T|T|T d|0~~99999| 635 +|C|C|C d|0~~99999| 636 +|S|S|S d|0~~99999| 637 +|SM|SM|SM d|8000~~9999| 638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|T|T|T d|0~~99999| 642 +|C|C|C d|0~~199| 643 +|D|D|D d|0~~7999| 644 +|S|S|S d|0~~99999| 645 +|SD|SD|SD d|8000~~9999| 646 + 647 +**3)Configure the communication protocol** 648 + 649 +[[image:image-20220825102844-3.png]] 650 + 651 +**4)Cable Wiring** 652 + 653 +* **RS422** 654 + 655 +[[image:image-20220825103350-4.png]] 656 + 657 +[[image:image-20220825100845-4.png]] 658 + 659 + 660 +== **FX3U,3G,3GA Serial Protocol** == 661 + 662 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 663 + 664 +**1)V-BOX Settings** 665 + 666 +|**Item**|**Settings**|**Note** 667 +|Protocol|Mitsubishi FX3U/3G/3GA| 668 +|Connection|RS422/RS485/RS232| 669 +|Baud rate|9600~~115200| 670 +|Data bit|7/8| 671 +|Parity|EVEN/Odd/None| 672 +|Stop bit|1/2| 673 +|PLC station No.|1~~255| 674 + 675 +**2)Address List** 676 + 677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 678 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 679 +|Y|Y|Y o|0~~303237| 680 +|M|M|M d|0~~99999| 681 +|T|T|T d|0~~99999| 682 +|C|C|C d|0~~99999| 683 +|S|S|S d|0~~99999| 684 +|SM|SM|SM d|8000~~9999| 685 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 686 +|Y|Y|Y o|0~~303237| 687 +|M|M|M d|0~~99999| 688 +|T|T|T d|0~~99999| 689 +|C|C|C d|0~~199| 690 +|D|D|D d|0~~7999| 691 +|S|S|S d|0~~99999| 692 +|SD|SD|SD d|8000~~9999| 693 + 694 +**3)Configure the communication protocol** 695 + 696 +[[image:image-20220825102649-2.png]] 697 + 698 +**4)Cable Wiring** 699 + 700 +* **RS422** 701 + 702 +[[image:image-20220825103421-5.png]] 703 + 704 +[[image:image-20220825100845-4.png]] 705 + 706 + 707 +== **FX5U Serial Protocol** == 708 + 709 +Mitsubishi FX5U series PLC 710 + 711 +**1)V-BOX Settings** 712 + 713 +|**Item**|**Settings**|**Note** 714 +|Protocol|Mitsubishi FX5U| 715 +|Connection|RS422/RS485| 716 +|Baud rate|9600| 717 +|Data bit|7| 718 +|Parity|Odd| 719 +|Stop bit|1| 720 +|PLC station No.|1~~255|Need to be the same as PLC settings 721 + 722 +**2)Address List** 723 + 724 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 725 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 726 +|Y|Y|Y o|0~~303237| 727 +|M|M|M d|0~~99999| 728 +|B|B|B h|0~~7FFF| 729 +|F|F|F d|0~~32767| 730 +|SB|SB|SB h|0~~7FFF| 731 +|TS|TS|TS d|0~~1023| 732 +|TC|TC|TC d|0~~1023| 733 +|STS|STS|STS d|0~~1023| 734 +|STC|STC|STS d|0~~1023| 735 +|CS|CS|CS d|0~~1023| 736 +|CC|CC|CC d|0~~1023| 737 +|SM|SM|SM d|0~~9999| 738 +|L|L|L d|0~~32767| 739 +|S|S|S d|0~~4095| 740 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 741 +|TN|TN|TN d|0~~1023| 742 +|STN|STN|STN d|0~~1023| 743 +|CN|CN|CN d|0~~1023| 744 +|R|R|R d|0~~32767| 745 +|SW|SW|SW h|0~~7FFF| 746 +|Z|Z|Z d|0~~23| 747 +|D|D|D d|0~~7999| 748 +|SD|SD|SD d|0~~11999| 749 + 750 +**3)PLC Settings (GX Works 3)** 751 + 752 +Create a blank FX5U project 753 + 754 +Find the 485 serial port module in the system navigation bar and double click to enter the settings. 755 + 756 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 757 + 758 +Select protocol in the setting item, and set parameters. 759 + 760 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 761 + 762 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 763 + 764 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 765 + 766 +Click the [Apply] button to finish the setting. 767 + 768 +Click download and select the items as below, then click [execute] to download the configuration to PLC. 769 + 770 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 771 + 772 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 773 + 774 +Done. 775 + 776 +**4)Configure the communication protocol** 777 + 778 +[[image:image-20220825104904-1.png]] 779 + 780 +**5)Cable Wiring** 781 + 782 + 783 +* **RS422** 784 + 785 +[[image:image-20220825105105-2.png]] 786 + 787 +[[image:image-20220825105533-3.png]] 788 + 789 +== **FX5U Ethernet Protocol** == 790 + 791 +Mitsubishi FX5U series PLC 792 + 793 +**1)V-BOX Settings** 794 + 795 +|**Items**|**Settings**|**Note** 796 +|Protocol|Mitsubishi FX5U| 797 +|Connection|Ethernet| 798 +|Port No.|5002|Must be the same as the PLC setting 799 +|PLC station No.|0| 800 + 801 +**2)Address List** 802 + 803 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 804 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 805 +|Y|Y|Y o|0~~303237| 806 +|M|M|M d|0~~99999| 807 +|B|B|B h|0~~7FFF| 808 +|F|F|F d|0~~32767| 809 +|SB|SB|SB h|0~~7FFF| 810 +|TS|TS|TS d|0~~1023| 811 +|TC|TC|TC d|0~~1023| 812 +|STS|STS|STS d|0~~1023| 813 +|STC|STC|STS d|0~~1023| 814 +|CS|CS|CS d|0~~1023| 815 +|CC|CC|CC d|0~~1023| 816 +|SM|SM|SM d|0~~9999| 817 +|L|L|L d|0~~32767| 818 +|S|S|S d|0~~4095| 819 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 820 +|TN|TN|TN d|0~~1023| 821 +|STN|STN|STN d|0~~1023| 822 +|CN|CN|CN d|0~~1023| 823 +|R|R|R d|0~~32767| 824 +|SW|SW|SW h|0~~7FFF| 825 +|Z|Z|Z d|0~~23| 826 +|D|D|D d|0~~7999| 827 +|SD|SD|SD d|0~~11999| 828 + 829 +**3)PLC Settings (GX Works 3)** 830 + 831 +Find the [Ethernet port] in the navigation area. 832 + 833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 834 + 835 +Select [Own Node Settings] in the [Setting Item List]; 836 + 837 +Set [IP Address], [Subnet Mask], [Default Gateway]; 838 + 839 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 840 + 841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 842 + 843 +Select [SLMP Connection Module] and add into host station as below picture shows; 844 + 845 +Set Port number as 5002 (this is necessary settings); 846 + 847 +Click [Close with Reflecting the Setting] to save and close window; 848 + 849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 850 + 851 +Click [Apply] to completed Etherenet settings; 852 + 853 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 854 + 855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 856 + 857 +**4)Configure the communication protocol** 858 + 859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 + 861 +**5)电缆布线** 862 + 863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 + 865 + 866 +== **L02 Serial Protocol** == 867 + 868 +Mitsubishi L02 series CPU built-in serial port. 869 + 870 +**1)V-BOX Settings** 871 + 872 +|**Item**|**Settings**|**Note** 873 +|Protocol|Mitsubishi L02| 874 +|Connection|RS422| 875 +|Baud rate|115200| 876 +|Data bit|8| 877 +|Parity|Odd| 878 +|Stop bit|1| 879 +|PLC station No.|1~~255|Need to be the same as PLC settings 880 + 881 +**2)Address List** 882 + 883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 884 +|Bit|X|X|X h|0~~FFFF| 885 +|Bit|Y|Y|Y h|0~~FFFF| 886 +|Bit|M|M|M d|0~~9999| 887 +|Bit|L|L|L d|0~~9999| 888 +|Bit|F|F|F d|0~~9999| 889 +|Bit|B|B|B h|0~~FFFF| 890 +|Bit|V|V|V d|0~~2047| 891 +|Bit|TC|TC|TC d|0~~9999| 892 +|Bit|SS|SS|SS d|0~~9999| 893 +|Bit|SC|SC|SC d|0~~9999| 894 +|Bit|CS|CS|CS d|0~~9999| 895 +|Bit|CC|CC|CC d|0~~9999| 896 +|Bit|SB|SB|SB h|0~~FFFF| 897 +|Bit|SM|SM|SM d|0~~2047| 898 +|Bit|STS|STS|STS d|0~~1023| 899 +|Bit|S|S|S d|0~~9999| 900 +|Bit|DX|DX|DX h|0~~FFFF| 901 +|Bit|DY|DY|DY h|0~~FFFF| 902 +|Bit|TS|TS|TS d|0~~9999| 903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 904 +|Word|W|W|W h|0~~FFFF| 905 +|Word|TN|TN|TN d|0~~99999| 906 +|Word|SN|SN|SN d|0~~99999| 907 +|Word|CN|CN|CN d|0~~99999| 908 +|Word|R|R|R d|0~~99999| 909 +|Word|SW|SW|SW h|0~~FFFF| 910 +|Word|Z|Z|Z d|0~~99999| 911 +|Word|ZR|ZR|ZR h|0~~FFFF| 912 +|Word|D|D|D d|0~~99999| 913 + 914 +**3)Communication Settings** 915 + 916 +[[image:image-20220825160648-3.png]] 917 + 918 +**4)Cable Wiring** 919 + 920 +* **RS422** 921 + 922 +[[image:image-20220825161612-8.png]] 923 + 924 +[[image:image-20220825160820-4.png]] 925 + 926 +== **L02 Ethernet Protocol** == 927 + 928 +Mitsubishi L series CPU built-in Ethernet port. 929 + 930 +**1)V-BOX Settings** 931 + 932 +|**Items**|**Settings**|**Note** 933 +|Protocol|MIT L02 CPU MELSEC| 934 +|Connection|Ethernet| 935 +|Port No.|1025|Must be the same as the PLC setting 936 +|PLC station No.|0|Must be the same as the PLC setting 937 + 938 +**2)Address List** 939 + 940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 941 +|Bit|X|X|X h|0~~FFFF| 942 +|Bit|Y|Y|Y h|0~~FFFF| 943 +|Bit|M|M|M d|0~~9999| 944 +|Bit|L|L|L d|0~~9999| 945 +|Bit|F|F|F d|0~~9999| 946 +|Bit|B|B|B h|0~~FFFF| 947 +|Bit|V|V|V d|0~~2047| 948 +|Bit|TC|TC|TC d|0~~9999| 949 +|Bit|SS|SS|SS d|0~~9999| 950 +|Bit|SC|SC|SC d|0~~9999| 951 +|Bit|CS|CS|CS d|0~~9999| 952 +|Bit|CC|CC|CC d|0~~9999| 953 +|Bit|SB|SB|SB h|0~~FFFF| 954 +|Bit|SM|SM|SM d|0~~2047| 955 +|Bit|STS|STS|STS d|0~~1023| 956 +|Bit|S|S|S d|0~~9999| 957 +|Bit|DX|DX|DX h|0~~FFFF| 958 +|Bit|DY|DY|DY h|0~~FFFF| 959 +|Bit|TS|TS|TS d|0~~9999| 960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 961 +|Word|W|W|W h|0~~FFFF| 962 +|Word|TN|TN|TN d|0~~99999| 963 +|Word|SN|SN|SN d|0~~99999| 964 +|Word|CN|CN|CN d|0~~99999| 965 +|Word|R|R|R d|0~~99999| 966 +|Word|SW|SW|SW h|0~~FFFF| 967 +|Word|Z|Z|Z d|0~~99999| 968 +|Word|ZR|ZR|ZR h|0~~FFFF| 969 +|Word|D|D|D d|0~~99999| 970 + 971 +**3)PLC Settings (GX Works2 )** 972 + 973 +Create a project 974 + 975 +Set PLC IP, subnet mask and gateway; 976 + 977 +Select [Binary Code] as communication data code; 978 + 979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 980 + 981 +Set PLC port number, for example 1025 982 + 983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 984 + 985 +Save settings; 986 + 987 +Download project into PLC device; 988 + 989 +Restart PLC device; 990 + 991 +**4)Configure the communication protocol** 992 + 993 +[[image:image-20220825142659-1.png]] 994 + 995 +**5)Cable Wiring** 996 + 997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 998 + 999 +== **QJ71E71 Ethernet Protocol** == 1000 + 1001 +Mitsubishi QJ71E71 Ethernet communication module; 1002 + 1003 +**1)V-BOX Settings** 1004 + 1005 +|**Items**|**Settings**|**Note** 1006 +|Protocol|MIT QJ71E71 MELSEC| 1007 +|Connection|Ethernet| 1008 +|Port No.|1025|Must be the same as the PLC setting 1009 +|PLC station No.|0|Must be the same as the PLC setting 1010 + 1011 +**2)Address List** 1012 + 1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 1015 +|Y|Y|Y h|0~~1FFF| 1016 +|M|M|M d|0~~99999| 1017 +|L|L|L d|0~~8191| 1018 +|F|F|F d|0~~2047| 1019 +|B|B|B h|0~~1FFF| 1020 +|V|V|V d|0~~2047| 1021 +|TS|TS|TS d|0~~2047| 1022 +|TC|TC|TC d|0~~2047| 1023 +|SS|SS|SS d|0~~2047| 1024 +|SC|SC|SC d|0~~2047| 1025 +|CS|CS|CS d|0~~1023| 1026 +|CC|CC|CC d|0~~1023| 1027 +|SB|SB|SB h|0~~7FF| 1028 +|S|S|S d|0~~8191| 1029 +|DX|DX|DX h|0~~1FFF| 1030 +|DY|DY|DY h|0~~1FFF| 1031 +|SM|SM|SM d|8000~~9999| 1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 1033 +|D|D|D d|0~~12287| 1034 +|W|W|W h|0~~1FFF| 1035 +|TN|TN|TN d|0~~2047| 1036 +|SN|SN|SN d|0~~2047| 1037 +|CN|CN|CN d|0~~1023| 1038 +|R|R|R d|0~~32767| 1039 +|SW|SW|SW h|0~~7FF| 1040 +|Z|Z|Z d|0~~15| 1041 +|ZR|ZR|ZR h|0~~FE7FF| 1042 + 1043 +**3)PLC Settings(GX Works2)** 1044 + 1045 +* Click [Ethernet/CC IE/MELSECNET]; 1046 +* Please select [Ethernet] as network type; 1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 1048 +* Select [Online] as Mode; 1049 +* Click [Operation setting] to set IP; 1050 +* Select [Binary Code] as [Communication Data Code]; 1051 +* Set protocol: TCP; 1052 +* Set [unpassive] in [Open system]; 1053 +* Set [receive] in [Fixed buffer]; 1054 +* Set [procedure Exist] in [Fixed buffer communication]; 1055 +* Disable [Pairing open]; 1056 +* Set [No confirm] in [Existence confirmation]; 1057 +* Host station port number: 1025; 1058 +* Save settings; 1059 +* Download project into PLC and restart it 1060 + 1061 +**4)Configure the communication protocol** 1062 + 1063 +[[image:image-20220825143728-1.png]] 1064 + 1065 +**5)Cable Wiring** 1066 + 1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1068 + 1069 += Create communication with **Delta PLC** = 1070 + 444 444 == **DVP Ethernet Protocol** == 445 445 446 -[[ download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 447 447 448 -== **DVP SerialProtocol** ==1075 +== **DVP serial protocol** == 449 449 450 -[[ download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 451 451 452 -= ** Omron PLC** =1079 +== **AS Ethernet Protocol** == 453 453 454 - ==**CP1 SeriesProtocol**==1081 +**1)V-BOX Settings** 455 455 456 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1083 +|=**Items**|=**Settings**|=**Note** 1084 +|Protocol|DELTA AS300 MODBUS TCP| 1085 +|Connection|Ethernet| 1086 +|Port No.|502| 1087 +|Device No.|1| 1088 +|HMI No.|0| 457 457 458 - ==**CJ2M SeriesProtocol**==1090 +**2)Address List** 459 459 460 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1093 +|Bit|X|X|X d|0~~63| 1094 +|Bit|Y|Y|Y d|0~~63| 1095 +|Bit|D|D|D d|0~~29999| 1096 +|Bit|M|M|M d|0~~8191| 1097 +|Bit|SM|SM|SM d|0~~4095| 1098 +|Bit|S|S|S h|0~~2047| 1099 +|Bit|T|T|T d|0~~511| 1100 +|Bit|C|C|C d|0~~511| 1101 +|Bit|HC|HC|HC d|0~~255| 1102 +|Word|X|X|X h|0~~63| 1103 +|Word|Y|Y|Y d|0~~63| 1104 +|Word|SR|SR|SR d|0~~2047| 1105 +|Word|D|D|D d|0~~29999| 1106 +|Word|T|T|T d|0~~511| 1107 +|Word|C|C|C h|0~~511| 1108 +|Word|E|E|E d|0~~9| 461 461 462 - =**ModbusRTU**=1110 +**3)Configure the communication protocol** 463 463 464 -== **V-BOX as master** == 465 465 466 - Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,1113 +[[image:image-20220831160010-4.png]] 467 467 468 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,Data Bit,Parity1115 +**4)Cable Wiring** 469 469 1117 +Figure 1118 + 1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] 1120 + 1121 +Pin Definition Diagram 1122 + 1123 +[[image:image-20220831155157-3.png]] 1124 + 1125 += Create communication with **Omron PLC** = 1126 + 1127 +== **CP1 Series Protocol ** == 1128 + 1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1130 + 1131 +== **CP2M Series Protocol** == 1132 + 1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1134 + 1135 + 1136 +== **EC55 Protocol** == 1137 + 1138 +Supported device: EC55 temperature instrument 1139 + 1140 +**1)V-BOX Settings** 1141 + 1142 +|**Items**|**Settings**|**Note** 1143 +|Protocol|Omron EC55| 1144 +|Connection|RS485 (9600, 2, 7, EVEN)| 1145 +|Port No.|None| 1146 +|PLC station No.|0| 1147 + 1148 +**2)Address List** 1149 + 1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function** 1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 1157 +|CP|-|0-6|Read controller intrinsic property 1158 +|CS|-|0-2|Read controller states 1159 +|CA|-|0-17|Action command 1160 + 1161 +**3)Device Settings** 1162 + 1163 +Omron E5CC PLC configuration 1164 + 1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 1166 + 1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 1168 + 1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 1170 + 1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 1172 + 1173 +**✎Note:** The communication settings for HMI should be consistent with this setting. 1174 + 1175 +**4)Configure the communication protocol** 1176 + 1177 +[[image:image-20220831161041-1.png]] 1178 + 1179 +**5)Cable Wiring** 1180 + 1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1182 + 1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1184 + 1185 +**✎Note:** 1186 + 1187 +* COM3 only available in PI8000/PI9000 series. 1188 +* CA address could not support continuous writing function; 1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid 1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. 1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. 1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 + 1197 += Create communication with **Modbus RTU** = 1198 + 1199 +== **V-BOX as Slave** == 1200 + 1201 +Select the protocol "Modbus RTU Slave (All Fuction)", 1202 + 1203 +Then set baud rate, port, stop bits, data bits, parity. 1204 + 470 470 (% style="text-align:center" %) 471 471 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 472 472 473 -== **V-BOX as slave** ==1208 +== **V-BOX as Master** == 474 474 475 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,1210 +Select the protocol "Modbus RTU Master", 476 476 477 - (% class="mark" %)then setBaudRate,Port,StopBit,DataBit,Parity1212 +Then set baud rate, port, stop bits, data bits, parity 478 478 479 479 (% style="text-align:center" %) 480 480 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 481 481 482 -** AddressList**1217 +**address list** 483 483 484 484 (% class="table-bordered" %) 485 -|** Type**|**Register**|**Function code&Description**486 -|(% rowspan="11" %) Word|(% rowspan="3" %)3|04 (readinputregister:read current binary value in one or more input registers)1220 +|**type**|**register**|**Function code and description** 1221 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 487 487 |06 (write single register: write a binary value to a holding register) 488 488 |10 (write values to multiple addresses ) 489 489 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220824152217-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.6 KB - Content
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content
- image-20220825100807-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100814-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100845-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +403.6 KB - Content
- image-20220825102641-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102649-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102844-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.8 KB - Content
- image-20220825103350-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.9 KB - Content
- image-20220825103421-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.0 KB - Content
- image-20220825104904-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.5 KB - Content
- image-20220825105105-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +78.5 KB - Content
- image-20220825105533-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.8 KB - Content
- image-20220825112403-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +128.1 KB - Content
- image-20220825142437-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.5 KB - Content
- image-20220825142659-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.2 KB - Content
- image-20220825143728-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.7 KB - Content
- image-20220825160227-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +148.8 KB - Content
- image-20220825160341-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.7 KB - Content
- image-20220825160648-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.7 KB - Content
- image-20220825160820-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220825160925-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825160929-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825161440-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.7 KB - Content
- image-20220825161612-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.3 KB - Content
- image-20220831155101-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.6 KB - Content
- image-20220831155129-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.9 KB - Content
- image-20220831155157-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.8 KB - Content
- image-20220831160010-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content
- image-20220831160055-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- image-20220831161041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.1 KB - Content