Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -33,11 +33,11 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**3) V-BOX Set communicationProtocol**36 +**3)Configure the communication protocol** 37 37 38 38 [[image:image-20220824152217-1.png]] 39 39 40 -**4) CableWiring**40 +**4)hardware connection** 41 41 42 42 * **RS422** 43 43 ... ... @@ -49,7 +49,7 @@ 49 49 50 50 == **LX5V Serial Protocol** == 51 51 52 -This example introduces the establishment of serial port communication between WeconV-BOX and LX5V. It is introduced through three parts: PLC software configuration,HMIsoftware configuration, and hardware wiring.52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 53 53 54 54 **Software configuration of PLC** 55 55 ... ... @@ -181,10 +181,10 @@ 181 181 182 182 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 183 183 184 -** HMISettings**184 +**1)PLC Settings** 185 185 186 186 |**Item**|**Settings**|**Note** 187 -|Protocol|Allen-Bradlley MicroLogix|187 +|Protocol|Allen-Bradlley DF1 Advanced| 188 188 |Connection|RS232| 189 189 |Baud rate|19200| 190 190 |Data bit|8| ... ... @@ -192,7 +192,7 @@ 192 192 |Stop bit|1| 193 193 |PLC station No.|1| 194 194 195 -**Address List** 195 +**2)Address List** 196 196 197 197 |**Type**|**Device registers**|**Format**|**Range**|**Note** 198 198 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -210,12 +210,12 @@ 210 210 |T|T nnhh|0~~ffff 211 211 |R|R nnhh|0~~ffff 212 212 213 -**C ableWiring**213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 214 214 215 +**4)Configure the communication protocol** 216 + 215 215 [[image:image-20220824110724-1.png]] 216 216 217 - 218 - 219 219 == **CompactLogix Protocol** == 220 220 221 221 ((( ... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]381 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -429,19 +429,269 @@ 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== **S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**1)PLC Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**2)Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 432 432 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 433 433 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 434 434 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**3)Configure the communication protocol** 483 + 484 +[[image:image-20220824161345-1.png]] 485 + 486 +**4)Cable Wiring** 487 + 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 491 + 435 435 == **S7-1200 Ethernet Protocol** == 436 436 437 437 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 438 438 496 +== **S7-XXX Ethernet Protocol** == 497 + 498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 + 500 +**1)PLC Setting** 501 + 502 +|=**Items**|=**Settings**|=**Note** 503 +|Protocol|Siemens S7-XXX| 504 +|Connection|Ethernet| 505 +|Port No.|102| 506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 +|HMI No.|Rack (Default as 0)| 508 + 509 +Slot from TIA Portal is equal to Device No. of V-net 510 + 511 +Rack from TIA Portal is equal to HMI No. of V-net 512 + 513 +[[image:image-20220824162459-3.png]] 514 + 515 +[[image:image-20220824163305-2.png]] 516 + 517 +**2)Address List** 518 + 519 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 520 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 521 +d:0~-~-9999 522 + 523 +o:0-7 524 +)))| 525 +|Q|Q|Q d.o|((( 526 +d:0~-~-9999 527 + 528 +o:0-7 529 +)))| 530 +|M|M|M d.o|((( 531 +d:0~-~-9999 532 + 533 +o:0-7 534 +)))| 535 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 536 +nn:0-9999, 537 + 538 +dddd:0-9999, 539 + 540 +o:0-7 541 +)))|((( 542 +nn:DB No. 543 + 544 +dddd:address value 545 + 546 +o: digit address 547 +))) 548 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 549 +|M|MW|MW d|d:0-99999|((( 550 +MW0=MB(0~~1) 551 + 552 +MW2=MB(2~~3) 553 + 554 +Address value is a multiple of 2 555 +))) 556 +|M|MD|MD d|d:0-99999|((( 557 +MD0=MB(0~~3) 558 + 559 +MD4=MB(4~~7) 560 + 561 +Address value is a multiple of 4 562 +))) 563 +|I|IW|IW d|d:0-99999| 564 +|Q|QW|QW d|d:0-99999| 565 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 566 +nn:0-9999 567 + 568 +dddd:0-9999 569 +)))|((( 570 +nn:DB No. 571 + 572 +dddd:address value 573 +))) 574 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 575 +nn:0-9999 576 + 577 +dddd:0-9999 578 +)))|((( 579 +nn:DB No. 580 + 581 +dddd:address value 582 + 583 +Address value is a multiple of 2 584 +))) 585 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 586 +nn:0-9999 587 + 588 +dddd:0-9999 589 +)))|((( 590 +nn:DB No. 591 + 592 +dddd:address value 593 + 594 +Address value is a multiple of 4 595 +))) 596 + 597 +**3)Configure the communication protocol** 598 + 599 +[[image:image-20220824163448-3.png]] 600 + 601 +**✎Note:** 602 + 603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 + 606 +**4)Cable Wiring** 607 + 608 +[[image:image-20220824162342-2.png]] 609 + 610 + 439 439 = **Mitsubishi PLC** = 440 440 441 -== ** MitsubishiFX Series Protocol** ==613 +== **FX Series Protocol** == 442 442 443 443 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 444 444 617 + 618 +== **FX5U Ethernet Protocol** == 619 + 620 +Mitsubishi FX5U series PLC 621 + 622 +**HMI Settings** 623 + 624 +|**Items**|**Settings**|**Note** 625 +|Protocol|Mitsubishi FX5U| 626 +|Connection|Ethernet| 627 +|Port No.|5002|Must be the same as the PLC setting 628 +|PLC station No.|0| 629 + 630 +**Address List** 631 + 632 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 633 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 634 +|Y|Y|Y o|0~~303237| 635 +|M|M|M d|0~~99999| 636 +|B|B|B h|0~~7FFF| 637 +|F|F|F d|0~~32767| 638 +|SB|SB|SB h|0~~7FFF| 639 +|TS|TS|TS d|0~~1023| 640 +|TC|TC|TC d|0~~1023| 641 +|STS|STS|STS d|0~~1023| 642 +|STC|STC|STS d|0~~1023| 643 +|CS|CS|CS d|0~~1023| 644 +|CC|CC|CC d|0~~1023| 645 +|SM|SM|SM d|0~~9999| 646 +|L|L|L d|0~~32767| 647 +|S|S|S d|0~~4095| 648 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 649 +|TN|TN|TN d|0~~1023| 650 +|STN|STN|STN d|0~~1023| 651 +|CN|CN|CN d|0~~1023| 652 +|R|R|R d|0~~32767| 653 +|SW|SW|SW h|0~~7FFF| 654 +|Z|Z|Z d|0~~23| 655 +|D|D|D d|0~~7999| 656 +|SD|SD|SD d|0~~11999| 657 + 658 +**PLC Settings (GX Works 3)** 659 + 660 +Find the [Ethernet port] in the navigation area. 661 + 662 +(% style="text-align:center" %) 663 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 664 + 665 +Select [Own Node Settings] in the [Setting Item List]; 666 + 667 +Set [IP Address], [Subnet Mask], [Default Gateway]; 668 + 669 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 670 + 671 +(% style="text-align:center" %) 672 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 673 + 674 +Select [SLMP Connection Module] and add into host station as below picture shows; 675 + 676 +Set Port number as 5002 (this is necessary settings); 677 + 678 +Click [Close with Reflecting the Setting] to save and close window; 679 + 680 +(% style="text-align:center" %) 681 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 682 + 683 +Click [Apply] to completed Etherenet settings; 684 + 685 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 686 + 687 +(% style="text-align:center" %) 688 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 689 + 690 +**Cable Wiring** 691 + 692 +(% style="text-align:center" %) 693 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 694 + 445 445 = **Delta PLC** = 446 446 447 447 == **DVP Ethernet Protocol** ==
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content