Summary

Details

Page properties
Content
... ... @@ -33,11 +33,11 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**3)V-BOX Set communication Protocol**
36 +**3)Configure the communication protocol**
37 37  
38 38  [[image:image-20220824152217-1.png]]
39 39  
40 -**4)Cable Wiring**
40 +**4)hardware connection**
41 41  
42 42  * **RS422**
43 43  
... ... @@ -49,7 +49,7 @@
49 49  
50 50  == **LX5V Serial Protocol** ==
51 51  
52 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
53 53  
54 54  **Software configuration of PLC**
55 55  
... ... @@ -181,10 +181,10 @@
181 181  
182 182  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
183 183  
184 -**HMI Settings**
184 +**1)PLC Settings**
185 185  
186 186  |**Item**|**Settings**|**Note**
187 -|Protocol|Allen-Bradlley MicroLogix|
187 +|Protocol|Allen-Bradlley DF1 Advanced|
188 188  |Connection|RS232|
189 189  |Baud rate|19200|
190 190  |Data bit|8|
... ... @@ -192,7 +192,7 @@
192 192  |Stop bit|1|
193 193  |PLC station No.|1|
194 194  
195 -**Address List**
195 +**2)Address List**
196 196  
197 197  |**Type**|**Device registers**|**Format**|**Range**|**Note**
198 198  |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
... ... @@ -210,12 +210,12 @@
210 210  |T|T nnhh|0~~ffff
211 211  |R|R nnhh|0~~ffff
212 212  
213 -**Cable Wiring**
213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
214 214  
215 +**4)Configure the communication protocol**
216 +
215 215  [[image:image-20220824110724-1.png]]
216 216  
217 -
218 -
219 219  == **CompactLogix Protocol** ==
220 220  
221 221  (((
... ... @@ -429,13 +429,195 @@
429 429  == **S7-200 Smart Ethernet Protocol** ==
430 430  
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 +
433 +
434 +== ** S7-300 Ethernet Protocol** ==
435 +
436 +Supported Series: Siemens S7-300 series PLC
437 +
438 +**1)PLC Setting**
439 +
440 +|**Items**|**Settings**|**Note**
441 +|Protocol|Simens S7-300 Ethernet|
442 +|Connection|Ethernet|
443 +|Port No.|102|
444 +|PLC station No.|2|Need to be same as the PLC setting
445 +
446 +**2)Address List**
447 +
448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
450 +|Q|Q|Q ddddd.o|0.0~~99999.7|
451 +|M|M|M ddddd.o|0.0~~99999.7|
452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
453 +nn: block number;
454 +
455 +dddd: address;
432 432  )))
457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
458 +|Q|QW|QW ddddd|0~~99999|
459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
460 +|MW|MW ddddd|0~~99999|(((
461 +MW0=MB(0~~1)
462 +
463 +MW2=MB(2~~3)
464 +
465 +Address value is a multiple of 2
433 433  )))
467 +|MD|MD ddddd|0~~99999|(((
468 +MD0=MB(0~~3)
434 434  
470 +MD4=MB(4~~7)
471 +
472 +Address value is a multiple of 4
473 +)))
474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
475 +nn: block number;
476 +
477 +dddd: address
478 +)))
479 +|DBxDBW|DBxDBW nndddd|0~~99999999
480 +|DBxDBD|DBxDBD nndddd|0~~99999999
481 +
482 +**3)Configure the communication protocol**
483 +
484 +[[image:image-20220824161345-1.png]]
485 +
486 +**Cable Wiring**
487 +
488 +[[image:image-20220824161450-2.png]]
489 +)))
490 +)))
491 +
435 435  == **S7-1200 Ethernet Protocol** ==
436 436  
437 437  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
438 438  
496 +== ** S7-XXX Ethernet** ==
497 +
498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 +
500 +**HMI Setting**
501 +
502 +|=**Items**|=**Settings**|=**Note**
503 +|Protocol|Siemens S7-XXX|
504 +|Connection|Ethernet|
505 +|Port No.|102|
506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 +|HMI No.|Rack (Default as 0)|
508 +
509 +Slot from TIA Portal is equal to Device No. of PIStudio
510 +
511 +Rack from TIA Portal is equal to HMI No. of PIStudio
512 +
513 +(% style="text-align:center" %)
514 +[[image:S7-XXXCommunication Settings.png]]
515 +
516 +(% style="text-align:center" %)
517 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
518 +
519 +**Address List**
520 +
521 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
522 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
523 +d:0~-~-9999
524 +
525 +o:0-7
526 +)))|
527 +|Q|Q|Q d.o|(((
528 +d:0~-~-9999
529 +
530 +o:0-7
531 +)))|
532 +|M|M|M d.o|(((
533 +d:0~-~-9999
534 +
535 +o:0-7
536 +)))|
537 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
538 +nn:0-9999,
539 +
540 +dddd:0-9999,
541 +
542 +o:0-7
543 +)))|(((
544 +nn:DB No.
545 +
546 +dddd:address value
547 +
548 +o: digit address
549 +)))
550 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
551 +|M|MW|MW d|d:0-99999|(((
552 +MW0=MB(0~~1)
553 +
554 +MW2=MB(2~~3)
555 +
556 +Address value is a multiple of 2
557 +)))
558 +|M|MD|MD d|d:0-99999|(((
559 +MD0=MB(0~~3)
560 +
561 +MD4=MB(4~~7)
562 +
563 +Address value is a multiple of 4
564 +)))
565 +|I|IW|IW d|d:0-99999|
566 +|Q|QW|QW d|d:0-99999|
567 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
568 +nn:0-9999
569 +
570 +dddd:0-9999
571 +)))|(((
572 +nn:DB No.
573 +
574 +dddd:address value
575 +)))
576 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
577 +nn:0-9999
578 +
579 +dddd:0-9999
580 +)))|(((
581 +nn:DB No.
582 +
583 +dddd:address value
584 +
585 +Address value is a multiple of 2
586 +)))
587 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
588 +nn:0-9999
589 +
590 +dddd:0-9999
591 +)))|(((
592 +nn:DB No.
593 +
594 +dddd:address value
595 +
596 +Address value is a multiple of 4
597 +)))
598 +
599 +**Communication Settings**
600 +
601 +Enable HMI Ethernet in [Project Settings];
602 +
603 +(% style="text-align:center" %)
604 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
605 +
606 +Set PLC IP in [Device IP] settings;
607 +
608 +(% style="text-align:center" %)
609 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
610 +
611 +**✎Note:**
612 +
613 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
614 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
615 +
616 +**Cable Wiring**
617 +
618 +{{id name="OLE_LINK8"/}}
619 +
620 +
439 439  = **Mitsubishi PLC** =
440 440  
441 441  == **Mitsubishi FX Series Protocol** ==
image-20220824152928-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@