49 49  
50 50  == **LX5V Serial Protocol** ==
51 51  
52 -This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
52 +This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
53 53  
54 54  **Software configuration of PLC**
55 55  
... ... @@ -181,10 +181,10 @@
181 181  
182 182  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
183 183  
184 -**HMI Settings**
184 +**1)PLC Settings**
185 185  
186 186  |**Item**|**Settings**|**Note**
187 -|Protocol|Allen-Bradlley MicroLogix|
187 +|Protocol|Allen-Bradlley DF1 Advanced|
188 188  |Connection|RS232|
189 189  |Baud rate|19200|
190 190  |Data bit|8|
... ... @@ -192,7 +192,7 @@
192 192  |Stop bit|1|
193 193  |PLC station No.|1|
194 194  
195 -**Address List**
195 +**2)Address List**
196 196  
197 197  |**Type**|**Device registers**|**Format**|**Range**|**Note**
198 198  |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
... ... @@ -210,12 +210,12 @@
210 210  |T|T nnhh|0~~ffff
211 211  |R|R nnhh|0~~ffff
212 212  
213 -**Cable Wiring**
213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
214 214  
215 +**4)Configure the communication protocol**
216 +
215 215  [[image:image-20220824110724-1.png]]
216 216  
217 -
218 -
219 219  == **CompactLogix Protocol** ==
220 220  
221 221  (((
... ... @@ -429,13 +429,190 @@
429 429  == **S7-200 Smart Ethernet Protocol** ==
430 430  
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 +
433 +
434 +== ** S7-300 Ethernet Protocol** ==
435 +
436 +Supported Series: Siemens S7-300 series PLC
437 +
438 +**1)PLC Setting**
439 +
440 +|**Items**|**Settings**|**Note**
441 +|Protocol|Simens S7-300 Ethernet|
442 +|Connection|Ethernet|
443 +|Port No.|102|
444 +|PLC station No.|2|Need to be same as the PLC setting
445 +
446 +**2)Address List**
447 +
448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
450 +|Q|Q|Q ddddd.o|0.0~~99999.7|
451 +|M|M|M ddddd.o|0.0~~99999.7|
452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
453 +nn: block number;
454 +
455 +dddd: address;
432 432  )))
457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
458 +|Q|QW|QW ddddd|0~~99999|
459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
460 +|MW|MW ddddd|0~~99999|(((
461 +MW0=MB(0~~1)
462 +
463 +MW2=MB(2~~3)
464 +
465 +Address value is a multiple of 2
433 433  )))
467 +|MD|MD ddddd|0~~99999|(((
468 +MD0=MB(0~~3)
434 434  
470 +MD4=MB(4~~7)
471 +
472 +Address value is a multiple of 4
473 +)))
474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
475 +nn: block number;
476 +
477 +dddd: address
478 +)))
479 +|DBxDBW|DBxDBW nndddd|0~~99999999
480 +|DBxDBD|DBxDBD nndddd|0~~99999999
481 +
482 +**3)Configure the communication protocol**
483 +
484 +[[image:image-20220824161345-1.png]]
485 +
486 +**Cable Wiring**
487 +
488 +[[image:image-20220824161450-2.png]]
489 +)))
490 +)))
491 +
435 435  == **S7-1200 Ethernet Protocol** ==
436 436  
437 437  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
438 438  
496 +== ** S7-XXX Ethernet** ==
497 +
498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 +
500 +**HMI Setting**
501 +
502 +|=**Items**|=**Settings**|=**Note**
503 +|Protocol|Siemens S7-XXX|
504 +|Connection|Ethernet|
505 +|Port No.|102|
506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 +|HMI No.|Rack (Default as 0)|
508 +
509 +Slot from TIA Portal is equal to Device No. of PIStudio
510 +
511 +Rack from TIA Portal is equal to HMI No. of PIStudio
512 +
513 +[[image:image-20220824162459-3.png]]
514 +
515 +**Address List**
516 +
517 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
518 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
519 +d:0~-~-9999
520 +
521 +o:0-7
522 +)))|
523 +|Q|Q|Q d.o|(((
524 +d:0~-~-9999
525 +
526 +o:0-7
527 +)))|
528 +|M|M|M d.o|(((
529 +d:0~-~-9999
530 +
531 +o:0-7
532 +)))|
533 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
534 +nn:0-9999,
535 +
536 +dddd:0-9999,
537 +
538 +o:0-7
539 +)))|(((
540 +nn:DB No.
541 +
542 +dddd:address value
543 +
544 +o: digit address
545 +)))
546 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
547 +|M|MW|MW d|d:0-99999|(((
548 +MW0=MB(0~~1)
549 +
550 +MW2=MB(2~~3)
551 +
552 +Address value is a multiple of 2
553 +)))
554 +|M|MD|MD d|d:0-99999|(((
555 +MD0=MB(0~~3)
556 +
557 +MD4=MB(4~~7)
558 +
559 +Address value is a multiple of 4
560 +)))
561 +|I|IW|IW d|d:0-99999|
562 +|Q|QW|QW d|d:0-99999|
563 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
564 +nn:0-9999
565 +
566 +dddd:0-9999
567 +)))|(((
568 +nn:DB No.
569 +
570 +dddd:address value
571 +)))
572 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
573 +nn:0-9999
574 +
575 +dddd:0-9999
576 +)))|(((
577 +nn:DB No.
578 +
579 +dddd:address value
580 +
581 +Address value is a multiple of 2
582 +)))
583 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
584 +nn:0-9999
585 +
586 +dddd:0-9999
587 +)))|(((
588 +nn:DB No.
589 +
590 +dddd:address value
591 +
592 +Address value is a multiple of 4
593 +)))
594 +
595 +**Communication Settings**
596 +
597 +Enable HMI Ethernet in [Project Settings];
598 +
599 +(% style="text-align:center" %)
600 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
601 +
602 +Set PLC IP in [Device IP] settings;
603 +
604 +(% style="text-align:center" %)
605 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
606 +
607 +**✎Note:**
608 +
609 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
610 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
611 +
612 +**Cable Wiring**
613 +
614 +[[image:image-20220824162342-2.png]]
615 +
439 439  = **Mitsubishi PLC** =
440 440  
441 441  == **Mitsubishi FX Series Protocol** ==
image-20220824152928-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +137.8 KB
Content
image-20220824161345-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824161450-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162339-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162342-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162459-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content