Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,10 +181,10 @@ 181 181 182 182 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 183 183 184 -** HMISettings**184 +**1)PLC Settings** 185 185 186 186 |**Item**|**Settings**|**Note** 187 -|Protocol|Allen-Bradlley MicroLogix|187 +|Protocol|Allen-Bradlley DF1 Advanced| 188 188 |Connection|RS232| 189 189 |Baud rate|19200| 190 190 |Data bit|8| ... ... @@ -192,7 +192,7 @@ 192 192 |Stop bit|1| 193 193 |PLC station No.|1| 194 194 195 -**Address List** 195 +**2)Address List** 196 196 197 197 |**Type**|**Device registers**|**Format**|**Range**|**Note** 198 198 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -210,12 +210,12 @@ 210 210 |T|T nnhh|0~~ffff 211 211 |R|R nnhh|0~~ffff 212 212 213 -**C ableWiring**213 +**3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 214 214 215 +**4)Configure the communication protocol** 216 + 215 215 [[image:image-20220824110724-1.png]] 216 216 217 - 218 - 219 219 == **CompactLogix Protocol** == 220 220 221 221 ((( ... ... @@ -429,13 +429,190 @@ 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== ** S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**1)PLC Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**2)Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 432 432 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 433 433 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 434 434 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**3)Configure the communication protocol** 483 + 484 +[[image:image-20220824161345-1.png]] 485 + 486 +**Cable Wiring** 487 + 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 491 + 435 435 == **S7-1200 Ethernet Protocol** == 436 436 437 437 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 438 438 496 +== **S7-XXX Ethernet Protocol** == 497 + 498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 + 500 +**HMI Setting** 501 + 502 +|=**Items**|=**Settings**|=**Note** 503 +|Protocol|Siemens S7-XXX| 504 +|Connection|Ethernet| 505 +|Port No.|102| 506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 +|HMI No.|Rack (Default as 0)| 508 + 509 +Slot from TIA Portal is equal to Device No. of PIStudio 510 + 511 +Rack from TIA Portal is equal to HMI No. of PIStudio 512 + 513 +[[image:image-20220824162459-3.png]] 514 + 515 +**Address List** 516 + 517 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 518 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 519 +d:0~-~-9999 520 + 521 +o:0-7 522 +)))| 523 +|Q|Q|Q d.o|((( 524 +d:0~-~-9999 525 + 526 +o:0-7 527 +)))| 528 +|M|M|M d.o|((( 529 +d:0~-~-9999 530 + 531 +o:0-7 532 +)))| 533 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 534 +nn:0-9999, 535 + 536 +dddd:0-9999, 537 + 538 +o:0-7 539 +)))|((( 540 +nn:DB No. 541 + 542 +dddd:address value 543 + 544 +o: digit address 545 +))) 546 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 547 +|M|MW|MW d|d:0-99999|((( 548 +MW0=MB(0~~1) 549 + 550 +MW2=MB(2~~3) 551 + 552 +Address value is a multiple of 2 553 +))) 554 +|M|MD|MD d|d:0-99999|((( 555 +MD0=MB(0~~3) 556 + 557 +MD4=MB(4~~7) 558 + 559 +Address value is a multiple of 4 560 +))) 561 +|I|IW|IW d|d:0-99999| 562 +|Q|QW|QW d|d:0-99999| 563 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 564 +nn:0-9999 565 + 566 +dddd:0-9999 567 +)))|((( 568 +nn:DB No. 569 + 570 +dddd:address value 571 +))) 572 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 573 +nn:0-9999 574 + 575 +dddd:0-9999 576 +)))|((( 577 +nn:DB No. 578 + 579 +dddd:address value 580 + 581 +Address value is a multiple of 2 582 +))) 583 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 584 +nn:0-9999 585 + 586 +dddd:0-9999 587 +)))|((( 588 +nn:DB No. 589 + 590 +dddd:address value 591 + 592 +Address value is a multiple of 4 593 +))) 594 + 595 +**Communication Settings** 596 + 597 +Enable HMI Ethernet in [Project Settings]; 598 + 599 +(% style="text-align:center" %) 600 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 601 + 602 +Set PLC IP in [Device IP] settings; 603 + 604 +(% style="text-align:center" %) 605 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 606 + 607 +**✎Note:** 608 + 609 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 610 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 611 + 612 +**Cable Wiring** 613 + 614 +[[image:image-20220824162342-2.png]] 615 + 439 439 = **Mitsubishi PLC** = 440 440 441 441 == **Mitsubishi FX Series Protocol** ==
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.8 KB - Content
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content