... ... @@ -4,7 +4,7 @@
4 4  
5 5  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**1)PLC Settings**
7 +**HMI Settings**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,7 +15,7 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**2)PLC Address List**
18 +**Address List**
19 19  
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
... ... @@ -33,12 +33,8 @@
33 33  |S|S|S d|0~~99999|
34 34  |SD|SD|SD d|8000~~9999|
35 35  
36 -**3)Configure the communication protocol**
36 +**Cable Wiring**
37 37  
38 -[[image:image-20220824152217-1.png]]
39 -
40 -**4)hardware connection**
41 -
42 42  * **RS422**
43 43  
44 44   [[image:image-20220824120614-5.png]]
... ... @@ -49,7 +49,7 @@
49 49  
50 50  == **LX5V Serial Protocol** ==
51 51  
52 -This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
53 53  
54 54  **Software configuration of PLC**
55 55  
... ... @@ -93,6 +93,7 @@
93 93  
94 94  [[image:image-20220824104909-2.png]]
95 95  
92 +
96 96  **3)Set communication port parameters**
97 97  
98 98  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -111,27 +111,31 @@
111 111  
112 112  **1)Hardware wiring diagram**
113 113  
111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 +
114 114  [[image:image-20220824142546-2.png]]
115 115  
116 116  [[image:image-20220824142643-3.png]]
117 117  
118 -The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
119 119  
118 +
119 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
120 +
120 120  == **LX5V-N Ethernet protocol** ==
121 121  
122 -This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
123 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
123 123  
124 124  **Software configuration of PLC**
125 125  
126 126  **1)PLC programming software**
127 127  
128 -[[image:image-20220824142722-1.png]]
129 +[[image:image-20220810164710-1.png]]
129 129  
130 130  **2)New PLC project**
131 131  
132 132  Click New Project and select the PLC model.
133 133  
134 -[[image:image-20220824143613-1.png]]
135 +[[image:image-20220811115454-1.png]]
135 135  
136 136  **3)Set Ethernet port parameters**
137 137  
... ... @@ -143,38 +143,53 @@
143 143  
144 144  subnet mask:255.255.255.0
145 145  
146 -[[image:image-20220824143744-2.png]]
147 +[[image:image-20220811140530-2.png]]
147 147  
148 148  **4)Registers list**
149 149  
150 -[[image:image-20220822172730-4.png]]
151 +[[image:image-20220811102219-3.png]]
151 151  
152 -(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
153 +**HMI software configuration**
153 153  
154 -**1)V-BOX programming software**
155 +**1)HMI programming software**
155 155  
156 - [[image:image-20220824104124-1.png]]
157 + [[image:image-20220810171237-4.png]]
157 157  
158 -**2)V-NET add device**
159 +**2)New HMI project**
159 159  
160 -Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
161 +Click New Project and select the HMI model.
161 161  
162 -[[image:image-20220824104909-2.png]]
163 +[[image:image-20220810172010-5.png]]
163 163  
164 -**3)Set communication Protocol**
165 +**3)Set communication port parameters**
165 165  
166 -Click Communication to configure the LX5V plc protocol and IP address.
167 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
167 167  
168 -[[image:image-20220824144619-1.png]]
169 +HMI IP address:192.168.39.201
169 169  
171 +default gateway:192.168.39.1
172 +
173 +subnet mask:255.255.255.0
174 +
175 +[[image:image-20220811170753-2.png]]
176 +
177 +Next, click Communication Settings to configure the IP of the HMI communication object.
178 +
179 +[[image:image-20220811163047-1.png]]
180 +
170 170  **hardware connection**
171 171  
172 172  **1)Hardware wiring diagram**
173 173  
174 -[[image:image-20220824151127-2.png]]
185 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
175 175  
176 -The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
187 +[[image:image-20220811170248-1.png]]
177 177  
189 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
190 +
191 +(% style="text-align:center" %)
192 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
193 +
178 178  = **Rockwell PLC** =
179 179  
180 180  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
... ... @@ -184,7 +184,7 @@
184 184  **HMI Settings**
185 185  
186 186  |**Item**|**Settings**|**Note**
187 -|Protocol|Allen-Bradlley DF1 Advanced|
203 +|Protocol|Allen-Bradlley MicroLogix|
188 188  |Connection|RS232|
189 189  |Baud rate|19200|
190 190  |Data bit|8|
... ... @@ -210,12 +210,12 @@
210 210  |T|T nnhh|0~~ffff
211 211  |R|R nnhh|0~~ffff
212 212  
213 -**3)Configure the communication protocol**[[image:image-20220824152928-1.png]]
214 -
215 215  **Cable Wiring**
216 216  
217 217  [[image:image-20220824110724-1.png]]
218 218  
233 +
234 +
219 219  == **CompactLogix Protocol** ==
220 220  
221 221  (((
image-20220824143613-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -85.5 KB
Content
image-20220824152217-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -123.6 KB
Content
image-20220824152928-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -137.8 KB
Content