Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,7 +181,7 @@ 181 181 182 182 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 183 183 184 -** HMISettings**184 +**1)PLC Settings** 185 185 186 186 |**Item**|**Settings**|**Note** 187 187 |Protocol|Allen-Bradlley DF1 Advanced| ... ... @@ -192,7 +192,7 @@ 192 192 |Stop bit|1| 193 193 |PLC station No.|1| 194 194 195 -**Address List** 195 +**2)Address List** 196 196 197 197 |**Type**|**Device registers**|**Format**|**Range**|**Note** 198 198 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -212,7 +212,7 @@ 212 212 213 213 **3)Configure the communication protocol**[[image:image-20220824152928-1.png]] 214 214 215 -**C ableWiring**215 +**4)Configure the communication protocol** 216 216 217 217 [[image:image-20220824110724-1.png]] 218 218 ... ... @@ -429,9 +429,84 @@ 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 + 433 + 434 +== ** S7-300 Ethernet Protocol** == 435 + 436 +Supported Series: Siemens S7-300 series PLC 437 + 438 +**HMI Setting** 439 + 440 +|**Items**|**Settings**|**Note** 441 +|Protocol|Simens S7-300 Ethernet| 442 +|Connection|Ethernet| 443 +|Port No.|102| 444 +|PLC station No.|2|Need to be same as the PLC setting 445 + 446 +**Address List** 447 + 448 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 +|Q|Q|Q ddddd.o|0.0~~99999.7| 451 +|M|M|M ddddd.o|0.0~~99999.7| 452 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 +nn: block number; 454 + 455 +dddd: address; 432 432 ))) 457 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 +|Q|QW|QW ddddd|0~~99999| 459 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 +|MW|MW ddddd|0~~99999|((( 461 +MW0=MB(0~~1) 462 + 463 +MW2=MB(2~~3) 464 + 465 +Address value is a multiple of 2 433 433 ))) 467 +|MD|MD ddddd|0~~99999|((( 468 +MD0=MB(0~~3) 434 434 470 +MD4=MB(4~~7) 471 + 472 +Address value is a multiple of 4 473 +))) 474 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 +nn: block number; 476 + 477 +dddd: address 478 +))) 479 +|DBxDBW|DBxDBW nndddd|0~~99999999 480 +|DBxDBD|DBxDBD nndddd|0~~99999999 481 + 482 +**Communication Settings** 483 + 484 +Enable HMI Ethernet in [Project Settings]; 485 + 486 +(% style="text-align:center" %) 487 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 488 + 489 +Set PLC IP in [Device IP] settings; 490 + 491 +(% style="text-align:center" %) 492 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 493 + 494 +* PLC IP Address: PLC IP 495 +* PLC pot No.: 102(fixed) 496 +* Network:TCP_Client_2N(fixed) 497 + 498 +(% style="text-align:center" %) 499 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 500 + 501 +* Wait timeout: depend on actual network situation (more than 1500 ms) 502 + 503 +**Cable Wiring** 504 + 505 +(% style="text-align:center" %) 506 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 507 +))) 508 +))) 509 + 435 435 == **S7-1200 Ethernet Protocol** == 436 436 437 437 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]