Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) PLCSettings**7 +**1)HMI Settings** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,7 +15,7 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**2) PLCAddress List**18 +**2)Address List** 19 19 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| ... ... @@ -33,11 +33,11 @@ 33 33 |S|S|S d|0~~99999| 34 34 |SD|SD|SD d|8000~~9999| 35 35 36 -**3) Configurehecommunicationprotocol**36 +**3)Set communication Protocol** 37 37 38 38 [[image:image-20220824152217-1.png]] 39 39 40 -**4) hardwareconnection**40 +**4)Cable Wiring** 41 41 42 42 * **RS422** 43 43 ... ... @@ -49,7 +49,7 @@ 49 49 50 50 == **LX5V Serial Protocol** == 51 51 52 -This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOXsoftware configuration, and hardware wiring.52 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 53 53 54 54 **Software configuration of PLC** 55 55 ... ... @@ -181,10 +181,10 @@ 181 181 182 182 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 183 183 184 -** 1)PLCSettings**184 +**HMI Settings** 185 185 186 186 |**Item**|**Settings**|**Note** 187 -|Protocol|Allen-Bradlley DF1 Advanced|187 +|Protocol|Allen-Bradlley MicroLogix| 188 188 |Connection|RS232| 189 189 |Baud rate|19200| 190 190 |Data bit|8| ... ... @@ -192,7 +192,7 @@ 192 192 |Stop bit|1| 193 193 |PLC station No.|1| 194 194 195 -** 2)Address List**195 +**Address List** 196 196 197 197 |**Type**|**Device registers**|**Format**|**Range**|**Note** 198 198 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| ... ... @@ -210,12 +210,12 @@ 210 210 |T|T nnhh|0~~ffff 211 211 |R|R nnhh|0~~ffff 212 212 213 -** 3)Configurethe communication protocol**[[image:image-20220824152928-1.png]]213 +**Cable Wiring** 214 214 215 -**4)Configure the communication protocol** 216 - 217 217 [[image:image-20220824110724-1.png]] 218 218 217 + 218 + 219 219 == **CompactLogix Protocol** == 220 220 221 221 ((( ... ... @@ -429,84 +429,9 @@ 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 - 433 - 434 -== ** S7-300 Ethernet** == 435 - 436 -Supported Series: Siemens S7-300 series PLC 437 - 438 -**HMI Setting** 439 - 440 -|**Items**|**Settings**|**Note** 441 -|Protocol|Simens S7-300 Ethernet| 442 -|Connection|Ethernet| 443 -|Port No.|102| 444 -|PLC station No.|2|Need to be same as the PLC setting 445 - 446 -**Address List** 447 - 448 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 450 -|Q|Q|Q ddddd.o|0.0~~99999.7| 451 -|M|M|M ddddd.o|0.0~~99999.7| 452 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 453 -nn: block number; 454 - 455 -dddd: address; 456 456 ))) 457 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 458 -|Q|QW|QW ddddd|0~~99999| 459 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 460 -|MW|MW ddddd|0~~99999|((( 461 -MW0=MB(0~~1) 462 - 463 -MW2=MB(2~~3) 464 - 465 -Address value is a multiple of 2 466 466 ))) 467 -|MD|MD ddddd|0~~99999|((( 468 -MD0=MB(0~~3) 469 469 470 -MD4=MB(4~~7) 471 - 472 -Address value is a multiple of 4 473 -))) 474 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 475 -nn: block number; 476 - 477 -dddd: address 478 -))) 479 -|DBxDBW|DBxDBW nndddd|0~~99999999 480 -|DBxDBD|DBxDBD nndddd|0~~99999999 481 - 482 -**Communication Settings** 483 - 484 -Enable HMI Ethernet in [Project Settings]; 485 - 486 -(% style="text-align:center" %) 487 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 488 - 489 -Set PLC IP in [Device IP] settings; 490 - 491 -(% style="text-align:center" %) 492 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 493 - 494 -* PLC IP Address: PLC IP 495 -* PLC pot No.: 102(fixed) 496 -* Network:TCP_Client_2N(fixed) 497 - 498 -(% style="text-align:center" %) 499 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 500 - 501 -* Wait timeout: depend on actual network situation (more than 1500 ms) 502 - 503 -**Cable Wiring** 504 - 505 -(% style="text-align:center" %) 506 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 507 -))) 508 -))) 509 - 510 510 == **S7-1200 Ethernet Protocol** == 511 511 512 512 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
- image-20220824152928-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -137.8 KB - Content