Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]381 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,11 +431,11 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 434 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 438 -** HMISetting**438 +**1)PLC Setting** 439 439 440 440 |**Items**|**Settings**|**Note** 441 441 |Protocol|Simens S7-300 Ethernet| ... ... @@ -443,7 +443,7 @@ 443 443 |Port No.|102| 444 444 |PLC station No.|2|Need to be same as the PLC setting 445 445 446 -**Address List** 446 +**2)Address List** 447 447 448 448 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 449 |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| ... ... @@ -479,44 +479,218 @@ 479 479 |DBxDBW|DBxDBW nndddd|0~~99999999 480 480 |DBxDBD|DBxDBD nndddd|0~~99999999 481 481 482 -**Communication Settings**482 +**3)Configure the communication protocol** 483 483 484 - EnableHMI Ethernetin [Project Settings];484 +[[image:image-20220824161345-1.png]] 485 485 486 -(% style="text-align:center" %) 487 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 486 +**4)Cable Wiring** 488 488 489 -Set PLC IP in [Device IP] settings; 488 +[[image:image-20220824161450-2.png]] 489 +))) 490 +))) 490 490 491 -(% style="text-align:center" %) 492 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 492 +== **S7-1200 Ethernet Protocol** == 493 493 494 -* PLC IP Address: PLC IP 495 -* PLC pot No.: 102(fixed) 496 -* Network:TCP_Client_2N(fixed) 494 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 497 497 498 -(% style="text-align:center" %) 499 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 496 +== **S7-XXX Ethernet Protocol** == 500 500 501 - * Waittimeout:dependonactualnetwork situation(more than1500ms)498 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 502 502 503 -**C ableWiring**500 +**1)PLC Setting** 504 504 505 -(% style="text-align:center" %) 506 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 502 +|=**Items**|=**Settings**|=**Note** 503 +|Protocol|Siemens S7-XXX| 504 +|Connection|Ethernet| 505 +|Port No.|102| 506 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 +|HMI No.|Rack (Default as 0)| 508 + 509 +Slot from TIA Portal is equal to Device No. of V-net 510 + 511 +Rack from TIA Portal is equal to HMI No. of V-net 512 + 513 +[[image:image-20220824162459-3.png]] 514 + 515 +[[image:image-20220824163305-2.png]] 516 + 517 +**2)Address List** 518 + 519 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 520 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 521 +d:0~-~-9999 522 + 523 +o:0-7 524 +)))| 525 +|Q|Q|Q d.o|((( 526 +d:0~-~-9999 527 + 528 +o:0-7 529 +)))| 530 +|M|M|M d.o|((( 531 +d:0~-~-9999 532 + 533 +o:0-7 534 +)))| 535 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 536 +nn:0-9999, 537 + 538 +dddd:0-9999, 539 + 540 +o:0-7 541 +)))|((( 542 +nn:DB No. 543 + 544 +dddd:address value 545 + 546 +o: digit address 507 507 ))) 548 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 549 +|M|MW|MW d|d:0-99999|((( 550 +MW0=MB(0~~1) 551 + 552 +MW2=MB(2~~3) 553 + 554 +Address value is a multiple of 2 508 508 ))) 556 +|M|MD|MD d|d:0-99999|((( 557 +MD0=MB(0~~3) 509 509 510 -= = **S7-1200 Ethernet Protocol** ==559 +MD4=MB(4~~7) 511 511 512 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 561 +Address value is a multiple of 4 562 +))) 563 +|I|IW|IW d|d:0-99999| 564 +|Q|QW|QW d|d:0-99999| 565 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 566 +nn:0-9999 513 513 568 +dddd:0-9999 569 +)))|((( 570 +nn:DB No. 571 + 572 +dddd:address value 573 +))) 574 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 575 +nn:0-9999 576 + 577 +dddd:0-9999 578 +)))|((( 579 +nn:DB No. 580 + 581 +dddd:address value 582 + 583 +Address value is a multiple of 2 584 +))) 585 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 586 +nn:0-9999 587 + 588 +dddd:0-9999 589 +)))|((( 590 +nn:DB No. 591 + 592 +dddd:address value 593 + 594 +Address value is a multiple of 4 595 +))) 596 + 597 +**3)Configure the communication protocol** 598 + 599 +[[image:image-20220824163448-3.png]] 600 + 601 +**✎Note:** 602 + 603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 + 606 +**4)Cable Wiring** 607 + 608 +[[image:image-20220824162342-2.png]] 609 + 610 + 514 514 = **Mitsubishi PLC** = 515 515 516 -== ** MitsubishiFX Series Protocol** ==613 +== **FX3U Series Protocol** == 517 517 518 518 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 519 519 617 +== **FX5U Ethernet Protocol** == 618 + 619 +Mitsubishi FX5U series PLC 620 + 621 +**HMI Settings** 622 + 623 +|**Items**|**Settings**|**Note** 624 +|Protocol|Mitsubishi FX5U| 625 +|Connection|Ethernet| 626 +|Port No.|5002|Must be the same as the PLC setting 627 +|PLC station No.|0| 628 + 629 +**Address List** 630 + 631 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 632 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 633 +|Y|Y|Y o|0~~303237| 634 +|M|M|M d|0~~99999| 635 +|B|B|B h|0~~7FFF| 636 +|F|F|F d|0~~32767| 637 +|SB|SB|SB h|0~~7FFF| 638 +|TS|TS|TS d|0~~1023| 639 +|TC|TC|TC d|0~~1023| 640 +|STS|STS|STS d|0~~1023| 641 +|STC|STC|STS d|0~~1023| 642 +|CS|CS|CS d|0~~1023| 643 +|CC|CC|CC d|0~~1023| 644 +|SM|SM|SM d|0~~9999| 645 +|L|L|L d|0~~32767| 646 +|S|S|S d|0~~4095| 647 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 648 +|TN|TN|TN d|0~~1023| 649 +|STN|STN|STN d|0~~1023| 650 +|CN|CN|CN d|0~~1023| 651 +|R|R|R d|0~~32767| 652 +|SW|SW|SW h|0~~7FFF| 653 +|Z|Z|Z d|0~~23| 654 +|D|D|D d|0~~7999| 655 +|SD|SD|SD d|0~~11999| 656 + 657 +**PLC Settings (GX Works 3)** 658 + 659 +Find the [Ethernet port] in the navigation area. 660 + 661 +(% style="text-align:center" %) 662 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 663 + 664 +Select [Own Node Settings] in the [Setting Item List]; 665 + 666 +Set [IP Address], [Subnet Mask], [Default Gateway]; 667 + 668 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 669 + 670 +(% style="text-align:center" %) 671 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 672 + 673 +Select [SLMP Connection Module] and add into host station as below picture shows; 674 + 675 +Set Port number as 5002 (this is necessary settings); 676 + 677 +Click [Close with Reflecting the Setting] to save and close window; 678 + 679 +(% style="text-align:center" %) 680 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 681 + 682 +Click [Apply] to completed Etherenet settings; 683 + 684 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 685 + 686 +(% style="text-align:center" %) 687 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 688 + 689 +**Cable Wiring** 690 + 691 +(% style="text-align:center" %) 692 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 693 + 520 520 = **Delta PLC** = 521 521 522 522 == **DVP Ethernet Protocol** ==
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content