Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 9.1
edited by Stone Wu
on 2022/07/12 11:34
Change comment: There is no comment for this version
To version 72.1
edited by Ben
on 2022/08/24 14:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Ben
Content
... ... @@ -1,9 +1,486 @@
1 -= **1 General communication with PLC** =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **1.1 Modbus RTU** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -==== V-Box as master: ====
5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 +**HMI Settings**
8 +
9 +|**Item**|**Settings**|**Note**
10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
11 +|Connection|RS422/RS485|
12 +|Baud rate|9600|
13 +|Data bit|7|
14 +|Parity|EVEN|
15 +|Stop bit|1|
16 +|PLC station No.|1|
17 +
18 +**Address List**
19 +
20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 +|Y|Y|Y o|0~~303237|
23 +|M|M|M d|0~~99999|
24 +|T|T|T d|0~~99999|
25 +|C|C|C d|0~~99999|
26 +|S|S|S d|0~~99999|
27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
28 +|Y|Y|Y o|0~~303237|
29 +|M|M|M d|0~~99999|
30 +|T|T|T d|0~~99999|
31 +|C|C|C d|0~~199|
32 +|D|D|D d|0~~7999|
33 +|S|S|S d|0~~99999|
34 +|SD|SD|SD d|8000~~9999|
35 +
36 +**Cable Wiring**
37 +
38 +* **RS422**
39 +
40 + [[image:image-20220824120614-5.png]]
41 +
42 +* **RS485**
43 +
44 + [[image:image-20220824120524-3.png]]
45 +
46 +== **LX5V Serial Protocol** ==
47 +
48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
49 +
50 +**Software configuration of PLC**
51 +
52 +**1)PLC programming software**
53 +
54 +[[image:image-20220824142722-1.png]]
55 +
56 +**2)New PLC project**
57 +
58 +Click New Project and select the PLC model.
59 +
60 +[[image:image-20220822172623-2.png]]
61 +
62 +**3)Set Serial port parameters**
63 +
64 +Follow the steps below to configure Serial port parameters
65 +
66 +Baud rate:115200
67 +
68 +Data bit:8
69 +
70 +Stop bit:1
71 +
72 +Parity:No verification
73 +
74 +[[image:image-20220822172657-3.png]]
75 +
76 +**4)Registers list**
77 +
78 +[[image:image-20220822172730-4.png]]
79 +
80 +**V-BOX software configuration**
81 +
82 +**1)V-BOX programming software**
83 +
84 + [[image:image-20220824104124-1.png]]
85 +
86 +**2)V-NET add device**
87 +
88 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
89 +
90 +[[image:image-20220824104909-2.png]]
91 +
92 +
93 +**3)Set communication port parameters**
94 +
95 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
96 +
97 +Baud rate:115200
98 +
99 +Data bit:8
100 +
101 +Stop bit:1
102 +
103 +Parity:No verification
104 +
105 +[[image:image-20220824142130-1.png]]
106 +
107 +**hardware connection**
108 +
109 +**1)Hardware wiring diagram**
110 +
111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 +
113 +[[image:image-20220824142546-2.png]]
114 +
115 +[[image:image-20220824142643-3.png]]
116 +
117 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
118 +
119 +
120 +== **LX5V-N Ethernet protocol** ==
121 +
122 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
123 +
124 +**Software configuration of PLC**
125 +
126 +**1)PLC programming software**
127 +
128 +[[image:image-20220824142722-1.png]]
129 +
130 +**2)New PLC project**
131 +
132 +Click New Project and select the PLC model.
133 +
134 +[[image:image-20220822172623-2.png]]
135 +
136 +**3)Set Ethernet port parameters**
137 +
138 +Follow the steps below to configure Ethernet parameters
139 +
140 +PLC IP address:192.168.39.200
141 +
142 +default gateway:192.168.39.1
143 +
144 +subnet mask:255.255.255.0
145 +
146 +[[image:image-20220811140530-2.png]]
147 +
148 +**4)Registers list**
149 +
150 +[[image:image-20220811102219-3.png]]
151 +
152 +**HMI software configuration**
153 +
154 +**1)HMI programming software**
155 +
156 + [[image:image-20220810171237-4.png]]
157 +
158 +**2)New HMI project**
159 +
160 +Click New Project and select the HMI model.
161 +
162 +[[image:image-20220810172010-5.png]]
163 +
164 +**3)Set communication port parameters**
165 +
166 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
167 +
168 +HMI IP address:192.168.39.201
169 +
170 +default gateway:192.168.39.1
171 +
172 +subnet mask:255.255.255.0
173 +
174 +[[image:image-20220811170753-2.png]]
175 +
176 +Next, click Communication Settings to configure the IP of the HMI communication object.
177 +
178 +[[image:image-20220811163047-1.png]]
179 +
180 +**hardware connection**
181 +
182 +**1)Hardware wiring diagram**
183 +
184 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
185 +
186 +[[image:image-20220811170248-1.png]]
187 +
188 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
189 +
190 +(% style="text-align:center" %)
191 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
192 +
193 += **Rockwell PLC** =
194 +
195 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
196 +
197 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
198 +
199 +**HMI Settings**
200 +
201 +|**Item**|**Settings**|**Note**
202 +|Protocol|Allen-Bradlley MicroLogix|
203 +|Connection|RS232|
204 +|Baud rate|19200|
205 +|Data bit|8|
206 +|Parity|None|
207 +|Stop bit|1|
208 +|PLC station No.|1|
209 +
210 +**Address List**
211 +
212 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
213 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
214 +|O|O d.d|0.0~~255.15|
215 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
216 +|S|S d.d|0.0~~255.15|
217 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
218 +|(% rowspan="9" %)Word|S|S d|0~~255|
219 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
220 +|TP|TP nnhh|0~~ffff
221 +|CS|CS nnhh|0~~ffff
222 +|CP|CP nnhh|0~~ffff
223 +|N|N nnhh|0~~ffff
224 +|C|C nnhh|0~~ffff
225 +|T|T nnhh|0~~ffff
226 +|R|R nnhh|0~~ffff
227 +
228 +**Cable Wiring**
229 +
230 +[[image:image-20220824110724-1.png]]
231 +
232 +
233 +
234 +== **CompactLogix Protocol** ==
235 +
236 +(((
237 +(((
238 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
239 +)))
240 +)))
241 +
242 +(((
243 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
244 +(((
245 +**Software configuration of PLC**
246 +)))
247 +
248 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
249 +(((
250 +**1)PLC programming software**
251 +)))
252 +
253 +[[image:image-20220714162600-1.png]]
254 +
255 +(% class="wikigeneratedid" id="HNewPLCproject" %)
256 +(((
257 +**2)New PLC project**
258 +)))
259 +
260 +(((
261 +(((
262 +Click New Project and select the PLC model.
263 +)))
264 +)))
265 +
266 +(((
267 +[[image:image-20220714162617-2.png]]
268 +)))
269 +
270 +(((
271 +
272 +
273 +[[image:image-20220714162652-4.png]]
274 +)))
275 +
276 +(((
277 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
278 +(((
279 +**3)Set Ethernet parameters**
280 +)))
281 +
282 +(((
283 +(((
284 +(((
285 +Follow the steps below to configure Ethernet parameters
286 +)))
287 +)))
288 +)))
289 +
290 +(((
291 +(((
292 +(((
293 +PLC IP address:192.168.40.101
294 +)))
295 +)))
296 +)))
297 +
298 +(((
299 +(((
300 +(((
301 +default gateway:192.168.40.1
302 +)))
303 +)))
304 +)))
305 +
306 +(((
307 +(((
308 +(((
309 +subnet mask:255.255.255.0
310 +)))
311 +)))
312 +)))
313 +
314 +(((
315 +[[image:image-20220714162713-5.png]]
316 +)))
317 +
318 +(((
319 +
320 +)))
321 +
322 +(((
323 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
324 +(((
325 +**V-box software configuration**
326 +)))
327 +
328 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
329 +(((
330 +**1)V-box programming software**
331 +)))
332 +
333 +(% class="wikigeneratedid" %)
334 +(((
335 + [[image:image-20220714162725-6.png]]
336 +)))
337 +
338 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
339 +(((
340 +**2)Configure device network**
341 +)))
342 +
343 +(((
344 +(((
345 +(((
346 +Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
347 +)))
348 +
349 +(((
350 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
351 +)))
352 +)))
353 +)))
354 +
355 +(((
356 +(((
357 +[[image:image-20220714162737-7.png]]
358 +
359 +
360 +)))
361 +)))
362 +)))
363 +)))
364 +
365 +(% class="wikigeneratedid" id="HV-netadddevice" %)
366 +(((
367 +**3)V-net add device**
368 +)))
369 +)))
370 +
371 +(((
372 +(((
373 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
374 +)))
375 +
376 +
377 +)))
378 +
379 +(((
380 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
381 +(((
382 +**4)Set communication port parameters**
383 +)))
384 +
385 +(((
386 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
387 +)))
388 +
389 +[[image:image-20220714162805-9.png]]
390 +)))
391 +
392 +(((
393 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
394 +)))
395 +
396 +[[image:image-20220714162814-10.png]]
397 +
398 +
399 +(((
400 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
401 +)))
402 +
403 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
404 +(((
405 +**5)Engineering production**
406 +)))
407 +
408 +(% class="wikigeneratedid" %)
409 +(((
410 +(((
411 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
412 +)))
413 +
414 +[[image:image-20220714162841-12.png]]
415 +
416 +
417 +(((
418 +**hardware connection**
419 +)))
420 +)))
421 +
422 +(((
423 +**1)Hardware wiring diagram**
424 +)))
425 +
426 +(((
427 +(((
428 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
429 +)))
430 +
431 +[[image:image-20220714162856-13.png]]
432 +
433 +(((
434 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
435 +
436 +
437 +== **Allen-Bradley Ethernet DF1** ==
438 +
439 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
440 +
441 +
442 += **Siemens PLC** =
443 +
444 +== **S7-200 Smart Ethernet Protocol** ==
445 +
446 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
447 +)))
448 +)))
449 +
450 +== **S7-1200 Ethernet Protocol** ==
451 +
452 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
453 +
454 += **Mitsubishi PLC** =
455 +
456 +== **Mitsubishi FX Series Protocol** ==
457 +
458 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
459 +
460 += **Delta PLC** =
461 +
462 +== **DVP Ethernet Protocol** ==
463 +
464 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
465 +
466 +== **DVP Serial Protocol** ==
467 +
468 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
469 +
470 += **Omron PLC** =
471 +
472 +== **CP1 Series Protocol** ==
473 +
474 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
475 +
476 +== **CJ2M Series Protocol** ==
477 +
478 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
479 +
480 += **Modbus RTU** =
481 +
482 +== **V-BOX as master** ==
483 +
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
8 8  
9 9  (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
... ... @@ -11,7 +11,7 @@
11 11  (% style="text-align:center" %)
12 12  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
13 13  
14 -==== V-Box as slave: ====
491 +== **V-BOX as slave** ==
15 15  
16 16  Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
17 17  
... ... @@ -47,59 +47,16 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **1.2 WECON LX3V PLC** ==
527 +== **communicate with VB inverter** ==
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
53 -
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
55 -
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
57 -
58 -(% style="text-align:center" %)
59 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 -
61 -== **1.3 Siemens S7-1200** ==
62 -
63 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
64 -
65 -== **1.4 Allen-Bradley Ethernet DF1** ==
66 -
67 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
68 -
69 -== **1.5 Communication with S7-200 Smart** ==
70 -
71 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
72 -
73 -== **1.6 Delta DVP Ethernet** ==
74 -
75 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
76 -
77 -== **1.7 Delta DVP Serial Protocol** ==
78 -
79 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
80 -
81 -== **1.8 Communicate with Mitsubishi FX Series** ==
82 -
83 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
84 -
85 -== **1.9 Communicate with VB inverter** ==
86 -
87 87  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
88 88  
89 -== **1.10 Omron CP1 Series** ==
531 += **User define protocol** =
90 90  
91 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
533 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
92 92  
93 -== **1.11 Omron CJ2M** ==
535 +== **Read the temperature sensor.** ==
94 94  
95 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
96 -
97 -= **2 User define protocol** =
98 -
99 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
100 -
101 -== **2.1 Read the temperature sensor.** ==
102 -
103 103  the commond format is as beliow:
104 104  
105 105  Send commond:01 03 02 00 00 03 04 73
image-20220714113815-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +907.8 KB
Content
image-20220714113842-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.8 KB
Content
image-20220714113935-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.0 KB
Content
image-20220714114247-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714114257-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +2.0 MB
Content
image-20220714115012-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115214-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.0 MB
Content
image-20220714115308-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +718 bytes
Content
image-20220714115440-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220714115640-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714115848-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB
Content
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content