... ... @@ -1,10 +1,10 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**1)PLC Settings**
7 +**1)V-BOX setting**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,8 +15,9 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**2)PLC Address List**
18 +**2)Address List**
19 19  
20 +
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 22  |Y|Y|Y o|0~~303237|
... ... @@ -35,9 +35,9 @@
35 35  
36 36  **3)Configure the communication protocol**
37 37  
38 -[[image:image-20220824152217-1.png]]
39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
39 39  
40 -**4)hardware connection**
41 +**4)Cable Wiring**
41 41  
42 42  * **RS422**
43 43  
... ... @@ -175,7 +175,7 @@
175 175  
176 176  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
177 177  
178 -= **Rockwell PLC** =
179 += Create communication with **Rockwell PLC** =
179 179  
180 180  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
181 181  
... ... @@ -216,7 +216,7 @@
216 216  
217 217  [[image:image-20220824110724-1.png]]
218 218  
219 -== **CompactLogix Protocol** ==
220 +== **Micro850_FreeTag Protocol** ==
220 220  
221 221  (((
222 222  (((
... ... @@ -355,7 +355,7 @@
355 355  
356 356  (((
357 357  (((
358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 359  )))
360 360  
361 361  
... ... @@ -378,7 +378,7 @@
378 378  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
379 379  )))
380 380  
381 -[[image:image-20220714162814-10.png]]
382 +[[image:image-20220824164346-1.png]]
382 382  
383 383  
384 384  (((
... ... @@ -424,7 +424,7 @@
424 424  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
425 425  
426 426  
427 -= **Siemens PLC** =
428 += Create communication with **Siemens PLC** =
428 428  
429 429  == **S7-200 Smart Ethernet Protocol** ==
430 430  
... ... @@ -431,7 +431,7 @@
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 432  
433 433  
434 -== ** S7-300 Ethernet Protocol** ==
435 +== **S7-300 Ethernet Protocol** ==
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
... ... @@ -483,7 +483,7 @@
483 483  
484 484  [[image:image-20220824161345-1.png]]
485 485  
486 -**Cable Wiring**
487 +**4)Cable Wiring**
487 487  
488 488  [[image:image-20220824161450-2.png]]
489 489  )))
... ... @@ -493,57 +493,787 @@
493 493  
494 494  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
495 495  
496 -= **Mitsubishi PLC** =
497 +== **S7-XXX Ethernet Protocol** ==
497 497  
498 -== **Mitsubishi FX Series Protocol** ==
499 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
500 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
501 +**1)PLC Setting**
501 501  
502 -= **Delta PLC** =
503 +|=**Items**|=**Settings**|=**Note**
504 +|Protocol|Siemens S7-XXX|
505 +|Connection|Ethernet|
506 +|Port No.|102|
507 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
508 +|HMI No.|Rack (Default as 0)|
503 503  
510 +Slot from TIA Portal is equal to Device No. of V-net
511 +
512 +Rack from TIA Portal is equal to HMI No. of V-net
513 +
514 +[[image:image-20220824162459-3.png]]
515 +
516 +[[image:image-20220824163305-2.png]]
517 +
518 +**2)Address List**
519 +
520 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
521 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
522 +d:0~-~-9999
523 +
524 +o:0-7
525 +)))|
526 +|Q|Q|Q d.o|(((
527 +d:0~-~-9999
528 +
529 +o:0-7
530 +)))|
531 +|M|M|M d.o|(((
532 +d:0~-~-9999
533 +
534 +o:0-7
535 +)))|
536 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
537 +nn:0-9999,
538 +
539 +dddd:0-9999,
540 +
541 +o:0-7
542 +)))|(((
543 +nn:DB No.
544 +
545 +dddd:address value
546 +
547 +o: digit address
548 +)))
549 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
550 +|M|MW|MW d|d:0-99999|(((
551 +MW0=MB(0~~1)
552 +
553 +MW2=MB(2~~3)
554 +
555 +Address value is a multiple of 2
556 +)))
557 +|M|MD|MD d|d:0-99999|(((
558 +MD0=MB(0~~3)
559 +
560 +MD4=MB(4~~7)
561 +
562 +Address value is a multiple of 4
563 +)))
564 +|I|IW|IW d|d:0-99999|
565 +|Q|QW|QW d|d:0-99999|
566 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
567 +nn:0-9999
568 +
569 +dddd:0-9999
570 +)))|(((
571 +nn:DB No.
572 +
573 +dddd:address value
574 +)))
575 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
576 +nn:0-9999
577 +
578 +dddd:0-9999
579 +)))|(((
580 +nn:DB No.
581 +
582 +dddd:address value
583 +
584 +Address value is a multiple of 2
585 +)))
586 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
587 +nn:0-9999
588 +
589 +dddd:0-9999
590 +)))|(((
591 +nn:DB No.
592 +
593 +dddd:address value
594 +
595 +Address value is a multiple of 4
596 +)))
597 +
598 +**3)Configure the communication protocol**
599 +
600 +[[image:image-20220824163448-3.png]]
601 +
602 +**✎Note:**
603 +
604 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
605 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
606 +
607 +**4)Cable Wiring**
608 +
609 +[[image:image-20220824162342-2.png]]
610 +
611 += Create communication with **Mitsubishi PLC** =
612 +
613 +== **FX1S,1N,2N Serial Protocol** ==
614 +
615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
616 +
617 +**1)V-BOX Settings**
618 +
619 +|**Item**|**Settings**|**Note**
620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
621 +|Connection|RS422/RS485/RS232|
622 +|Baud rate|9600~~115200|
623 +|Data bit|7/8|
624 +|Parity|EVEN/Odd/None|
625 +|Stop bit|1/2|
626 +|PLC station No.|1~~255|
627 +
628 +**2)Address List**
629 +
630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
632 +|Y|Y|Y o|0~~303237|
633 +|M|M|M d|0~~99999|
634 +|T|T|T d|0~~99999|
635 +|C|C|C d|0~~99999|
636 +|S|S|S d|0~~99999|
637 +|SM|SM|SM d|8000~~9999|
638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
639 +|Y|Y|Y o|0~~303237|
640 +|M|M|M d|0~~99999|
641 +|T|T|T d|0~~99999|
642 +|C|C|C d|0~~199|
643 +|D|D|D d|0~~7999|
644 +|S|S|S d|0~~99999|
645 +|SD|SD|SD d|8000~~9999|
646 +
647 +**3)Configure the communication protocol**
648 +
649 +[[image:image-20220825102844-3.png]]
650 +
651 +**4)Cable Wiring**
652 +
653 +* **RS422**
654 +
655 +[[image:image-20220825103350-4.png]]
656 +
657 +[[image:image-20220825100845-4.png]]
658 +
659 +
660 +== **FX3U,3G,3GA Serial Protocol** ==
661 +
662 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
663 +
664 +**1)V-BOX Settings**
665 +
666 +|**Item**|**Settings**|**Note**
667 +|Protocol|Mitsubishi FX3U/3G/3GA|
668 +|Connection|RS422/RS485/RS232|
669 +|Baud rate|9600~~115200|
670 +|Data bit|7/8|
671 +|Parity|EVEN/Odd/None|
672 +|Stop bit|1/2|
673 +|PLC station No.|1~~255|
674 +
675 +**2)Address List**
676 +
677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
678 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
679 +|Y|Y|Y o|0~~303237|
680 +|M|M|M d|0~~99999|
681 +|T|T|T d|0~~99999|
682 +|C|C|C d|0~~99999|
683 +|S|S|S d|0~~99999|
684 +|SM|SM|SM d|8000~~9999|
685 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
686 +|Y|Y|Y o|0~~303237|
687 +|M|M|M d|0~~99999|
688 +|T|T|T d|0~~99999|
689 +|C|C|C d|0~~199|
690 +|D|D|D d|0~~7999|
691 +|S|S|S d|0~~99999|
692 +|SD|SD|SD d|8000~~9999|
693 +
694 +**3)Configure the communication protocol**
695 +
696 +[[image:image-20220825102649-2.png]]
697 +
698 +**4)Cable Wiring**
699 +
700 +* **RS422**
701 +
702 +[[image:image-20220825103421-5.png]]
703 +
704 +[[image:image-20220825100845-4.png]]
705 +
706 +
707 +== **FX5U Serial Protocol** ==
708 +
709 +Mitsubishi FX5U series PLC
710 +
711 +**1)V-BOX Settings**
712 +
713 +|**Item**|**Settings**|**Note**
714 +|Protocol|Mitsubishi FX5U|
715 +|Connection|RS422/RS485|
716 +|Baud rate|9600|
717 +|Data bit|7|
718 +|Parity|Odd|
719 +|Stop bit|1|
720 +|PLC station No.|1~~255|Need to be the same as PLC settings
721 +
722 +**2)Address List**
723 +
724 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
725 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
726 +|Y|Y|Y o|0~~303237|
727 +|M|M|M d|0~~99999|
728 +|B|B|B h|0~~7FFF|
729 +|F|F|F d|0~~32767|
730 +|SB|SB|SB h|0~~7FFF|
731 +|TS|TS|TS d|0~~1023|
732 +|TC|TC|TC d|0~~1023|
733 +|STS|STS|STS d|0~~1023|
734 +|STC|STC|STS d|0~~1023|
735 +|CS|CS|CS d|0~~1023|
736 +|CC|CC|CC d|0~~1023|
737 +|SM|SM|SM d|0~~9999|
738 +|L|L|L d|0~~32767|
739 +|S|S|S d|0~~4095|
740 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
741 +|TN|TN|TN d|0~~1023|
742 +|STN|STN|STN d|0~~1023|
743 +|CN|CN|CN d|0~~1023|
744 +|R|R|R d|0~~32767|
745 +|SW|SW|SW h|0~~7FFF|
746 +|Z|Z|Z d|0~~23|
747 +|D|D|D d|0~~7999|
748 +|SD|SD|SD d|0~~11999|
749 +
750 +**3)PLC Settings (GX Works 3)**
751 +
752 +Create a blank FX5U project
753 +
754 +Find the 485 serial port module in the system navigation bar and double click to enter the settings.
755 +
756 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
757 +
758 +Select protocol in the setting item, and set parameters.
759 +
760 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
761 +
762 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
763 +
764 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
765 +
766 +Click the [Apply] button to finish the setting.
767 +
768 +Click download and select the items as below, then click [execute] to download the configuration to PLC.
769 +
770 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
771 +
772 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
773 +
774 +Done.
775 +
776 +**4)Configure the communication protocol**
777 +
778 +[[image:image-20220825104904-1.png]]
779 +
780 +**5)Cable Wiring**
781 +
782 +
783 +* **RS422**
784 +
785 +[[image:image-20220825105105-2.png]]
786 +
787 +[[image:image-20220825105533-3.png]]
788 +
789 +== **FX5U Ethernet Protocol** ==
790 +
791 +Mitsubishi FX5U series PLC
792 +
793 +**1)V-BOX Settings**
794 +
795 +|**Items**|**Settings**|**Note**
796 +|Protocol|Mitsubishi FX5U|
797 +|Connection|Ethernet|
798 +|Port No.|5002|Must be the same as the PLC setting
799 +|PLC station No.|0|
800 +
801 +**2)Address List**
802 +
803 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
804 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
805 +|Y|Y|Y o|0~~303237|
806 +|M|M|M d|0~~99999|
807 +|B|B|B h|0~~7FFF|
808 +|F|F|F d|0~~32767|
809 +|SB|SB|SB h|0~~7FFF|
810 +|TS|TS|TS d|0~~1023|
811 +|TC|TC|TC d|0~~1023|
812 +|STS|STS|STS d|0~~1023|
813 +|STC|STC|STS d|0~~1023|
814 +|CS|CS|CS d|0~~1023|
815 +|CC|CC|CC d|0~~1023|
816 +|SM|SM|SM d|0~~9999|
817 +|L|L|L d|0~~32767|
818 +|S|S|S d|0~~4095|
819 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
820 +|TN|TN|TN d|0~~1023|
821 +|STN|STN|STN d|0~~1023|
822 +|CN|CN|CN d|0~~1023|
823 +|R|R|R d|0~~32767|
824 +|SW|SW|SW h|0~~7FFF|
825 +|Z|Z|Z d|0~~23|
826 +|D|D|D d|0~~7999|
827 +|SD|SD|SD d|0~~11999|
828 +
829 +**3)PLC Settings (GX Works 3)**
830 +
831 +Find the [Ethernet port] in the navigation area.
832 +
833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
834 +
835 +Select [Own Node Settings] in the [Setting Item List];
836 +
837 +Set [IP Address], [Subnet Mask], [Default Gateway];
838 +
839 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
840 +
841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
842 +
843 +Select [SLMP Connection Module] and add into host station as below picture shows;
844 +
845 +Set Port number as 5002 (this is necessary settings);
846 +
847 +Click [Close with Reflecting the Setting] to save and close window;
848 +
849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
850 +
851 +Click [Apply] to completed Etherenet settings;
852 +
853 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
854 +
855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
856 +
857 +**4)Configure the communication protocol**
858 +
859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
860 +
861 +**5)电缆布线**
862 +
863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 +
865 +
866 +== **L02 Serial Protocol** ==
867 +
868 +Mitsubishi L02 series CPU built-in serial port.
869 +
870 +**1)V-BOX Settings**
871 +
872 +|**Item**|**Settings**|**Note**
873 +|Protocol|Mitsubishi L02|
874 +|Connection|RS422|
875 +|Baud rate|115200|
876 +|Data bit|8|
877 +|Parity|Odd|
878 +|Stop bit|1|
879 +|PLC station No.|1~~255|Need to be the same as PLC settings
880 +
881 +**2)Address List**
882 +
883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
884 +|Bit|X|X|X h|0~~FFFF|
885 +|Bit|Y|Y|Y h|0~~FFFF|
886 +|Bit|M|M|M d|0~~9999|
887 +|Bit|L|L|L d|0~~9999|
888 +|Bit|F|F|F d|0~~9999|
889 +|Bit|B|B|B h|0~~FFFF|
890 +|Bit|V|V|V d|0~~2047|
891 +|Bit|TC|TC|TC d|0~~9999|
892 +|Bit|SS|SS|SS d|0~~9999|
893 +|Bit|SC|SC|SC d|0~~9999|
894 +|Bit|CS|CS|CS d|0~~9999|
895 +|Bit|CC|CC|CC d|0~~9999|
896 +|Bit|SB|SB|SB h|0~~FFFF|
897 +|Bit|SM|SM|SM d|0~~2047|
898 +|Bit|STS|STS|STS d|0~~1023|
899 +|Bit|S|S|S d|0~~9999|
900 +|Bit|DX|DX|DX h|0~~FFFF|
901 +|Bit|DY|DY|DY h|0~~FFFF|
902 +|Bit|TS|TS|TS d|0~~9999|
903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
904 +|Word|W|W|W h|0~~FFFF|
905 +|Word|TN|TN|TN d|0~~99999|
906 +|Word|SN|SN|SN d|0~~99999|
907 +|Word|CN|CN|CN d|0~~99999|
908 +|Word|R|R|R d|0~~99999|
909 +|Word|SW|SW|SW h|0~~FFFF|
910 +|Word|Z|Z|Z d|0~~99999|
911 +|Word|ZR|ZR|ZR h|0~~FFFF|
912 +|Word|D|D|D d|0~~99999|
913 +
914 +**3)Communication Settings**
915 +
916 +[[image:image-20220825160648-3.png]]
917 +
918 +**4)Cable Wiring**
919 +
920 +* **RS422**
921 +
922 +[[image:image-20220825161612-8.png]]
923 +
924 +[[image:image-20220825160820-4.png]]
925 +
926 +== **L02 Ethernet Protocol** ==
927 +
928 +Mitsubishi L series CPU built-in Ethernet port.
929 +
930 +**1)V-BOX Settings**
931 +
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|MIT L02 CPU MELSEC|
934 +|Connection|Ethernet|
935 +|Port No.|1025|Must be the same as the PLC setting
936 +|PLC station No.|0|Must be the same as the PLC setting
937 +
938 +**2)Address List**
939 +
940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
941 +|Bit|X|X|X h|0~~FFFF|
942 +|Bit|Y|Y|Y h|0~~FFFF|
943 +|Bit|M|M|M d|0~~9999|
944 +|Bit|L|L|L d|0~~9999|
945 +|Bit|F|F|F d|0~~9999|
946 +|Bit|B|B|B h|0~~FFFF|
947 +|Bit|V|V|V d|0~~2047|
948 +|Bit|TC|TC|TC d|0~~9999|
949 +|Bit|SS|SS|SS d|0~~9999|
950 +|Bit|SC|SC|SC d|0~~9999|
951 +|Bit|CS|CS|CS d|0~~9999|
952 +|Bit|CC|CC|CC d|0~~9999|
953 +|Bit|SB|SB|SB h|0~~FFFF|
954 +|Bit|SM|SM|SM d|0~~2047|
955 +|Bit|STS|STS|STS d|0~~1023|
956 +|Bit|S|S|S d|0~~9999|
957 +|Bit|DX|DX|DX h|0~~FFFF|
958 +|Bit|DY|DY|DY h|0~~FFFF|
959 +|Bit|TS|TS|TS d|0~~9999|
960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
961 +|Word|W|W|W h|0~~FFFF|
962 +|Word|TN|TN|TN d|0~~99999|
963 +|Word|SN|SN|SN d|0~~99999|
964 +|Word|CN|CN|CN d|0~~99999|
965 +|Word|R|R|R d|0~~99999|
966 +|Word|SW|SW|SW h|0~~FFFF|
967 +|Word|Z|Z|Z d|0~~99999|
968 +|Word|ZR|ZR|ZR h|0~~FFFF|
969 +|Word|D|D|D d|0~~99999|
970 +
971 +**3)PLC Settings (GX Works2 )**
972 +
973 +Create a project
974 +
975 +Set PLC IP, subnet mask and gateway;
976 +
977 +Select [Binary Code] as communication data code;
978 +
979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
980 +
981 +Set PLC port number, for example 1025
982 +
983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
984 +
985 +Save settings;
986 +
987 +Download project into PLC device;
988 +
989 +Restart PLC device;
990 +
991 +**4)Configure the communication protocol**
992 +
993 +[[image:image-20220825142659-1.png]]
994 +
995 +**5)Cable Wiring**
996 +
997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
998 +
999 +== **QJ71E71 Ethernet Protocol** ==
1000 +
1001 +Mitsubishi QJ71E71 Ethernet communication module;
1002 +
1003 +**1)V-BOX Settings**
1004 +
1005 +|**Items**|**Settings**|**Note**
1006 +|Protocol|MIT QJ71E71 MELSEC|
1007 +|Connection|Ethernet|
1008 +|Port No.|1025|Must be the same as the PLC setting
1009 +|PLC station No.|0|Must be the same as the PLC setting
1010 +
1011 +**2)Address List**
1012 +
1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1015 +|Y|Y|Y h|0~~1FFF|
1016 +|M|M|M d|0~~99999|
1017 +|L|L|L d|0~~8191|
1018 +|F|F|F d|0~~2047|
1019 +|B|B|B h|0~~1FFF|
1020 +|V|V|V d|0~~2047|
1021 +|TS|TS|TS d|0~~2047|
1022 +|TC|TC|TC d|0~~2047|
1023 +|SS|SS|SS d|0~~2047|
1024 +|SC|SC|SC d|0~~2047|
1025 +|CS|CS|CS d|0~~1023|
1026 +|CC|CC|CC d|0~~1023|
1027 +|SB|SB|SB h|0~~7FF|
1028 +|S|S|S d|0~~8191|
1029 +|DX|DX|DX h|0~~1FFF|
1030 +|DY|DY|DY h|0~~1FFF|
1031 +|SM|SM|SM d|8000~~9999|
1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1033 +|D|D|D d|0~~12287|
1034 +|W|W|W h|0~~1FFF|
1035 +|TN|TN|TN d|0~~2047|
1036 +|SN|SN|SN d|0~~2047|
1037 +|CN|CN|CN d|0~~1023|
1038 +|R|R|R d|0~~32767|
1039 +|SW|SW|SW h|0~~7FF|
1040 +|Z|Z|Z d|0~~15|
1041 +|ZR|ZR|ZR h|0~~FE7FF|
1042 +
1043 +**3)PLC Settings(GX Works2)**
1044 +
1045 +* Click [Ethernet/CC IE/MELSECNET];
1046 +* Please select [Ethernet] as network type;
1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1048 +* Select [Online] as Mode;
1049 +* Click [Operation setting] to set IP;
1050 +* Select [Binary Code] as [Communication Data Code];
1051 +* Set protocol: TCP;
1052 +* Set [unpassive] in [Open system];
1053 +* Set [receive] in [Fixed buffer];
1054 +* Set [procedure Exist] in [Fixed buffer communication];
1055 +* Disable [Pairing open];
1056 +* Set [No confirm] in [Existence confirmation];
1057 +* Host station port number: 1025;
1058 +* Save settings;
1059 +* Download project into PLC and restart it
1060 +
1061 +**4)Configure the communication protocol**
1062 +
1063 +[[image:image-20220825143728-1.png]]
1064 +
1065 +**5)Cable Wiring**
1066 +
1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1068 +
1069 += Create communication with **Delta PLC** =
1070 +
504 504  == **DVP Ethernet Protocol** ==
505 505  
506 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
507 507  
508 -== **DVP Serial Protocol** ==
1075 +== **DVP serial protocol** ==
509 509  
510 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
511 511  
512 -= **Omron PLC** =
1079 +== **AS Ethernet Protocol** ==
513 513  
514 -== **CP1 Series Protocol** ==
1081 +**1)V-BOX Settings**
515 515  
516 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1083 +|=**Items**|=**Settings**|=**Note**
1084 +|Protocol|DELTA AS300 MODBUS TCP|
1085 +|Connection|Ethernet|
1086 +|Port No.|502|
1087 +|Device No.|1|
1088 +|HMI No.|0|
517 517  
518 -== **CJ2M Series Protocol** ==
1090 +**2)Address List**
519 519  
520 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1093 +|Bit|X|X|X d|0~~63|
1094 +|Bit|Y|Y|Y d|0~~63|
1095 +|Bit|D|D|D d|0~~29999|
1096 +|Bit|M|M|M d|0~~8191|
1097 +|Bit|SM|SM|SM d|0~~4095|
1098 +|Bit|S|S|S h|0~~2047|
1099 +|Bit|T|T|T d|0~~511|
1100 +|Bit|C|C|C d|0~~511|
1101 +|Bit|HC|HC|HC d|0~~255|
1102 +|Word|X|X|X h|0~~63|
1103 +|Word|Y|Y|Y d|0~~63|
1104 +|Word|SR|SR|SR d|0~~2047|
1105 +|Word|D|D|D d|0~~29999|
1106 +|Word|T|T|T d|0~~511|
1107 +|Word|C|C|C h|0~~511|
1108 +|Word|E|E|E d|0~~9|
521 521  
522 -= **Modbus RTU** =
1110 +**3)Configure the communication protocol**
523 523  
524 -== **V-BOX as master** ==
525 525  
526 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
1113 +[[image:image-20220831160010-4.png]]
527 527  
528 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1115 +**4)Cable Wiring**
529 529  
1117 +Figure
1118 +
1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1120 +
1121 +Pin Definition Diagram
1122 +
1123 +[[image:image-20220831155157-3.png]]
1124 +
1125 += Create communication with **Omron PLC** =
1126 +
1127 +== **CP1 Series Protocol ** ==
1128 +
1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1130 +
1131 +== **CP2M Series Protocol** ==
1132 +
1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1134 +
1135 +
1136 +== **EC55 Series Protocol** ==
1137 +
1138 +Supported device: EC55 temperature instrument
1139 +
1140 +**1)V-BOX Settings**
1141 +
1142 +|**Items**|**Settings**|**Note**
1143 +|Protocol|Omron EC55|
1144 +|Connection|RS485 (9600, 2, 7, EVEN)|
1145 +|Port No.|None|
1146 +|PLC station No.|0|
1147 +
1148 +**2)Address List**
1149 +
1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1157 +|CP|-|0-6|Read controller intrinsic property
1158 +|CS|-|0-2|Read controller states
1159 +|CA|-|0-17|Action command
1160 +
1161 +**3)Device Settings**
1162 +
1163 +Omron E5CC PLC configuration
1164 +
1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1166 +
1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1168 +
1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1170 +
1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1172 +
1173 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1174 +
1175 +**4)Configure the communication protocol**
1176 +
1177 +[[image:image-20220831161041-1.png]]
1178 +
1179 +**5)Cable Wiring**
1180 +
1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1182 +
1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1184 +
1185 +**✎Note:**
1186 +
1187 +* COM3 only available in PI8000/PI9000 series.
1188 +* CA address could not support continuous writing function;
1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1195 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1196 +
1197 +== **EtherNet/IP NX series Protocol** ==
1198 +
1199 +Supported series: Omron NX/NJ series
1200 +
1201 +**HMI Setting**
1202 +
1203 +|**Items**|**Settings**|**Note**
1204 +|Protocol|Omron NX Ethernet/IP|
1205 +|Connection|Ethernet|
1206 +|Port No.|44818|
1207 +|PLC station No.|1|
1208 +
1209 +**Instruction**
1210 +
1211 +1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
1212 +
1213 +2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
1214 +
1215 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4156caf6f116c570.png?width=600&height=277&rev=1.1||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]]
1216 +
1217 +**Export labels from Sysmac Studio**
1218 +
1219 +Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
1220 +
1221 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_26f91dee66c723e9.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]]
1222 +
1223 +Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol;
1224 +
1225 +Click [Label manage];
1226 +
1227 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cd38d2d0c5187f6b.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]]
1228 +
1229 +Click [Import labels] and then select the file exported in step 1;
1230 +
1231 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_52bd5da678bef9b4.png?width=600&height=403&rev=1.1||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]]
1232 +
1233 +The Import Status field shows the result, click [OK] to finish importing address labels;
1234 +
1235 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_7f0465a589b98912.png?width=600&height=291&rev=1.1||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]]
1236 +
1237 +**Communication Settings**
1238 +
1239 +Enable HMI Ethernet in [Project Settings];
1240 +
1241 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1242 +
1243 +Set PLC IP in [Device IP] settings;
1244 +
1245 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_437cb087b36b5784.png?width=600&height=330&rev=1.1||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]]
1246 +
1247 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60ef71528a99abf5.png?width=554&height=188&rev=1.1||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]]
1248 +
1249 +**Cable Wiring**
1250 +
1251 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1252 +
1253 += Create communication with **Modbus RTU** =
1254 +
1255 +== **V-BOX as Slave** ==
1256 +
1257 +Select the protocol "Modbus RTU Slave (All Fuction)",
1258 +
1259 +Then set baud rate, port, stop bits, data bits, parity.
1260 +
530 530  (% style="text-align:center" %)
531 531  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
532 532  
533 -== **V-BOX as slave** ==
1264 +== **V-BOX as Master** ==
534 534  
535 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
1266 +Select the protocol "Modbus RTU Master",
536 536  
537 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1268 +Then set baud rate, port, stop bits, data bits, parity
538 538  
539 539  (% style="text-align:center" %)
540 540  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
541 541  
542 -**Address List**
1273 +**address list**
543 543  
544 544  (% class="table-bordered" %)
545 -|**Type**|**Register**|**Function code & Description**
546 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1276 +|**type**|**register**|**Function code and description**
1277 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
547 547  |06 (write single register: write a binary value to a holding register)
548 548  |10 (write values to multiple addresses )
549 549  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
image-20220824162339-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162342-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
image-20220824162459-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
image-20220824163110-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content
image-20220824164346-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.2 KB
Content
image-20220825100807-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100814-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100845-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content
image-20220825102641-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102649-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
image-20220825102844-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.8 KB
Content
image-20220825103350-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
image-20220825103421-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.0 KB
Content
image-20220825104904-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
image-20220825105105-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
image-20220825105533-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content