Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 37 added, 0 removed)
- image-20220824162339-1.png
- image-20220824162342-2.png
- image-20220824162459-3.png
- image-20220824163110-1.png
- image-20220824163305-2.png
- image-20220824163448-3.png
- image-20220824164346-1.png
- image-20220825100807-1.png
- image-20220825100814-3.png
- image-20220825100845-4.png
- image-20220825102641-1.png
- image-20220825102649-2.png
- image-20220825102844-3.png
- image-20220825103350-4.png
- image-20220825103421-5.png
- image-20220825104904-1.png
- image-20220825105105-2.png
- image-20220825105533-3.png
- image-20220825112403-1.png
- image-20220825142437-1.png
- image-20220825142659-1.png
- image-20220825143728-1.png
- image-20220825160227-1.png
- image-20220825160341-2.png
- image-20220825160648-3.png
- image-20220825160820-4.png
- image-20220825160925-5.png
- image-20220825160929-6.png
- image-20220825161440-7.png
- image-20220825161612-8.png
- image-20220831155101-1.png
- image-20220831155129-2.png
- image-20220831155157-3.png
- image-20220831160010-4.png
- image-20220831160055-5.png
- image-20220831161041-1.png
- image-20220831161356-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,10 @@ 1 -= (% style="color:inherit; font-family:inherit"%)**WECON PLC**(%%)=1 += Create communication with WECON PLC = 2 2 3 -== **LX3V 3 +== **LX3V Serial Protocol** == 4 4 5 -Supported series: W ECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) PLCSettings**7 +**1)V-BOX setting** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,8 +15,9 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**2) PLCAddress List**18 +**2)Address List** 19 19 20 + 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 22 22 |Y|Y|Y o|0~~303237| ... ... @@ -35,9 +35,9 @@ 35 35 36 36 **3)Configure the communication protocol** 37 37 38 -[[image:image-20220824152217-1.png]] 39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] 39 39 40 -**4) hardwareconnection**41 +**4)Cable Wiring** 41 41 42 42 * **RS422** 43 43 ... ... @@ -175,7 +175,7 @@ 175 175 176 176 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 177 177 178 -= **Rockwell PLC** = 179 += Create communication with **Rockwell PLC** = 179 179 180 180 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 181 181 ... ... @@ -216,7 +216,7 @@ 216 216 217 217 [[image:image-20220824110724-1.png]] 218 218 219 -== ** CompactLogixProtocol** ==220 +== **Micro850_FreeTag Protocol** == 220 220 221 221 ((( 222 222 ((( ... ... @@ -355,7 +355,7 @@ 355 355 356 356 ((( 357 357 ((( 358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 359 359 ))) 360 360 361 361 ... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]382 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -424,7 +424,7 @@ 424 424 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 425 425 426 426 427 -= **Siemens PLC** = 428 += Create communication with **Siemens PLC** = 428 428 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 435 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -**Cable Wiring** 487 +**4)Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -493,11 +493,11 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== ** 497 +== **S7-XXX Ethernet Protocol** == 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 500 -** HMISetting**501 +**1)PLC Setting** 501 501 502 502 |=**Items**|=**Settings**|=**Note** 503 503 |Protocol|Siemens S7-XXX| ... ... @@ -506,17 +506,15 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of PIStudio510 +Slot from TIA Portal is equal to Device No. of V-net 510 510 511 -Rack from TIA Portal is equal to HMI No. of PIStudio512 +Rack from TIA Portal is equal to HMI No. of V-net 512 512 513 -(% style="text-align:center" %) 514 -[[image:S7-XXXCommunication Settings.png]] 514 +[[image:image-20220824162459-3.png]] 515 515 516 -(% style="text-align:center" %) 517 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 516 +[[image:image-20220824163305-2.png]] 518 518 519 -**Address List** 518 +**2)Address List** 520 520 521 521 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 522 522 |(% rowspan="4" %)Bit|I|I|M d.o|((( ... ... @@ -596,79 +596,1118 @@ 596 596 Address value is a multiple of 4 597 597 ))) 598 598 599 -**Communication Settings**598 +**3)Configure the communication protocol** 600 600 600 +[[image:image-20220824163448-3.png]] 601 + 602 +**✎Note:** 603 + 604 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 605 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 606 + 607 +**4)Cable Wiring** 608 + 609 +[[image:image-20220824162342-2.png]] 610 + 611 += Create communication with **Mitsubishi PLC** = 612 + 613 +== **FX1S,1N,2N Serial Protocol** == 614 + 615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 616 + 617 +**1)V-BOX Settings** 618 + 619 +|**Item**|**Settings**|**Note** 620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 621 +|Connection|RS422/RS485/RS232| 622 +|Baud rate|9600~~115200| 623 +|Data bit|7/8| 624 +|Parity|EVEN/Odd/None| 625 +|Stop bit|1/2| 626 +|PLC station No.|1~~255| 627 + 628 +**2)Address List** 629 + 630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 632 +|Y|Y|Y o|0~~303237| 633 +|M|M|M d|0~~99999| 634 +|T|T|T d|0~~99999| 635 +|C|C|C d|0~~99999| 636 +|S|S|S d|0~~99999| 637 +|SM|SM|SM d|8000~~9999| 638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|T|T|T d|0~~99999| 642 +|C|C|C d|0~~199| 643 +|D|D|D d|0~~7999| 644 +|S|S|S d|0~~99999| 645 +|SD|SD|SD d|8000~~9999| 646 + 647 +**3)Configure the communication protocol** 648 + 649 +[[image:image-20220825102844-3.png]] 650 + 651 +**4)Cable Wiring** 652 + 653 +* **RS422** 654 + 655 +[[image:image-20220825103350-4.png]] 656 + 657 +[[image:image-20220825100845-4.png]] 658 + 659 + 660 +== **FX3U,3G,3GA Serial Protocol** == 661 + 662 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 663 + 664 +**1)V-BOX Settings** 665 + 666 +|**Item**|**Settings**|**Note** 667 +|Protocol|Mitsubishi FX3U/3G/3GA| 668 +|Connection|RS422/RS485/RS232| 669 +|Baud rate|9600~~115200| 670 +|Data bit|7/8| 671 +|Parity|EVEN/Odd/None| 672 +|Stop bit|1/2| 673 +|PLC station No.|1~~255| 674 + 675 +**2)Address List** 676 + 677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 678 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 679 +|Y|Y|Y o|0~~303237| 680 +|M|M|M d|0~~99999| 681 +|T|T|T d|0~~99999| 682 +|C|C|C d|0~~99999| 683 +|S|S|S d|0~~99999| 684 +|SM|SM|SM d|8000~~9999| 685 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 686 +|Y|Y|Y o|0~~303237| 687 +|M|M|M d|0~~99999| 688 +|T|T|T d|0~~99999| 689 +|C|C|C d|0~~199| 690 +|D|D|D d|0~~7999| 691 +|S|S|S d|0~~99999| 692 +|SD|SD|SD d|8000~~9999| 693 + 694 +**3)Configure the communication protocol** 695 + 696 +[[image:image-20220825102649-2.png]] 697 + 698 +**4)Cable Wiring** 699 + 700 +* **RS422** 701 + 702 +[[image:image-20220825103421-5.png]] 703 + 704 +[[image:image-20220825100845-4.png]] 705 + 706 + 707 +== **FX5U Serial Protocol** == 708 + 709 +Mitsubishi FX5U series PLC 710 + 711 +**1)V-BOX Settings** 712 + 713 +|**Item**|**Settings**|**Note** 714 +|Protocol|Mitsubishi FX5U| 715 +|Connection|RS422/RS485| 716 +|Baud rate|9600| 717 +|Data bit|7| 718 +|Parity|Odd| 719 +|Stop bit|1| 720 +|PLC station No.|1~~255|Need to be the same as PLC settings 721 + 722 +**2)Address List** 723 + 724 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 725 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 726 +|Y|Y|Y o|0~~303237| 727 +|M|M|M d|0~~99999| 728 +|B|B|B h|0~~7FFF| 729 +|F|F|F d|0~~32767| 730 +|SB|SB|SB h|0~~7FFF| 731 +|TS|TS|TS d|0~~1023| 732 +|TC|TC|TC d|0~~1023| 733 +|STS|STS|STS d|0~~1023| 734 +|STC|STC|STS d|0~~1023| 735 +|CS|CS|CS d|0~~1023| 736 +|CC|CC|CC d|0~~1023| 737 +|SM|SM|SM d|0~~9999| 738 +|L|L|L d|0~~32767| 739 +|S|S|S d|0~~4095| 740 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 741 +|TN|TN|TN d|0~~1023| 742 +|STN|STN|STN d|0~~1023| 743 +|CN|CN|CN d|0~~1023| 744 +|R|R|R d|0~~32767| 745 +|SW|SW|SW h|0~~7FFF| 746 +|Z|Z|Z d|0~~23| 747 +|D|D|D d|0~~7999| 748 +|SD|SD|SD d|0~~11999| 749 + 750 +**3)PLC Settings (GX Works 3)** 751 + 752 +Create a blank FX5U project 753 + 754 +Find the 485 serial port module in the system navigation bar and double click to enter the settings. 755 + 756 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 757 + 758 +Select protocol in the setting item, and set parameters. 759 + 760 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 761 + 762 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 763 + 764 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 765 + 766 +Click the [Apply] button to finish the setting. 767 + 768 +Click download and select the items as below, then click [execute] to download the configuration to PLC. 769 + 770 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 771 + 772 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 773 + 774 +Done. 775 + 776 +**4)Configure the communication protocol** 777 + 778 +[[image:image-20220825104904-1.png]] 779 + 780 +**5)Cable Wiring** 781 + 782 + 783 +* **RS422** 784 + 785 +[[image:image-20220825105105-2.png]] 786 + 787 +[[image:image-20220825105533-3.png]] 788 + 789 +== **FX5U Ethernet Protocol** == 790 + 791 +Mitsubishi FX5U series PLC 792 + 793 +**1)V-BOX Settings** 794 + 795 +|**Items**|**Settings**|**Note** 796 +|Protocol|Mitsubishi FX5U| 797 +|Connection|Ethernet| 798 +|Port No.|5002|Must be the same as the PLC setting 799 +|PLC station No.|0| 800 + 801 +**2)Address List** 802 + 803 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 804 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 805 +|Y|Y|Y o|0~~303237| 806 +|M|M|M d|0~~99999| 807 +|B|B|B h|0~~7FFF| 808 +|F|F|F d|0~~32767| 809 +|SB|SB|SB h|0~~7FFF| 810 +|TS|TS|TS d|0~~1023| 811 +|TC|TC|TC d|0~~1023| 812 +|STS|STS|STS d|0~~1023| 813 +|STC|STC|STS d|0~~1023| 814 +|CS|CS|CS d|0~~1023| 815 +|CC|CC|CC d|0~~1023| 816 +|SM|SM|SM d|0~~9999| 817 +|L|L|L d|0~~32767| 818 +|S|S|S d|0~~4095| 819 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 820 +|TN|TN|TN d|0~~1023| 821 +|STN|STN|STN d|0~~1023| 822 +|CN|CN|CN d|0~~1023| 823 +|R|R|R d|0~~32767| 824 +|SW|SW|SW h|0~~7FFF| 825 +|Z|Z|Z d|0~~23| 826 +|D|D|D d|0~~7999| 827 +|SD|SD|SD d|0~~11999| 828 + 829 +**3)PLC Settings (GX Works 3)** 830 + 831 +Find the [Ethernet port] in the navigation area. 832 + 833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 834 + 835 +Select [Own Node Settings] in the [Setting Item List]; 836 + 837 +Set [IP Address], [Subnet Mask], [Default Gateway]; 838 + 839 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 840 + 841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 842 + 843 +Select [SLMP Connection Module] and add into host station as below picture shows; 844 + 845 +Set Port number as 5002 (this is necessary settings); 846 + 847 +Click [Close with Reflecting the Setting] to save and close window; 848 + 849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 850 + 851 +Click [Apply] to completed Etherenet settings; 852 + 853 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 854 + 855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 856 + 857 +**4)Configure the communication protocol** 858 + 859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 + 861 +**5)电缆布线** 862 + 863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 + 865 + 866 +== **L02 Serial Protocol** == 867 + 868 +Mitsubishi L02 series CPU built-in serial port. 869 + 870 +**1)V-BOX Settings** 871 + 872 +|**Item**|**Settings**|**Note** 873 +|Protocol|Mitsubishi L02| 874 +|Connection|RS422| 875 +|Baud rate|115200| 876 +|Data bit|8| 877 +|Parity|Odd| 878 +|Stop bit|1| 879 +|PLC station No.|1~~255|Need to be the same as PLC settings 880 + 881 +**2)Address List** 882 + 883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 884 +|Bit|X|X|X h|0~~FFFF| 885 +|Bit|Y|Y|Y h|0~~FFFF| 886 +|Bit|M|M|M d|0~~9999| 887 +|Bit|L|L|L d|0~~9999| 888 +|Bit|F|F|F d|0~~9999| 889 +|Bit|B|B|B h|0~~FFFF| 890 +|Bit|V|V|V d|0~~2047| 891 +|Bit|TC|TC|TC d|0~~9999| 892 +|Bit|SS|SS|SS d|0~~9999| 893 +|Bit|SC|SC|SC d|0~~9999| 894 +|Bit|CS|CS|CS d|0~~9999| 895 +|Bit|CC|CC|CC d|0~~9999| 896 +|Bit|SB|SB|SB h|0~~FFFF| 897 +|Bit|SM|SM|SM d|0~~2047| 898 +|Bit|STS|STS|STS d|0~~1023| 899 +|Bit|S|S|S d|0~~9999| 900 +|Bit|DX|DX|DX h|0~~FFFF| 901 +|Bit|DY|DY|DY h|0~~FFFF| 902 +|Bit|TS|TS|TS d|0~~9999| 903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 904 +|Word|W|W|W h|0~~FFFF| 905 +|Word|TN|TN|TN d|0~~99999| 906 +|Word|SN|SN|SN d|0~~99999| 907 +|Word|CN|CN|CN d|0~~99999| 908 +|Word|R|R|R d|0~~99999| 909 +|Word|SW|SW|SW h|0~~FFFF| 910 +|Word|Z|Z|Z d|0~~99999| 911 +|Word|ZR|ZR|ZR h|0~~FFFF| 912 +|Word|D|D|D d|0~~99999| 913 + 914 +**3)Communication Settings** 915 + 916 +[[image:image-20220825160648-3.png]] 917 + 918 +**4)Cable Wiring** 919 + 920 +* **RS422** 921 + 922 +[[image:image-20220825161612-8.png]] 923 + 924 +[[image:image-20220825160820-4.png]] 925 + 926 +== **L02 Ethernet Protocol** == 927 + 928 +Mitsubishi L series CPU built-in Ethernet port. 929 + 930 +**1)V-BOX Settings** 931 + 932 +|**Items**|**Settings**|**Note** 933 +|Protocol|MIT L02 CPU MELSEC| 934 +|Connection|Ethernet| 935 +|Port No.|1025|Must be the same as the PLC setting 936 +|PLC station No.|0|Must be the same as the PLC setting 937 + 938 +**2)Address List** 939 + 940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 941 +|Bit|X|X|X h|0~~FFFF| 942 +|Bit|Y|Y|Y h|0~~FFFF| 943 +|Bit|M|M|M d|0~~9999| 944 +|Bit|L|L|L d|0~~9999| 945 +|Bit|F|F|F d|0~~9999| 946 +|Bit|B|B|B h|0~~FFFF| 947 +|Bit|V|V|V d|0~~2047| 948 +|Bit|TC|TC|TC d|0~~9999| 949 +|Bit|SS|SS|SS d|0~~9999| 950 +|Bit|SC|SC|SC d|0~~9999| 951 +|Bit|CS|CS|CS d|0~~9999| 952 +|Bit|CC|CC|CC d|0~~9999| 953 +|Bit|SB|SB|SB h|0~~FFFF| 954 +|Bit|SM|SM|SM d|0~~2047| 955 +|Bit|STS|STS|STS d|0~~1023| 956 +|Bit|S|S|S d|0~~9999| 957 +|Bit|DX|DX|DX h|0~~FFFF| 958 +|Bit|DY|DY|DY h|0~~FFFF| 959 +|Bit|TS|TS|TS d|0~~9999| 960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 961 +|Word|W|W|W h|0~~FFFF| 962 +|Word|TN|TN|TN d|0~~99999| 963 +|Word|SN|SN|SN d|0~~99999| 964 +|Word|CN|CN|CN d|0~~99999| 965 +|Word|R|R|R d|0~~99999| 966 +|Word|SW|SW|SW h|0~~FFFF| 967 +|Word|Z|Z|Z d|0~~99999| 968 +|Word|ZR|ZR|ZR h|0~~FFFF| 969 +|Word|D|D|D d|0~~99999| 970 + 971 +**3)PLC Settings (GX Works2 )** 972 + 973 +Create a project 974 + 975 +Set PLC IP, subnet mask and gateway; 976 + 977 +Select [Binary Code] as communication data code; 978 + 979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 980 + 981 +Set PLC port number, for example 1025 982 + 983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 984 + 985 +Save settings; 986 + 987 +Download project into PLC device; 988 + 989 +Restart PLC device; 990 + 991 +**4)Configure the communication protocol** 992 + 993 +[[image:image-20220825142659-1.png]] 994 + 995 +**5)Cable Wiring** 996 + 997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 998 + 999 +== **QJ71E71 Ethernet Protocol** == 1000 + 1001 +Mitsubishi QJ71E71 Ethernet communication module; 1002 + 1003 +**1)V-BOX Settings** 1004 + 1005 +|**Items**|**Settings**|**Note** 1006 +|Protocol|MIT QJ71E71 MELSEC| 1007 +|Connection|Ethernet| 1008 +|Port No.|1025|Must be the same as the PLC setting 1009 +|PLC station No.|0|Must be the same as the PLC setting 1010 + 1011 +**2)Address List** 1012 + 1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 1015 +|Y|Y|Y h|0~~1FFF| 1016 +|M|M|M d|0~~99999| 1017 +|L|L|L d|0~~8191| 1018 +|F|F|F d|0~~2047| 1019 +|B|B|B h|0~~1FFF| 1020 +|V|V|V d|0~~2047| 1021 +|TS|TS|TS d|0~~2047| 1022 +|TC|TC|TC d|0~~2047| 1023 +|SS|SS|SS d|0~~2047| 1024 +|SC|SC|SC d|0~~2047| 1025 +|CS|CS|CS d|0~~1023| 1026 +|CC|CC|CC d|0~~1023| 1027 +|SB|SB|SB h|0~~7FF| 1028 +|S|S|S d|0~~8191| 1029 +|DX|DX|DX h|0~~1FFF| 1030 +|DY|DY|DY h|0~~1FFF| 1031 +|SM|SM|SM d|8000~~9999| 1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 1033 +|D|D|D d|0~~12287| 1034 +|W|W|W h|0~~1FFF| 1035 +|TN|TN|TN d|0~~2047| 1036 +|SN|SN|SN d|0~~2047| 1037 +|CN|CN|CN d|0~~1023| 1038 +|R|R|R d|0~~32767| 1039 +|SW|SW|SW h|0~~7FF| 1040 +|Z|Z|Z d|0~~15| 1041 +|ZR|ZR|ZR h|0~~FE7FF| 1042 + 1043 +**3)PLC Settings(GX Works2)** 1044 + 1045 +* Click [Ethernet/CC IE/MELSECNET]; 1046 +* Please select [Ethernet] as network type; 1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 1048 +* Select [Online] as Mode; 1049 +* Click [Operation setting] to set IP; 1050 +* Select [Binary Code] as [Communication Data Code]; 1051 +* Set protocol: TCP; 1052 +* Set [unpassive] in [Open system]; 1053 +* Set [receive] in [Fixed buffer]; 1054 +* Set [procedure Exist] in [Fixed buffer communication]; 1055 +* Disable [Pairing open]; 1056 +* Set [No confirm] in [Existence confirmation]; 1057 +* Host station port number: 1025; 1058 +* Save settings; 1059 +* Download project into PLC and restart it 1060 + 1061 +**4)Configure the communication protocol** 1062 + 1063 +[[image:image-20220825143728-1.png]] 1064 + 1065 +**5)Cable Wiring** 1066 + 1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1068 + 1069 += Create communication with **Delta PLC** = 1070 + 1071 +== **DVP Ethernet Protocol** == 1072 + 1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1074 + 1075 +== **DVP serial protocol** == 1076 + 1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1078 + 1079 +== **AS Ethernet Protocol** == 1080 + 1081 +**1)V-BOX Settings** 1082 + 1083 +|=**Items**|=**Settings**|=**Note** 1084 +|Protocol|DELTA AS300 MODBUS TCP| 1085 +|Connection|Ethernet| 1086 +|Port No.|502| 1087 +|Device No.|1| 1088 +|HMI No.|0| 1089 + 1090 +**2)Address List** 1091 + 1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1093 +|Bit|X|X|X d|0~~63| 1094 +|Bit|Y|Y|Y d|0~~63| 1095 +|Bit|D|D|D d|0~~29999| 1096 +|Bit|M|M|M d|0~~8191| 1097 +|Bit|SM|SM|SM d|0~~4095| 1098 +|Bit|S|S|S h|0~~2047| 1099 +|Bit|T|T|T d|0~~511| 1100 +|Bit|C|C|C d|0~~511| 1101 +|Bit|HC|HC|HC d|0~~255| 1102 +|Word|X|X|X h|0~~63| 1103 +|Word|Y|Y|Y d|0~~63| 1104 +|Word|SR|SR|SR d|0~~2047| 1105 +|Word|D|D|D d|0~~29999| 1106 +|Word|T|T|T d|0~~511| 1107 +|Word|C|C|C h|0~~511| 1108 +|Word|E|E|E d|0~~9| 1109 + 1110 +**3)Configure the communication protocol** 1111 + 1112 + 1113 +[[image:image-20220831160010-4.png]] 1114 + 1115 +**4)Cable Wiring** 1116 + 1117 +Figure 1118 + 1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] 1120 + 1121 +Pin Definition Diagram 1122 + 1123 +[[image:image-20220831155157-3.png]] 1124 + 1125 += Create communication with **Omron PLC** = 1126 + 1127 +== **CP1 Series Protocol ** == 1128 + 1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1130 + 1131 +== **CP2M Series Protocol** == 1132 + 1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1134 + 1135 + 1136 +== **EC55 Series Protocol** == 1137 + 1138 +Supported device: EC55 temperature instrument 1139 + 1140 +**1)V-BOX Settings** 1141 + 1142 +|**Items**|**Settings**|**Note** 1143 +|Protocol|Omron EC55| 1144 +|Connection|RS485 (9600, 2, 7, EVEN)| 1145 +|Port No.|None| 1146 +|PLC station No.|0| 1147 + 1148 +**2)Address List** 1149 + 1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function** 1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 1157 +|CP|-|0-6|Read controller intrinsic property 1158 +|CS|-|0-2|Read controller states 1159 +|CA|-|0-17|Action command 1160 + 1161 +**3)Device Settings** 1162 + 1163 +Omron E5CC PLC configuration 1164 + 1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 1166 + 1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 1168 + 1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 1170 + 1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 1172 + 1173 +**✎Note:** The communication settings for HMI should be consistent with this setting. 1174 + 1175 +**4)Configure the communication protocol** 1176 + 1177 +[[image:image-20220831161041-1.png]] 1178 + 1179 +**5)Cable Wiring** 1180 + 1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1182 + 1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1184 + 1185 +**✎Note:** 1186 + 1187 +* COM3 only available in PI8000/PI9000 series. 1188 +* CA address could not support continuous writing function; 1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid 1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. 1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. 1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 + 1197 += Create communication with Xinje** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=34]] = 1198 + 1199 +== **XC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=35]] == 1200 + 1201 +**1)HMI Settings** 1202 + 1203 +|**Item**|**Settings**|**Note** 1204 +|Protocol|XINJE XC MODBUS| 1205 +|Connection|RS232| 1206 +|Baud rate|19200| 1207 +|Data bit|8| 1208 +|Parity|EVEN| 1209 +|Stop bit|1| 1210 +|PLC station No.|1| 1211 + 1212 +**2)Address List** 1213 + 1214 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1215 +|Bit|M|M|M d|0~~8511| 1216 +|Bit|X|X|X o|0~~1747| 1217 +|Bit|Y|Y|Y o|0~~1747| 1218 +|Bit|S|S|S d|0~~1023| 1219 +|Bit|T|T|T d|0~~4095| 1220 +|Bit|C|C|C d|0~~634| 1221 +|Word|D|D|D d|0~~8511| 1222 +|Word|TD|TD|TD d|0~~618| 1223 +|Word|CD|CD|CD d|0~~634| 1224 +|Word|FD|FD|FD d|0~~8511| 1225 + 1226 +**3)Configure the communication protocol** 1227 + 1228 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154105-1.png?rev=1.1||alt="image-20220830154105-1.png"]] 1229 + 1230 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154159-3.png?rev=1.1||alt="image-20220830154159-3.png"]] 1231 + 1232 +**4)Cable Wiring** 1233 + 1234 +Figure 1235 + 1236 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830155728-4.png?rev=1.1||alt="image-20220830155728-4.png"]] 1237 + 1238 +Pin Definition Diagram 1239 + 1240 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154131-2.png?rev=1.1||alt="image-20220830154131-2.png"]] 1241 + 1242 +== **XD serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=36]] == 1243 + 1244 +**1)HMI Settings** 1245 + 1246 +Supported Series: Delta Xinjie XD/XE Series PLC 1247 + 1248 +|**Item**|**Settings**|**Note** 1249 +|Protocol|XINJE XD/XC MODBUS| 1250 +|Connection|RS232| 1251 +|Baud rate|19200| 1252 +|Data bit|8| 1253 +|Parity|EVEN| 1254 +|Stop bit|1| 1255 +|PLC station No.|1| 1256 + 1257 +**2)Address List** 1258 + 1259 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1260 +|Bit|M|M|M d|0~~74999| 1261 +|Bit|X1xx|X1xx|X1xx o|0~~1177| 1262 +|Bit|X2xx|X2xx|X2xx o|0~~277| 1263 +|Bit|X|X|X o|0~~77| 1264 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177| 1265 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277| 1266 +|Bit|Y|Y|Y o|0~~4095| 1267 +|Bit|SM|SM|SM d|0~~4999|((( 1268 + 1269 +))) 1270 +|Bit|T|T|T d|0~~4999| 1271 +|Bit|C|C|C d|0~~4999| 1272 +|Bit|ET|ET|ET d|0~~31| 1273 +|Bit|SE|SE|SE d|0~~31| 1274 +|Bit|HM|HM|HM d|0~~11999| 1275 +|Bit|HSC|HSC|HSC d|0~~39| 1276 +|Bit|HS|HS|HS d|0~~999| 1277 +|Bit|HT|HT|HT d|0~~1999| 1278 +|Bit|HC|HC|HC d|0~~1999| 1279 +|Bit|S|S|S d|0~~7999| 1280 +|Word|D|D|D d|0~~69999| 1281 +|Word|ID|ID|ID d|0~~99| 1282 +|Word|ID1xx|ID1xx|ID1xx d|0~~999| 1283 +|Word|ID2xx|ID2xx|ID2xx d|0~~299| 1284 +|Word|QD|QD|QD d|0~~99| 1285 +|Word|QD1xx|QD1xx|QD1xx d|0~~999| 1286 +|Word|QD2xx|QD2xx|QD2xx d|0~~299| 1287 +|Word|SD|SD|SD d|0~~4999| 1288 +|Word|TD|TD|TD d|0~~575| 1289 +|Word|CD|CD|CD d|0~~575| 1290 +|Word|ETD|ETD|ETD d|0~~31| 1291 +|Word|HD|HD|HD d|0~~24999| 1292 +|Word|HSD|HSD|HSD d|0~~1023| 1293 +|Word|HTD|HTD|HTD d|0~~95| 1294 +|Word|HCD|HCD|HCD d|0~~95| 1295 +|Word|HSCD|HSCD|HSCD d|0~~31| 1296 +|Word|FD|FD|FD d|0~~8191| 1297 +|Word|SFD|SFD|SFD d|0~~5999| 1298 +|Word|FS|FS|FS d|0~~47| 1299 + 1300 +**3)Configure the communication protocol** 1301 + 1302 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160042-1.png?rev=1.1||alt="image-20220830160042-1.png"]] 1303 + 1304 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160129-2.png?rev=1.1||alt="image-20220830160129-2.png"]] 1305 + 1306 +**4)Cable Wiring** 1307 + 1308 +Figure 1309 + 1310 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160257-4.png?rev=1.1||alt="image-20220830160257-4.png"]] 1311 + 1312 +Pin Definition Diagram 1313 + 1314 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1315 + 1316 += Create communication with Inovance** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=37]] = 1317 + 1318 +== **H3U serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=38]] == 1319 + 1320 +**1)HMI Settings** 1321 + 1322 +|**Item**|**Settings**|**Note** 1323 +|Protocol|INOVANCE H3U PLC| 1324 +|Connection|RS22| 1325 +|Baud rate|9600| 1326 +|Data bit|7| 1327 +|Parity|EVEN| 1328 +|Stop bit|1| 1329 +|PLC station No.|0| 1330 + 1331 +**2)Address List** 1332 + 1333 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1334 +|Bit|X|X|X o|0~~303237| 1335 +|Bit|Y|Y|Y o|0~~303237| 1336 +|Bit|M|M|M d|0~~99999| 1337 +|Bit|T|T|T d|0~~99999| 1338 +|Bit|C|C|C d|0~~99999| 1339 +|Bit|SM|SM|SM d|8000~~999| 1340 +|Bit|S|T|S d|0~~99999| 1341 +|Bit|Lamp|Lamp|Lamp d|0~~0| 1342 +|Word|X|X|X o|0~~303237| 1343 +|Word|Y|Y|Y o|0~~303237| 1344 +|Word|M|M|M d|0~~99999| 1345 +|Word|T|T|T d|0~~99999| 1346 +|Word|C|C|C d|0~~199| 1347 +|Word|D|D|D d|0~~7999| 1348 +|Word|S|S|S d|0~~99999| 1349 +|Word|SD|SD|SD d|8000~~9999| 1350 +|Word|R|R|R d|0~~32767| 1351 + 1352 +**3)Configure the communication protocol** 1353 + 1354 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170114-4.png?rev=1.1||alt="image-20220830170114-4.png"]] 1355 + 1356 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170017-3.png?rev=1.1||alt="image-20220830170017-3.png"]] 1357 + 1358 +**4)Cable Wiring** 1359 + 1360 +Figure 1361 + 1362 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165930-1.png?rev=1.1||alt="image-20220830165930-1.png"]] 1363 + 1364 +Pin Definition Diagram 1365 + 1366 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165947-2.png?rev=1.1||alt="image-20220830165947-2.png"]] 1367 + 1368 += Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] = 1369 + 1370 +== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] == 1371 + 1372 +**1)HMI Settings** 1373 + 1374 +|**Item**|**Settings**|**Note** 1375 +|Protocol|Panasonic FP MFWTOCOL| 1376 +|Connection|RS232| 1377 +|Baud rate|9600| 1378 +|Data bit|8| 1379 +|Parity|ODD| 1380 +|Stop bit|1| 1381 +|PLC station No.|1| 1382 + 1383 +**2)Address List** 1384 + 1385 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1386 +|Bit|X|X|X d|0~~9999| 1387 +|Bit|Y|Y|Y d|0~~9999| 1388 +|Bit|R|R|R d|0~~9999| 1389 +|Bit|T|T|T d|0~~9999| 1390 +|Bit|C|C|C d|0~~9999| 1391 +|Bit|L|L|L d|0~~9999| 1392 +|Word|WX|WX|WX d|0~~9999| 1393 +|Word|WY|WY|WY d|0~~9999| 1394 +|Word|WR|WR|WR d|0~~9999| 1395 +|Word|WL|WL|WL d|0~~9999| 1396 +|Word|LD|LD|LD d|0~~9999| 1397 +|Word|DT|DT|DT d|0~~65535| 1398 +|Word|FL|FL|FL d|0~~9999| 1399 +|Word|EV|EV|EV d|0~~9999| 1400 +|Word|SV|SV|SV d|0~~9999| 1401 + 1402 +**3)Configure the communication protocol** 1403 + 1404 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]] 1405 + 1406 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]] 1407 + 1408 +**4)Cable Wiring** 1409 + 1410 +Figure 1411 + 1412 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]] 1413 + 1414 +Pin Definition Diagram 1415 + 1416 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]] 1417 + 1418 += Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] = 1419 + 1420 +== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] == 1421 + 1422 +**1)HMI Settings** 1423 + 1424 +|**Item**|**Settings**|**Note** 1425 +|Protocol|LS XBC CNet| 1426 +|Connection|RS232| 1427 +|Baud rate|115200| 1428 +|Data bit|8| 1429 +|Parity|NONE| 1430 +|Stop bit|1| 1431 +|PLC station No.|1| 1432 + 1433 +**2)Address List** 1434 + 1435 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1436 +|Bit|P|P|P d|0~~2047| 1437 +|Bit|M|M|M d|0~~2047| 1438 +|Bit|L|L|L d|0~~11263| 1439 +|Bit|K|K|K d|0~~16183| 1440 +|Bit|F|F|F d|0~~2047| 1441 +|Bit|D|D|D d|0~~32767| 1442 +|Bit|R|R|R d|0~~32767| 1443 +|Bit|U|U|U d|0~~4095| 1444 +|Word|P|P|P d|0~~2047| 1445 +|Word|M|M|M d|0~~2047| 1446 +|Word|L|L|L d|0~~11263| 1447 +|Word|K|K|K d|0~~16183| 1448 +|Word|F|F|F d|0~~2047| 1449 +|Word|C|C|C d|0~~2047| 1450 +|Word|T|T|T d|0~~2047| 1451 +|Word|D|D|D d|0~~32767| 1452 +|Word|N|N|N d|0~~21503| 1453 +|Word|R|R|R d|0~~32767| 1454 +|Word|U|U|U d|0~~4095| 1455 +|Word|Z|Z|Z d|0~~127| 1456 +|Word|S|S|S d|0~~127| 1457 + 1458 +**3)Configure the communication protocol** 1459 + 1460 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]] 1461 + 1462 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]] 1463 + 1464 +**4)Cable Wiring** 1465 + 1466 +Figure 1467 + 1468 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]] 1469 + 1470 +Pin Definition Diagram 1471 + 1472 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]] 1473 + 1474 +== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] == 1475 + 1476 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1477 + 1478 +**HMI Settings** 1479 + 1480 +|**Items**|**Settings**|**Note** 1481 +|Protocol|LG XGK FEnet(Ethernet)| 1482 +|Connection|Ethernet| 1483 +|Port No.|2004| 1484 + 1485 +**Address List** 1486 + 1487 +|**Type**|**Register**|**Range**|**Format**|**Note** 1488 +|(% rowspan="14" %)Word|P|0~~2047|P d| 1489 +|M|0~~2047|M d| 1490 +|K|0~~2047|K d| 1491 +|F|0~~2047|F d| 1492 +|T|0~~2047|T d| 1493 +|C|0~~2047|C d| 1494 +|Z|0~~127|Z d| 1495 +|S|0~~127|S d| 1496 +|L|0~~11263|L d| 1497 +|N|0~~21503|N d| 1498 +|D|0~~32767|D d| 1499 +|R|0~~32767|R d| 1500 +|ZR|0~~65535|ZR d| 1501 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1502 + 1503 +**✎Note:** 1504 + 1505 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 1506 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 1507 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 1508 + 1509 +**Communication settings in HMI** 1510 + 601 601 Enable HMI Ethernet in [Project Settings]; 602 602 603 -(% style="text-align:center" %) 604 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 1513 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 605 605 606 606 Set PLC IP in [Device IP] settings; 607 607 608 -(% style="text-align:center" %) 609 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 1517 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]] 610 610 1519 +**Cable Wiring** 1520 + 1521 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1522 + 1523 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] = 1524 + 1525 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] == 1526 + 1527 +Supported series: SHIMADEN FP23 series 1528 + 1529 +**HMI Setting** 1530 + 1531 +|**Items**|**Settings**|**Note** 1532 +|Protocol|SHIMADEN FP23 series| 1533 +|Connection|RS485 (9600, 1, 7, EVEN)| 1534 +|Port No.|None| 1535 +|PLC station No.|0| 1536 + 1537 +**Address List** 1538 + 1539 +|**Device address**|**HMI register**|**Address range**|**Type** 1540 +|0040-0043(HEX)|FP040|100064-200067|Read only 1541 +|0100-010B(HEX)|FP100|100256-200267|Read only 1542 +|0110-0142(HEX)|FP110|100272-200322|Read only 1543 +|0182-0252(HEX)|FP182|100386-200594|Write only 1544 +|0280-0281(HEX)|FP280|100640-200641|Read only 1545 +|0300-030B(HEX)|FP300|100768-200779|Read and write 1546 +|0380-039F(HEX)|FP380|100896-200927|Read and write 1547 +|0400-04D7(HEX)|FP400|101024-201239|Read and write 1548 +|0500-05B0(HEX)|FP500|101280-201456|Read and write 1549 +|0600-0670(HEX)|FP600|101536-201814|Read and write 1550 +|0720-0738(HEX)|FP720|101824-201848|Read and write 1551 +|0800-083F(HEX)|FP800|102048-202111|Read and write 1552 +|0900-0952(HEX)|FP900|102304-202386|Read and write 1553 +| |Ctrl|0-2| 1554 + 611 611 **✎Note:** 612 612 613 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 614 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 1557 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1558 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23; 1559 +* The Ctrl register is used to store the control group number and BCC check mode. 615 615 1561 +**Ctrl Register Description** 1562 + 1563 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1564 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 1565 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1566 +* Ctrl3 reserved 1567 + 1568 +**✎Note:** 1569 + 1570 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 1571 + 616 616 **Cable Wiring** 617 617 618 - {{idOLE_LINK8"/}}1574 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 619 619 1576 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 620 620 621 - =**MitsubishiPLC**=1578 +**✎Note:** COM3 only available in PI8000/PI9000 series. 622 622 623 -== ** MitsubishiFXSeriesProtocol**==1580 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] == 624 624 625 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]1582 +Supported series: SHIMADEN SR90 series 626 626 627 - =**Delta PLC**=1584 +**HMI Setting** 628 628 629 -== **DVP Ethernet Protocol** == 1586 +|**Items**|**Settings**|**Note** 1587 +|Protocol|SHIMADEN SR90 protocol| 1588 +|Connection|RS485 (1200, 1, 7, EVEN)| 1589 +|Port No.|None| 1590 +|PLC station No.|0| 630 630 631 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1592 +**Address List** 632 632 633 -== **DVP Serial Protocol** == 1594 +|**Device address**|**HMI register**|**Address range**|**Type** 1595 +|0040-0043 (HEX)|SR040|100064-100067|Read only 1596 +|0100-010A(HEX)|SR0100|100256-100266|Read only 1597 +|0182-018C(HEX)|SR0182|100386-100396|Write only 1598 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read 1599 +|0500-050B(HEX)|SR0500|101280-101291|Write/read 1600 +|0590-0611(HEX)|SR0590|101424-101553|Write/read 1601 +|0701-0709(HEX)|SR0701|101793-101801|Write/read 1602 +| |Ctrl|0-2|~-~- 634 634 635 - [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1604 +**✎Note:** 636 636 637 -= **Omron PLC** = 1606 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1607 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90; 1608 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below; 638 638 639 - ==**CP1SeriesProtocol**==1610 +**Ctrl Register Description** 640 640 641 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1612 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1613 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 1614 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1615 +* Ctrl3 reserved 642 642 643 - ==**CJ2M Series Protocol**==1617 +**✎Note:** 644 644 645 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1619 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 646 646 647 - =**ModbusRTU**=1621 +**Cable Wiring** 648 648 649 - == **V-BOXas**==1623 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 650 650 651 - Selecthe“(%ss="mark"%)Modbus RTU Slave(AllFuction)”,1625 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 652 652 653 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,DataBit,Parity1627 +**✎Note:** COM3 only available in PI8000/PI9000 series. 654 654 1629 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] == 1630 + 1631 +Supported series: SHIMADEN MR13 series 1632 + 1633 +**HMI Setting** 1634 + 1635 +|**Items**|**Settings**|**Note** 1636 +|Protocol|SHIMADEN standard protocol| 1637 +|Connection|RS485 (1200, 1, 7, EVEN)| 1638 +|Port No.|None| 1639 +|PLC station No.|0| 1640 + 1641 +**Address List** 1642 + 1643 +|**Device address**|**HMI register**|**Address range**|**Type** 1644 +|0100-010B(HEX)|MR100|100256-300267|Read only 1645 +|0111-0126(HEX)|MR111|100273-300294|Read only 1646 +|0184-0192(HEX)|MR184|100388-300402|Write only 1647 +|0280-0282(HEX)|MR280|100640-300642|Read only 1648 +|0300-030B(HEX)|MR300|100768-300779|Read/write 1649 +|0314-0317(HEX)|MR314|100788-300791|Read/write 1650 +|031A(HEX)|MR31A|100794-300794|Read/write 1651 +|0320-0321(HEX)|MR320|100800-300801|Read/write 1652 +|0400-0504(HEX)|MR400|101024-301284|Read/write 1653 +|0506(HEX)|MR506|101286-301286|Read/write 1654 +|0510-0514(HEX)|MR510|101296-301300|Read/write 1655 +|0516-0524(HEX)|MR516|101302-301316|Read/write 1656 +|0526(HEX)|MR526|101318-301318|Read/write 1657 +|0580-08C3(HEX)|MR580|101408-302243|Read/write 1658 +|~-~-|Ctrl|0-2|~-~- 1659 + 1660 +**✎Note:** 1661 + 1662 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1663 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13; 1664 +* The Ctrl register is used to store the control group number and BCC check mode. 1665 + 1666 +**Ctrl Register Description** 1667 + 1668 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1669 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR . 1670 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1671 +* Ctrl3 reserved 1672 + 1673 +**✎Note:** 1674 + 1675 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 1676 + 1677 +**Cable Wiring** 1678 + 1679 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1680 + 1681 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1682 + 1683 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1684 + 1685 += Create communication with **Modbus RTU** = 1686 + 1687 +== **V-BOX as Slave** == 1688 + 1689 +Select the protocol "Modbus RTU Slave (All Fuction)", 1690 + 1691 +Then set baud rate, port, stop bits, data bits, parity. 1692 + 655 655 (% style="text-align:center" %) 656 656 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 657 657 658 -== **V-BOX as slave** ==1696 +== **V-BOX as Master** == 659 659 660 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,1698 +Select the protocol "Modbus RTU Master", 661 661 662 - (% class="mark" %)then setBaudRate,Port,StopBit,DataBit,Parity1700 +Then set baud rate, port, stop bits, data bits, parity 663 663 664 664 (% style="text-align:center" %) 665 665 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 666 666 667 -** AddressList**1705 +**address list** 668 668 669 669 (% class="table-bordered" %) 670 -|** Type**|**Register**|**Function code&Description**671 -|(% rowspan="11" %) Word|(% rowspan="3" %)3|04 (readinputregister:read current binary value in one or more input registers)1708 +|**type**|**register**|**Function code and description** 1709 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 672 672 |06 (write single register: write a binary value to a holding register) 673 673 |10 (write values to multiple addresses ) 674 674 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content
- image-20220825100807-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100814-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100845-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +403.6 KB - Content
- image-20220825102641-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102649-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102844-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.8 KB - Content
- image-20220825103350-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.9 KB - Content
- image-20220825103421-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.0 KB - Content
- image-20220825104904-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.5 KB - Content
- image-20220825105105-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +78.5 KB - Content
- image-20220825105533-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.8 KB - Content
- image-20220825112403-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +128.1 KB - Content
- image-20220825142437-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.5 KB - Content
- image-20220825142659-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.2 KB - Content
- image-20220825143728-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.7 KB - Content
- image-20220825160227-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +148.8 KB - Content
- image-20220825160341-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.7 KB - Content
- image-20220825160648-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.7 KB - Content
- image-20220825160820-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220825160925-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825160929-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825161440-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.7 KB - Content
- image-20220825161612-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.3 KB - Content
- image-20220831155101-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.6 KB - Content
- image-20220831155129-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.9 KB - Content
- image-20220831155157-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.8 KB - Content
- image-20220831160010-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content
- image-20220831160055-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- image-20220831161041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.1 KB - Content
- image-20220831161356-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.0 KB - Content