... ... @@ -435,7 +435,7 @@
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
438 -**1)PLC Setting**
438 +**HMI Setting**
439 439  
440 440  |**Items**|**Settings**|**Note**
441 441  |Protocol|Simens S7-300 Ethernet|
... ... @@ -443,7 +443,7 @@
443 443  |Port No.|102|
444 444  |PLC station No.|2|Need to be same as the PLC setting
445 445  
446 -**2)Address List**
446 +**Address List**
447 447  
448 448  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
449 449  |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
... ... @@ -479,145 +479,38 @@
479 479  |DBxDBW|DBxDBW nndddd|0~~99999999
480 480  |DBxDBD|DBxDBD nndddd|0~~99999999
481 481  
482 -**3)Configure the communication protocol**
483 -
484 -[[image:image-20220824161345-1.png]]
485 -
486 -**Cable Wiring**
487 -
488 -[[image:image-20220824161450-2.png]]
489 -)))
490 -)))
491 -
492 -== **S7-1200 Ethernet Protocol** ==
493 -
494 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
495 -
496 -== ** S7-XXX Ethernet** ==
497 -
498 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 -
500 -**HMI Setting**
501 -
502 -|=**Items**|=**Settings**|=**Note**
503 -|Protocol|Siemens S7-XXX|
504 -|Connection|Ethernet|
505 -|Port No.|102|
506 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 -|HMI No.|Rack (Default as 0)|
508 -
509 -Slot from TIA Portal is equal to Device No. of PIStudio
510 -
511 -Rack from TIA Portal is equal to HMI No. of PIStudio
512 -
513 -(% style="text-align:center" %)
514 -[[image:S7-XXXCommunication Settings.png]]
515 -
516 -(% style="text-align:center" %)
517 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
518 -
519 -**Address List**
520 -
521 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
522 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
523 -d:0~-~-9999
524 -
525 -o:0-7
526 -)))|
527 -|Q|Q|Q d.o|(((
528 -d:0~-~-9999
529 -
530 -o:0-7
531 -)))|
532 -|M|M|M d.o|(((
533 -d:0~-~-9999
534 -
535 -o:0-7
536 -)))|
537 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
538 -nn:0-9999,
539 -
540 -dddd:0-9999,
541 -
542 -o:0-7
543 -)))|(((
544 -nn:DB No.
545 -
546 -dddd:address value
547 -
548 -o: digit address
549 -)))
550 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
551 -|M|MW|MW d|d:0-99999|(((
552 -MW0=MB(0~~1)
553 -
554 -MW2=MB(2~~3)
555 -
556 -Address value is a multiple of 2
557 -)))
558 -|M|MD|MD d|d:0-99999|(((
559 -MD0=MB(0~~3)
560 -
561 -MD4=MB(4~~7)
562 -
563 -Address value is a multiple of 4
564 -)))
565 -|I|IW|IW d|d:0-99999|
566 -|Q|QW|QW d|d:0-99999|
567 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
568 -nn:0-9999
569 -
570 -dddd:0-9999
571 -)))|(((
572 -nn:DB No.
573 -
574 -dddd:address value
575 -)))
576 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
577 -nn:0-9999
578 -
579 -dddd:0-9999
580 -)))|(((
581 -nn:DB No.
582 -
583 -dddd:address value
584 -
585 -Address value is a multiple of 2
586 -)))
587 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
588 -nn:0-9999
589 -
590 -dddd:0-9999
591 -)))|(((
592 -nn:DB No.
593 -
594 -dddd:address value
595 -
596 -Address value is a multiple of 4
597 -)))
598 -
599 599  **Communication Settings**
600 600  
601 601  Enable HMI Ethernet in [Project Settings];
602 602  
603 603  (% style="text-align:center" %)
604 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
487 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
605 605  
606 606  Set PLC IP in [Device IP] settings;
607 607  
608 608  (% style="text-align:center" %)
609 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
492 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
610 610  
611 -**✎Note:**
494 +* PLC IP Address: PLC IP
495 +* PLC pot No.: 102(fixed)
496 +* Network:TCP_Client_2N(fixed)
612 612  
613 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
614 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
498 +(% style="text-align:center" %)
499 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
615 615  
501 +* Wait timeout: depend on actual network situation (more than 1500 ms)
502 +
616 616  **Cable Wiring**
617 617  
618 -{{id name="OLE_LINK8"/}}
505 +(% style="text-align:center" %)
506 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
507 +)))
508 +)))
619 619  
510 +== **S7-1200 Ethernet Protocol** ==
620 620  
512 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
513 +
621 621  = **Mitsubishi PLC** =
622 622  
623 623  == **Mitsubishi FX Series Protocol** ==
image-20220824161345-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.0 KB
Content
image-20220824161450-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -107.1 KB
Content