Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,131 +493,6 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== ** S7-XXX Ethernet** == 497 - 498 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 - 500 -**HMI Setting** 501 - 502 -|=**Items**|=**Settings**|=**Note** 503 -|Protocol|Siemens S7-XXX| 504 -|Connection|Ethernet| 505 -|Port No.|102| 506 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 -|HMI No.|Rack (Default as 0)| 508 - 509 -Slot from TIA Portal is equal to Device No. of PIStudio 510 - 511 -Rack from TIA Portal is equal to HMI No. of PIStudio 512 - 513 -(% style="text-align:center" %) 514 -[[image:S7-XXXCommunication Settings.png]] 515 - 516 -(% style="text-align:center" %) 517 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 518 - 519 -**Address List** 520 - 521 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 522 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 523 -d:0~-~-9999 524 - 525 -o:0-7 526 -)))| 527 -|Q|Q|Q d.o|((( 528 -d:0~-~-9999 529 - 530 -o:0-7 531 -)))| 532 -|M|M|M d.o|((( 533 -d:0~-~-9999 534 - 535 -o:0-7 536 -)))| 537 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 538 -nn:0-9999, 539 - 540 -dddd:0-9999, 541 - 542 -o:0-7 543 -)))|((( 544 -nn:DB No. 545 - 546 -dddd:address value 547 - 548 -o: digit address 549 -))) 550 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 551 -|M|MW|MW d|d:0-99999|((( 552 -MW0=MB(0~~1) 553 - 554 -MW2=MB(2~~3) 555 - 556 -Address value is a multiple of 2 557 -))) 558 -|M|MD|MD d|d:0-99999|((( 559 -MD0=MB(0~~3) 560 - 561 -MD4=MB(4~~7) 562 - 563 -Address value is a multiple of 4 564 -))) 565 -|I|IW|IW d|d:0-99999| 566 -|Q|QW|QW d|d:0-99999| 567 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 568 -nn:0-9999 569 - 570 -dddd:0-9999 571 -)))|((( 572 -nn:DB No. 573 - 574 -dddd:address value 575 -))) 576 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 577 -nn:0-9999 578 - 579 -dddd:0-9999 580 -)))|((( 581 -nn:DB No. 582 - 583 -dddd:address value 584 - 585 -Address value is a multiple of 2 586 -))) 587 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 588 -nn:0-9999 589 - 590 -dddd:0-9999 591 -)))|((( 592 -nn:DB No. 593 - 594 -dddd:address value 595 - 596 -Address value is a multiple of 4 597 -))) 598 - 599 -**Communication Settings** 600 - 601 -Enable HMI Ethernet in [Project Settings]; 602 - 603 -(% style="text-align:center" %) 604 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 605 - 606 -Set PLC IP in [Device IP] settings; 607 - 608 -(% style="text-align:center" %) 609 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 610 - 611 -**✎Note:** 612 - 613 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 614 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 615 - 616 -**Cable Wiring** 617 - 618 -{{id name="OLE_LINK8"/}} 619 - 620 - 621 621 = **Mitsubishi PLC** = 622 622 623 623 == **Mitsubishi FX Series Protocol** ==