Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]381 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 434 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -**Cable Wiring** 486 +**4)Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -493,11 +493,11 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== ** 496 +== **S7-XXX Ethernet Protocol** == 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 500 -** HMISetting**500 +**1)PLC Setting** 501 501 502 502 |=**Items**|=**Settings**|=**Note** 503 503 |Protocol|Siemens S7-XXX| ... ... @@ -506,14 +506,16 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of PIStudio509 +Slot from TIA Portal is equal to Device No. of V-net 510 510 511 -Rack from TIA Portal is equal to HMI No. of PIStudio511 +Rack from TIA Portal is equal to HMI No. of V-net 512 512 513 513 [[image:image-20220824162459-3.png]] 514 514 515 - **Address List**515 +[[image:image-20220824163305-2.png]] 516 516 517 +**2)Address List** 518 + 517 517 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 518 518 |(% rowspan="4" %)Bit|I|I|M d.o|((( 519 519 d:0~-~-9999 ... ... @@ -592,33 +592,109 @@ 592 592 Address value is a multiple of 4 593 593 ))) 594 594 595 -**Communication Settings**597 +**3)Configure the communication protocol** 596 596 597 - EnableHMI Ethernetin [Project Settings];599 +[[image:image-20220824163448-3.png]] 598 598 601 +**✎Note:** 602 + 603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 + 606 +**4)Cable Wiring** 607 + 608 +[[image:image-20220824162342-2.png]] 609 + 610 + 611 += **Mitsubishi PLC** = 612 + 613 +== **FX2N Serial Protocol** == 614 + 615 + 616 + 617 +== **FX3U Serial Protocol** == 618 + 619 + 620 +== **FX5U Serial Protocol** == 621 + 622 + 623 +== **FX5U Ethernet Protocol** == 624 + 625 +Mitsubishi FX5U series PLC 626 + 627 +**HMI Settings** 628 + 629 +|**Items**|**Settings**|**Note** 630 +|Protocol|Mitsubishi FX5U| 631 +|Connection|Ethernet| 632 +|Port No.|5002|Must be the same as the PLC setting 633 +|PLC station No.|0| 634 + 635 +**Address List** 636 + 637 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 638 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|B|B|B h|0~~7FFF| 642 +|F|F|F d|0~~32767| 643 +|SB|SB|SB h|0~~7FFF| 644 +|TS|TS|TS d|0~~1023| 645 +|TC|TC|TC d|0~~1023| 646 +|STS|STS|STS d|0~~1023| 647 +|STC|STC|STS d|0~~1023| 648 +|CS|CS|CS d|0~~1023| 649 +|CC|CC|CC d|0~~1023| 650 +|SM|SM|SM d|0~~9999| 651 +|L|L|L d|0~~32767| 652 +|S|S|S d|0~~4095| 653 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 654 +|TN|TN|TN d|0~~1023| 655 +|STN|STN|STN d|0~~1023| 656 +|CN|CN|CN d|0~~1023| 657 +|R|R|R d|0~~32767| 658 +|SW|SW|SW h|0~~7FFF| 659 +|Z|Z|Z d|0~~23| 660 +|D|D|D d|0~~7999| 661 +|SD|SD|SD d|0~~11999| 662 + 663 +**PLC Settings (GX Works 3)** 664 + 665 +Find the [Ethernet port] in the navigation area. 666 + 599 599 (% style="text-align:center" %) 600 -[[image:12.PLC Protocol_html_ 43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]668 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 601 601 602 -Set PLCIPin[DeviceIP] settings;670 +Select [Own Node Settings] in the [Setting Item List]; 603 603 672 +Set [IP Address], [Subnet Mask], [Default Gateway]; 673 + 674 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 675 + 604 604 (% style="text-align:center" %) 605 -[[image:12.PLC Protocol_html_ f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]677 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 606 606 607 - **✎Note:**679 +Select [SLMP Connection Module] and add into host station as below picture shows; 608 608 609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 610 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 681 +Set Port number as 5002 (this is necessary settings); 611 611 612 - **CableWiring**683 +Click [Close with Reflecting the Setting] to save and close window; 613 613 614 -[[image:image-20220824162342-2.png]] 685 +(% style="text-align:center" %) 686 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 615 615 616 - = **Mitsubishi PLC** =688 +Click [Apply] to completed Etherenet settings; 617 617 618 - == **MitsubishiFXSeriesProtocol**==690 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 619 619 620 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 692 +(% style="text-align:center" %) 693 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 621 621 695 +**Cable Wiring** 696 + 697 +(% style="text-align:center" %) 698 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 699 + 622 622 = **Delta PLC** = 623 623 624 624 == **DVP Ethernet Protocol** ==
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content