Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -435,7 +435,7 @@ 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 438 -** 1)PLCSetting**438 +**HMI Setting** 439 439 440 440 |**Items**|**Settings**|**Note** 441 441 |Protocol|Simens S7-300 Ethernet| ... ... @@ -443,7 +443,7 @@ 443 443 |Port No.|102| 444 444 |PLC station No.|2|Need to be same as the PLC setting 445 445 446 -** 2)Address List**446 +**Address List** 447 447 448 448 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 449 449 |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| ... ... @@ -479,140 +479,38 @@ 479 479 |DBxDBW|DBxDBW nndddd|0~~99999999 480 480 |DBxDBD|DBxDBD nndddd|0~~99999999 481 481 482 -**3)Configure the communication protocol** 483 - 484 -[[image:image-20220824161345-1.png]] 485 - 486 -**Cable Wiring** 487 - 488 -[[image:image-20220824161450-2.png]] 489 -))) 490 -))) 491 - 492 -== **S7-1200 Ethernet Protocol** == 493 - 494 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 - 496 -== ** S7-XXX Ethernet** == 497 - 498 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 - 500 -**HMI Setting** 501 - 502 -|=**Items**|=**Settings**|=**Note** 503 -|Protocol|Siemens S7-XXX| 504 -|Connection|Ethernet| 505 -|Port No.|102| 506 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 -|HMI No.|Rack (Default as 0)| 508 - 509 -Slot from TIA Portal is equal to Device No. of PIStudio 510 - 511 -Rack from TIA Portal is equal to HMI No. of PIStudio 512 - 513 -[[image:image-20220824162459-3.png]] 514 - 515 -**Address List** 516 - 517 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 518 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 519 -d:0~-~-9999 520 - 521 -o:0-7 522 -)))| 523 -|Q|Q|Q d.o|((( 524 -d:0~-~-9999 525 - 526 -o:0-7 527 -)))| 528 -|M|M|M d.o|((( 529 -d:0~-~-9999 530 - 531 -o:0-7 532 -)))| 533 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 534 -nn:0-9999, 535 - 536 -dddd:0-9999, 537 - 538 -o:0-7 539 -)))|((( 540 -nn:DB No. 541 - 542 -dddd:address value 543 - 544 -o: digit address 545 -))) 546 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 547 -|M|MW|MW d|d:0-99999|((( 548 -MW0=MB(0~~1) 549 - 550 -MW2=MB(2~~3) 551 - 552 -Address value is a multiple of 2 553 -))) 554 -|M|MD|MD d|d:0-99999|((( 555 -MD0=MB(0~~3) 556 - 557 -MD4=MB(4~~7) 558 - 559 -Address value is a multiple of 4 560 -))) 561 -|I|IW|IW d|d:0-99999| 562 -|Q|QW|QW d|d:0-99999| 563 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 564 -nn:0-9999 565 - 566 -dddd:0-9999 567 -)))|((( 568 -nn:DB No. 569 - 570 -dddd:address value 571 -))) 572 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 573 -nn:0-9999 574 - 575 -dddd:0-9999 576 -)))|((( 577 -nn:DB No. 578 - 579 -dddd:address value 580 - 581 -Address value is a multiple of 2 582 -))) 583 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 584 -nn:0-9999 585 - 586 -dddd:0-9999 587 -)))|((( 588 -nn:DB No. 589 - 590 -dddd:address value 591 - 592 -Address value is a multiple of 4 593 -))) 594 - 595 595 **Communication Settings** 596 596 597 597 Enable HMI Ethernet in [Project Settings]; 598 598 599 599 (% style="text-align:center" %) 600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img- rounded img-thumbnail"]]487 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 601 601 602 602 Set PLC IP in [Device IP] settings; 603 603 604 604 (% style="text-align:center" %) 605 -[[image:12.PLC Protocol_html_ f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]492 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 606 606 607 -**✎Note:** 494 +* PLC IP Address: PLC IP 495 +* PLC pot No.: 102(fixed) 496 +* Network:TCP_Client_2N(fixed) 608 608 609 - *The S7-1200supports simultaneous connection of three devices, sothe driver supports simultaneous accessto PLC by three touch screens.610 - * HMIaccessPLC,use S7 protocol,access PLC TSAP 02.01(s7-1200 PROFINET interfaceonlysupports three connections,thedefaultsupport),detailedreferenceto thesystemmanualof S7-1200.498 +(% style="text-align:center" %) 499 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 611 611 501 +* Wait timeout: depend on actual network situation (more than 1500 ms) 502 + 612 612 **Cable Wiring** 613 613 614 -[[image:image-20220824162342-2.png]] 505 +(% style="text-align:center" %) 506 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 507 +))) 508 +))) 615 615 510 +== **S7-1200 Ethernet Protocol** == 511 + 512 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 513 + 616 616 = **Mitsubishi PLC** = 617 617 618 618 == **Mitsubishi FX Series Protocol** ==
- image-20220824161345-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.0 KB - Content
- image-20220824161450-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content