Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 92.1
edited by Ben
on 2022/08/24 16:25
Change comment: There is no comment for this version
To version 94.1
edited by Ben
on 2022/08/24 16:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -493,7 +493,7 @@
493 493  
494 494  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
495 495  
496 -== ** S7-XXX Ethernet** ==
496 +== **S7-XXX Ethernet Protocol** ==
497 497  
498 498  Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
... ... @@ -506,12 +506,14 @@
506 506  |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 507  |HMI No.|Rack (Default as 0)|
508 508  
509 -Slot from TIA Portal is equal to Device No. of PIStudio
509 +Slot from TIA Portal is equal to Device No. of V-net
510 510  
511 -Rack from TIA Portal is equal to HMI No. of PIStudio
511 +Rack from TIA Portal is equal to HMI No. of V-net
512 512  
513 513  [[image:image-20220824162459-3.png]]
514 514  
515 +[[image:image-20220824163305-2.png]]
516 +
515 515  **Address List**
516 516  
517 517  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
... ... @@ -594,20 +594,12 @@
594 594  
595 595  **Communication Settings**
596 596  
597 -Enable HMI Ethernet in [Project Settings];
599 +[[image:image-20220824163448-3.png]]
598 598  
599 -(% style="text-align:center" %)
600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
601 -
602 -Set PLC IP in [Device IP] settings;
603 -
604 -(% style="text-align:center" %)
605 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
606 -
607 607  **✎Note:**
608 608  
609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
610 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
611 611  
612 612  **Cable Wiring**
613 613  
image-20220824163110-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content