Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,7 +493,7 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== ** 496 +== **S7-XXX Ethernet Protocol** == 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 ... ... @@ -506,12 +506,14 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of PIStudio509 +Slot from TIA Portal is equal to Device No. of V-net 510 510 511 -Rack from TIA Portal is equal to HMI No. of PIStudio511 +Rack from TIA Portal is equal to HMI No. of V-net 512 512 513 513 [[image:image-20220824162459-3.png]] 514 514 515 +[[image:image-20220824163305-2.png]] 516 + 515 515 **Address List** 516 516 517 517 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** ... ... @@ -594,20 +594,12 @@ 594 594 595 595 **Communication Settings** 596 596 597 - EnableHMI Ethernetin [Project Settings];599 +[[image:image-20220824163448-3.png]] 598 598 599 -(% style="text-align:center" %) 600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 601 - 602 -Set PLC IP in [Device IP] settings; 603 - 604 -(% style="text-align:center" %) 605 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 606 - 607 607 **✎Note:** 608 608 609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.610 -* HMIaccess PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 611 611 612 612 **Cable Wiring** 613 613
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content