Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 93.1
edited by Ben
on 2022/08/24 16:26
Change comment: There is no comment for this version
To version 105.1
edited by Ben
on 2022/08/25 10:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -378,7 +378,7 @@
378 378  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
379 379  )))
380 380  
381 -[[image:image-20220714162814-10.png]]
381 +[[image:image-20220824164346-1.png]]
382 382  
383 383  
384 384  (((
... ... @@ -431,7 +431,7 @@
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 432  
433 433  
434 -== ** S7-300 Ethernet Protocol** ==
434 +== **S7-300 Ethernet Protocol** ==
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
... ... @@ -483,7 +483,7 @@
483 483  
484 484  [[image:image-20220824161345-1.png]]
485 485  
486 -**Cable Wiring**
486 +**4)Cable Wiring**
487 487  
488 488  [[image:image-20220824161450-2.png]]
489 489  )))
... ... @@ -497,7 +497,7 @@
497 497  
498 498  Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
500 -**HMI Setting**
500 +**1)PLC Setting**
501 501  
502 502  |=**Items**|=**Settings**|=**Note**
503 503  |Protocol|Siemens S7-XXX|
... ... @@ -506,14 +506,16 @@
506 506  |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 507  |HMI No.|Rack (Default as 0)|
508 508  
509 -Slot from TIA Portal is equal to Device No. of PIStudio
509 +Slot from TIA Portal is equal to Device No. of V-net
510 510  
511 -Rack from TIA Portal is equal to HMI No. of PIStudio
511 +Rack from TIA Portal is equal to HMI No. of V-net
512 512  
513 513  [[image:image-20220824162459-3.png]]
514 514  
515 -**Address List**
515 +[[image:image-20220824163305-2.png]]
516 516  
517 +**2)Address List**
518 +
517 517  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
518 518  |(% rowspan="4" %)Bit|I|I|M d.o|(((
519 519  d:0~-~-9999
... ... @@ -592,33 +592,149 @@
592 592  Address value is a multiple of 4
593 593  )))
594 594  
595 -**Communication Settings**
597 +**3)Configure the communication protocol**
596 596  
597 -Enable HMI Ethernet in [Project Settings];
599 +[[image:image-20220824163448-3.png]]
598 598  
601 +**✎Note:**
602 +
603 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
604 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
605 +
606 +**4)Cable Wiring**
607 +
608 +[[image:image-20220824162342-2.png]]
609 +
610 +
611 += **Mitsubishi PLC** =
612 +
613 +== **FX1S,1N,2N Serial Protocol** ==
614 +
615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
616 +
617 +**1)V-BOX Settings**
618 +
619 +|**Item**|**Settings**|**Note**
620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
621 +|Connection|RS422/RS485/RS232|
622 +|Baud rate|9600~~115200|
623 +|Data bit|7/8|
624 +|Parity|EVEN/Odd/None|
625 +|Stop bit|1/2|
626 +|PLC station No.|1~~255|
627 +
628 +**2)Address List**
629 +
630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
632 +|Y|Y|Y o|0~~303237|
633 +|M|M|M d|0~~99999|
634 +|T|T|T d|0~~99999|
635 +|C|C|C d|0~~99999|
636 +|S|S|S d|0~~99999|
637 +|SM|SM|SM d|8000~~9999|
638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
639 +|Y|Y|Y o|0~~303237|
640 +|M|M|M d|0~~99999|
641 +|T|T|T d|0~~99999|
642 +|C|C|C d|0~~199|
643 +|D|D|D d|0~~7999|
644 +|S|S|S d|0~~99999|
645 +|SD|SD|SD d|8000~~9999|
646 +
647 +**3)Cable Wiring**
648 +
649 +* **RS422**
650 +
651 +[[image:image-20220825100814-3.png]]
652 +
653 +[[image:image-20220825100845-4.png]]
654 +
655 +
656 +
657 +== **FX3U Serial Protocol** ==
658 +
659 +
660 +== **FX5U Serial Protocol** ==
661 +
662 +
663 +== **FX5U Ethernet Protocol** ==
664 +
665 +Mitsubishi FX5U series PLC
666 +
667 +**HMI Settings**
668 +
669 +|**Items**|**Settings**|**Note**
670 +|Protocol|Mitsubishi FX5U|
671 +|Connection|Ethernet|
672 +|Port No.|5002|Must be the same as the PLC setting
673 +|PLC station No.|0|
674 +
675 +**Address List**
676 +
677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
678 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
679 +|Y|Y|Y o|0~~303237|
680 +|M|M|M d|0~~99999|
681 +|B|B|B h|0~~7FFF|
682 +|F|F|F d|0~~32767|
683 +|SB|SB|SB h|0~~7FFF|
684 +|TS|TS|TS d|0~~1023|
685 +|TC|TC|TC d|0~~1023|
686 +|STS|STS|STS d|0~~1023|
687 +|STC|STC|STS d|0~~1023|
688 +|CS|CS|CS d|0~~1023|
689 +|CC|CC|CC d|0~~1023|
690 +|SM|SM|SM d|0~~9999|
691 +|L|L|L d|0~~32767|
692 +|S|S|S d|0~~4095|
693 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
694 +|TN|TN|TN d|0~~1023|
695 +|STN|STN|STN d|0~~1023|
696 +|CN|CN|CN d|0~~1023|
697 +|R|R|R d|0~~32767|
698 +|SW|SW|SW h|0~~7FFF|
699 +|Z|Z|Z d|0~~23|
700 +|D|D|D d|0~~7999|
701 +|SD|SD|SD d|0~~11999|
702 +
703 +**PLC Settings (GX Works 3)**
704 +
705 +Find the [Ethernet port] in the navigation area.
706 +
599 599  (% style="text-align:center" %)
600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
708 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
601 601  
602 -Set PLC IP in [Device IP] settings;
710 +Select [Own Node Settings] in the [Setting Item List];
603 603  
712 +Set [IP Address], [Subnet Mask], [Default Gateway];
713 +
714 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
715 +
604 604  (% style="text-align:center" %)
605 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
717 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
606 606  
607 -**✎Note:**
719 +Select [SLMP Connection Module] and add into host station as below picture shows;
608 608  
609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
610 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
721 +Set Port number as 5002 (this is necessary settings);
611 611  
612 -**Cable Wiring**
723 +Click [Close with Reflecting the Setting] to save and close window;
613 613  
614 -[[image:image-20220824162342-2.png]]
725 +(% style="text-align:center" %)
726 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
615 615  
616 -= **Mitsubishi PLC** =
728 +Click [Apply] to completed Etherenet settings;
617 617  
618 -== **Mitsubishi FX Series Protocol** ==
730 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
619 619  
620 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
732 +(% style="text-align:center" %)
733 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
621 621  
735 +**Cable Wiring**
736 +
737 +(% style="text-align:center" %)
738 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
739 +
622 622  = **Delta PLC** =
623 623  
624 624  == **DVP Ethernet Protocol** ==
image-20220824163110-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content
image-20220824164346-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.2 KB
Content
image-20220825100807-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100814-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +943.0 KB
Content
image-20220825100845-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content