Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 33 added, 0 removed)
- image-20220824163110-1.png
- image-20220824163305-2.png
- image-20220824163448-3.png
- image-20220824164346-1.png
- image-20220825100807-1.png
- image-20220825100814-3.png
- image-20220825100845-4.png
- image-20220825102641-1.png
- image-20220825102649-2.png
- image-20220825102844-3.png
- image-20220825103350-4.png
- image-20220825103421-5.png
- image-20220825104904-1.png
- image-20220825105105-2.png
- image-20220825105533-3.png
- image-20220825112403-1.png
- image-20220825142437-1.png
- image-20220825142659-1.png
- image-20220825143728-1.png
- image-20220825160227-1.png
- image-20220825160341-2.png
- image-20220825160648-3.png
- image-20220825160820-4.png
- image-20220825160925-5.png
- image-20220825160929-6.png
- image-20220825161440-7.png
- image-20220825161612-8.png
- image-20220831155101-1.png
- image-20220831155129-2.png
- image-20220831155157-3.png
- image-20220831160010-4.png
- image-20220831160055-5.png
- image-20220831161041-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,10 @@ 1 -= (% style="color:inherit; font-family:inherit"%)**WECON PLC**(%%)=1 += Create communication with WECON PLC = 2 2 3 -== **LX3V 3 +== **LX3V Serial Protocol** == 4 4 5 -Supported series: W ECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) PLCSettings**7 +**1)V-BOX setting** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,8 +15,9 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**2) PLCAddress List**18 +**2)Address List** 19 19 20 + 20 20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 21 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 22 22 |Y|Y|Y o|0~~303237| ... ... @@ -35,9 +35,9 @@ 35 35 36 36 **3)Configure the communication protocol** 37 37 38 -[[image:image-20220824152217-1.png]] 39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] 39 39 40 -**4) hardwareconnection**41 +**4)Cable Wiring** 41 41 42 42 * **RS422** 43 43 ... ... @@ -175,7 +175,7 @@ 175 175 176 176 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 177 177 178 -= **Rockwell PLC** = 179 += Create communication with **Rockwell PLC** = 179 179 180 180 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 181 181 ... ... @@ -216,7 +216,7 @@ 216 216 217 217 [[image:image-20220824110724-1.png]] 218 218 219 -== ** CompactLogixProtocol** ==220 +== **Micro850_FreeTag Protocol** == 220 220 221 221 ((( 222 222 ((( ... ... @@ -355,7 +355,7 @@ 355 355 356 356 ((( 357 357 ((( 358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 359 359 ))) 360 360 361 361 ... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]382 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -424,7 +424,7 @@ 424 424 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 425 425 426 426 427 -= **Siemens PLC** = 428 += Create communication with **Siemens PLC** = 428 428 429 429 == **S7-200 Smart Ethernet Protocol** == 430 430 ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 435 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -**Cable Wiring** 487 +**4)Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -497,7 +497,7 @@ 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 500 -** HMISetting**501 +**1)PLC Setting** 501 501 502 502 |=**Items**|=**Settings**|=**Note** 503 503 |Protocol|Siemens S7-XXX| ... ... @@ -506,14 +506,16 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of PIStudio510 +Slot from TIA Portal is equal to Device No. of V-net 510 510 511 -Rack from TIA Portal is equal to HMI No. of PIStudio512 +Rack from TIA Portal is equal to HMI No. of V-net 512 512 513 513 [[image:image-20220824162459-3.png]] 514 514 515 - **Address List**516 +[[image:image-20220824163305-2.png]] 516 516 518 +**2)Address List** 519 + 517 517 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 518 518 |(% rowspan="4" %)Bit|I|I|M d.o|((( 519 519 d:0~-~-9999 ... ... @@ -592,78 +592,630 @@ 592 592 Address value is a multiple of 4 593 593 ))) 594 594 595 -**Communication Settings**598 +**3)Configure the communication protocol** 596 596 597 - EnableHMI Ethernetin [Project Settings];600 +[[image:image-20220824163448-3.png]] 598 598 599 -(% style="text-align:center" %) 600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 602 +**✎Note:** 601 601 602 -Set PLC IP in [Device IP] settings; 604 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 605 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 603 603 604 -(% style="text-align:center" %) 605 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 607 +**4)Cable Wiring** 606 606 607 - **✎Note:**609 +[[image:image-20220824162342-2.png]] 608 608 609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 610 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 611 += Create communication with **Mitsubishi PLC** = 611 611 612 -** CableWiring**613 +== **FX1S,1N,2N Serial Protocol** == 613 613 614 - [[image:image-20220824162342-2.png]]615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 615 615 616 - =**Mitsubishi PLC**=617 +**1)V-BOX Settings** 617 617 618 -== **Mitsubishi FX Series Protocol** == 619 +|**Item**|**Settings**|**Note** 620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 621 +|Connection|RS422/RS485/RS232| 622 +|Baud rate|9600~~115200| 623 +|Data bit|7/8| 624 +|Parity|EVEN/Odd/None| 625 +|Stop bit|1/2| 626 +|PLC station No.|1~~255| 619 619 620 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]628 +**2)Address List** 621 621 622 -= **Delta PLC** = 630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 632 +|Y|Y|Y o|0~~303237| 633 +|M|M|M d|0~~99999| 634 +|T|T|T d|0~~99999| 635 +|C|C|C d|0~~99999| 636 +|S|S|S d|0~~99999| 637 +|SM|SM|SM d|8000~~9999| 638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|T|T|T d|0~~99999| 642 +|C|C|C d|0~~199| 643 +|D|D|D d|0~~7999| 644 +|S|S|S d|0~~99999| 645 +|SD|SD|SD d|8000~~9999| 623 623 647 +**3)Configure the communication protocol** 648 + 649 +[[image:image-20220825102844-3.png]] 650 + 651 +**4)Cable Wiring** 652 + 653 +* **RS422** 654 + 655 +[[image:image-20220825103350-4.png]] 656 + 657 +[[image:image-20220825100845-4.png]] 658 + 659 + 660 +== **FX3U,3G,3GA Serial Protocol** == 661 + 662 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 663 + 664 +**1)V-BOX Settings** 665 + 666 +|**Item**|**Settings**|**Note** 667 +|Protocol|Mitsubishi FX3U/3G/3GA| 668 +|Connection|RS422/RS485/RS232| 669 +|Baud rate|9600~~115200| 670 +|Data bit|7/8| 671 +|Parity|EVEN/Odd/None| 672 +|Stop bit|1/2| 673 +|PLC station No.|1~~255| 674 + 675 +**2)Address List** 676 + 677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 678 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 679 +|Y|Y|Y o|0~~303237| 680 +|M|M|M d|0~~99999| 681 +|T|T|T d|0~~99999| 682 +|C|C|C d|0~~99999| 683 +|S|S|S d|0~~99999| 684 +|SM|SM|SM d|8000~~9999| 685 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 686 +|Y|Y|Y o|0~~303237| 687 +|M|M|M d|0~~99999| 688 +|T|T|T d|0~~99999| 689 +|C|C|C d|0~~199| 690 +|D|D|D d|0~~7999| 691 +|S|S|S d|0~~99999| 692 +|SD|SD|SD d|8000~~9999| 693 + 694 +**3)Configure the communication protocol** 695 + 696 +[[image:image-20220825102649-2.png]] 697 + 698 +**4)Cable Wiring** 699 + 700 +* **RS422** 701 + 702 +[[image:image-20220825103421-5.png]] 703 + 704 +[[image:image-20220825100845-4.png]] 705 + 706 + 707 +== **FX5U Serial Protocol** == 708 + 709 +Mitsubishi FX5U series PLC 710 + 711 +**1)V-BOX Settings** 712 + 713 +|**Item**|**Settings**|**Note** 714 +|Protocol|Mitsubishi FX5U| 715 +|Connection|RS422/RS485| 716 +|Baud rate|9600| 717 +|Data bit|7| 718 +|Parity|Odd| 719 +|Stop bit|1| 720 +|PLC station No.|1~~255|Need to be the same as PLC settings 721 + 722 +**2)Address List** 723 + 724 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 725 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 726 +|Y|Y|Y o|0~~303237| 727 +|M|M|M d|0~~99999| 728 +|B|B|B h|0~~7FFF| 729 +|F|F|F d|0~~32767| 730 +|SB|SB|SB h|0~~7FFF| 731 +|TS|TS|TS d|0~~1023| 732 +|TC|TC|TC d|0~~1023| 733 +|STS|STS|STS d|0~~1023| 734 +|STC|STC|STS d|0~~1023| 735 +|CS|CS|CS d|0~~1023| 736 +|CC|CC|CC d|0~~1023| 737 +|SM|SM|SM d|0~~9999| 738 +|L|L|L d|0~~32767| 739 +|S|S|S d|0~~4095| 740 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 741 +|TN|TN|TN d|0~~1023| 742 +|STN|STN|STN d|0~~1023| 743 +|CN|CN|CN d|0~~1023| 744 +|R|R|R d|0~~32767| 745 +|SW|SW|SW h|0~~7FFF| 746 +|Z|Z|Z d|0~~23| 747 +|D|D|D d|0~~7999| 748 +|SD|SD|SD d|0~~11999| 749 + 750 +**3)PLC Settings (GX Works 3)** 751 + 752 +Create a blank FX5U project 753 + 754 +Find the 485 serial port module in the system navigation bar and double click to enter the settings. 755 + 756 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 757 + 758 +Select protocol in the setting item, and set parameters. 759 + 760 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 761 + 762 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 763 + 764 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 765 + 766 +Click the [Apply] button to finish the setting. 767 + 768 +Click download and select the items as below, then click [execute] to download the configuration to PLC. 769 + 770 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 771 + 772 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 773 + 774 +Done. 775 + 776 +**4)Configure the communication protocol** 777 + 778 +[[image:image-20220825104904-1.png]] 779 + 780 +**5)Cable Wiring** 781 + 782 + 783 +* **RS422** 784 + 785 +[[image:image-20220825105105-2.png]] 786 + 787 +[[image:image-20220825105533-3.png]] 788 + 789 +== **FX5U Ethernet Protocol** == 790 + 791 +Mitsubishi FX5U series PLC 792 + 793 +**1)V-BOX Settings** 794 + 795 +|**Items**|**Settings**|**Note** 796 +|Protocol|Mitsubishi FX5U| 797 +|Connection|Ethernet| 798 +|Port No.|5002|Must be the same as the PLC setting 799 +|PLC station No.|0| 800 + 801 +**2)Address List** 802 + 803 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 804 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 805 +|Y|Y|Y o|0~~303237| 806 +|M|M|M d|0~~99999| 807 +|B|B|B h|0~~7FFF| 808 +|F|F|F d|0~~32767| 809 +|SB|SB|SB h|0~~7FFF| 810 +|TS|TS|TS d|0~~1023| 811 +|TC|TC|TC d|0~~1023| 812 +|STS|STS|STS d|0~~1023| 813 +|STC|STC|STS d|0~~1023| 814 +|CS|CS|CS d|0~~1023| 815 +|CC|CC|CC d|0~~1023| 816 +|SM|SM|SM d|0~~9999| 817 +|L|L|L d|0~~32767| 818 +|S|S|S d|0~~4095| 819 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 820 +|TN|TN|TN d|0~~1023| 821 +|STN|STN|STN d|0~~1023| 822 +|CN|CN|CN d|0~~1023| 823 +|R|R|R d|0~~32767| 824 +|SW|SW|SW h|0~~7FFF| 825 +|Z|Z|Z d|0~~23| 826 +|D|D|D d|0~~7999| 827 +|SD|SD|SD d|0~~11999| 828 + 829 +**3)PLC Settings (GX Works 3)** 830 + 831 +Find the [Ethernet port] in the navigation area. 832 + 833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 834 + 835 +Select [Own Node Settings] in the [Setting Item List]; 836 + 837 +Set [IP Address], [Subnet Mask], [Default Gateway]; 838 + 839 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 840 + 841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 842 + 843 +Select [SLMP Connection Module] and add into host station as below picture shows; 844 + 845 +Set Port number as 5002 (this is necessary settings); 846 + 847 +Click [Close with Reflecting the Setting] to save and close window; 848 + 849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 850 + 851 +Click [Apply] to completed Etherenet settings; 852 + 853 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 854 + 855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 856 + 857 +**4)Configure the communication protocol** 858 + 859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 + 861 +**5)电缆布线** 862 + 863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 + 865 + 866 +== **L02 Serial Protocol** == 867 + 868 +Mitsubishi L02 series CPU built-in serial port. 869 + 870 +**1)V-BOX Settings** 871 + 872 +|**Item**|**Settings**|**Note** 873 +|Protocol|Mitsubishi L02| 874 +|Connection|RS422| 875 +|Baud rate|115200| 876 +|Data bit|8| 877 +|Parity|Odd| 878 +|Stop bit|1| 879 +|PLC station No.|1~~255|Need to be the same as PLC settings 880 + 881 +**2)Address List** 882 + 883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 884 +|Bit|X|X|X h|0~~FFFF| 885 +|Bit|Y|Y|Y h|0~~FFFF| 886 +|Bit|M|M|M d|0~~9999| 887 +|Bit|L|L|L d|0~~9999| 888 +|Bit|F|F|F d|0~~9999| 889 +|Bit|B|B|B h|0~~FFFF| 890 +|Bit|V|V|V d|0~~2047| 891 +|Bit|TC|TC|TC d|0~~9999| 892 +|Bit|SS|SS|SS d|0~~9999| 893 +|Bit|SC|SC|SC d|0~~9999| 894 +|Bit|CS|CS|CS d|0~~9999| 895 +|Bit|CC|CC|CC d|0~~9999| 896 +|Bit|SB|SB|SB h|0~~FFFF| 897 +|Bit|SM|SM|SM d|0~~2047| 898 +|Bit|STS|STS|STS d|0~~1023| 899 +|Bit|S|S|S d|0~~9999| 900 +|Bit|DX|DX|DX h|0~~FFFF| 901 +|Bit|DY|DY|DY h|0~~FFFF| 902 +|Bit|TS|TS|TS d|0~~9999| 903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 904 +|Word|W|W|W h|0~~FFFF| 905 +|Word|TN|TN|TN d|0~~99999| 906 +|Word|SN|SN|SN d|0~~99999| 907 +|Word|CN|CN|CN d|0~~99999| 908 +|Word|R|R|R d|0~~99999| 909 +|Word|SW|SW|SW h|0~~FFFF| 910 +|Word|Z|Z|Z d|0~~99999| 911 +|Word|ZR|ZR|ZR h|0~~FFFF| 912 +|Word|D|D|D d|0~~99999| 913 + 914 +**3)Communication Settings** 915 + 916 +[[image:image-20220825160648-3.png]] 917 + 918 +**4)Cable Wiring** 919 + 920 +* **RS422** 921 + 922 +[[image:image-20220825161612-8.png]] 923 + 924 +[[image:image-20220825160820-4.png]] 925 + 926 +== **L02 Ethernet Protocol** == 927 + 928 +Mitsubishi L series CPU built-in Ethernet port. 929 + 930 +**1)V-BOX Settings** 931 + 932 +|**Items**|**Settings**|**Note** 933 +|Protocol|MIT L02 CPU MELSEC| 934 +|Connection|Ethernet| 935 +|Port No.|1025|Must be the same as the PLC setting 936 +|PLC station No.|0|Must be the same as the PLC setting 937 + 938 +**2)Address List** 939 + 940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 941 +|Bit|X|X|X h|0~~FFFF| 942 +|Bit|Y|Y|Y h|0~~FFFF| 943 +|Bit|M|M|M d|0~~9999| 944 +|Bit|L|L|L d|0~~9999| 945 +|Bit|F|F|F d|0~~9999| 946 +|Bit|B|B|B h|0~~FFFF| 947 +|Bit|V|V|V d|0~~2047| 948 +|Bit|TC|TC|TC d|0~~9999| 949 +|Bit|SS|SS|SS d|0~~9999| 950 +|Bit|SC|SC|SC d|0~~9999| 951 +|Bit|CS|CS|CS d|0~~9999| 952 +|Bit|CC|CC|CC d|0~~9999| 953 +|Bit|SB|SB|SB h|0~~FFFF| 954 +|Bit|SM|SM|SM d|0~~2047| 955 +|Bit|STS|STS|STS d|0~~1023| 956 +|Bit|S|S|S d|0~~9999| 957 +|Bit|DX|DX|DX h|0~~FFFF| 958 +|Bit|DY|DY|DY h|0~~FFFF| 959 +|Bit|TS|TS|TS d|0~~9999| 960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 961 +|Word|W|W|W h|0~~FFFF| 962 +|Word|TN|TN|TN d|0~~99999| 963 +|Word|SN|SN|SN d|0~~99999| 964 +|Word|CN|CN|CN d|0~~99999| 965 +|Word|R|R|R d|0~~99999| 966 +|Word|SW|SW|SW h|0~~FFFF| 967 +|Word|Z|Z|Z d|0~~99999| 968 +|Word|ZR|ZR|ZR h|0~~FFFF| 969 +|Word|D|D|D d|0~~99999| 970 + 971 +**3)PLC Settings (GX Works2 )** 972 + 973 +Create a project 974 + 975 +Set PLC IP, subnet mask and gateway; 976 + 977 +Select [Binary Code] as communication data code; 978 + 979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 980 + 981 +Set PLC port number, for example 1025 982 + 983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 984 + 985 +Save settings; 986 + 987 +Download project into PLC device; 988 + 989 +Restart PLC device; 990 + 991 +**4)Configure the communication protocol** 992 + 993 +[[image:image-20220825142659-1.png]] 994 + 995 +**5)Cable Wiring** 996 + 997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 998 + 999 +== **QJ71E71 Ethernet Protocol** == 1000 + 1001 +Mitsubishi QJ71E71 Ethernet communication module; 1002 + 1003 +**1)V-BOX Settings** 1004 + 1005 +|**Items**|**Settings**|**Note** 1006 +|Protocol|MIT QJ71E71 MELSEC| 1007 +|Connection|Ethernet| 1008 +|Port No.|1025|Must be the same as the PLC setting 1009 +|PLC station No.|0|Must be the same as the PLC setting 1010 + 1011 +**2)Address List** 1012 + 1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 1015 +|Y|Y|Y h|0~~1FFF| 1016 +|M|M|M d|0~~99999| 1017 +|L|L|L d|0~~8191| 1018 +|F|F|F d|0~~2047| 1019 +|B|B|B h|0~~1FFF| 1020 +|V|V|V d|0~~2047| 1021 +|TS|TS|TS d|0~~2047| 1022 +|TC|TC|TC d|0~~2047| 1023 +|SS|SS|SS d|0~~2047| 1024 +|SC|SC|SC d|0~~2047| 1025 +|CS|CS|CS d|0~~1023| 1026 +|CC|CC|CC d|0~~1023| 1027 +|SB|SB|SB h|0~~7FF| 1028 +|S|S|S d|0~~8191| 1029 +|DX|DX|DX h|0~~1FFF| 1030 +|DY|DY|DY h|0~~1FFF| 1031 +|SM|SM|SM d|8000~~9999| 1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 1033 +|D|D|D d|0~~12287| 1034 +|W|W|W h|0~~1FFF| 1035 +|TN|TN|TN d|0~~2047| 1036 +|SN|SN|SN d|0~~2047| 1037 +|CN|CN|CN d|0~~1023| 1038 +|R|R|R d|0~~32767| 1039 +|SW|SW|SW h|0~~7FF| 1040 +|Z|Z|Z d|0~~15| 1041 +|ZR|ZR|ZR h|0~~FE7FF| 1042 + 1043 +**3)PLC Settings(GX Works2)** 1044 + 1045 +* Click [Ethernet/CC IE/MELSECNET]; 1046 +* Please select [Ethernet] as network type; 1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 1048 +* Select [Online] as Mode; 1049 +* Click [Operation setting] to set IP; 1050 +* Select [Binary Code] as [Communication Data Code]; 1051 +* Set protocol: TCP; 1052 +* Set [unpassive] in [Open system]; 1053 +* Set [receive] in [Fixed buffer]; 1054 +* Set [procedure Exist] in [Fixed buffer communication]; 1055 +* Disable [Pairing open]; 1056 +* Set [No confirm] in [Existence confirmation]; 1057 +* Host station port number: 1025; 1058 +* Save settings; 1059 +* Download project into PLC and restart it 1060 + 1061 +**4)Configure the communication protocol** 1062 + 1063 +[[image:image-20220825143728-1.png]] 1064 + 1065 +**5)Cable Wiring** 1066 + 1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1068 + 1069 += Create communication with **Delta PLC** = 1070 + 624 624 == **DVP Ethernet Protocol** == 625 625 626 -[[ download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 627 627 628 -== **DVP SerialProtocol** ==1075 +== **DVP serial protocol** == 629 629 630 -[[ download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 631 631 632 -= ** Omron PLC** =1079 +== **AS Ethernet Protocol** == 633 633 634 - ==**CP1 SeriesProtocol**==1081 +**1)V-BOX Settings** 635 635 636 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1083 +|=**Items**|=**Settings**|=**Note** 1084 +|Protocol|DELTA AS300 MODBUS TCP| 1085 +|Connection|Ethernet| 1086 +|Port No.|502| 1087 +|Device No.|1| 1088 +|HMI No.|0| 637 637 638 - ==**CJ2M SeriesProtocol**==1090 +**2)Address List** 639 639 640 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1093 +|Bit|X|X|X d|0~~63| 1094 +|Bit|Y|Y|Y d|0~~63| 1095 +|Bit|D|D|D d|0~~29999| 1096 +|Bit|M|M|M d|0~~8191| 1097 +|Bit|SM|SM|SM d|0~~4095| 1098 +|Bit|S|S|S h|0~~2047| 1099 +|Bit|T|T|T d|0~~511| 1100 +|Bit|C|C|C d|0~~511| 1101 +|Bit|HC|HC|HC d|0~~255| 1102 +|Word|X|X|X h|0~~63| 1103 +|Word|Y|Y|Y d|0~~63| 1104 +|Word|SR|SR|SR d|0~~2047| 1105 +|Word|D|D|D d|0~~29999| 1106 +|Word|T|T|T d|0~~511| 1107 +|Word|C|C|C h|0~~511| 1108 +|Word|E|E|E d|0~~9| 641 641 642 - =**ModbusRTU**=1110 +**3)Configure the communication protocol** 643 643 644 -== **V-BOX as master** == 645 645 646 - Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,1113 +[[image:image-20220831160010-4.png]] 647 647 648 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,Data Bit,Parity1115 +**4)Cable Wiring** 649 649 1117 +Figure 1118 + 1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] 1120 + 1121 +Pin Definition Diagram 1122 + 1123 +[[image:image-20220831155157-3.png]] 1124 + 1125 += Create communication with **Omron PLC** = 1126 + 1127 +== **CP1 Series Protocol ** == 1128 + 1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1130 + 1131 +== **CP2M Series Protocol** == 1132 + 1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1134 + 1135 + 1136 +== **EC55 Protocol** == 1137 + 1138 +Supported device: EC55 temperature instrument 1139 + 1140 +**1)V-BOX Settings** 1141 + 1142 +|**Items**|**Settings**|**Note** 1143 +|Protocol|Omron EC55| 1144 +|Connection|RS485 (9600, 2, 7, EVEN)| 1145 +|Port No.|None| 1146 +|PLC station No.|0| 1147 + 1148 +**2)Address List** 1149 + 1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function** 1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 1157 +|CP|-|0-6|Read controller intrinsic property 1158 +|CS|-|0-2|Read controller states 1159 +|CA|-|0-17|Action command 1160 + 1161 +**3)Device Settings** 1162 + 1163 +Omron E5CC PLC configuration 1164 + 1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 1166 + 1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 1168 + 1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 1170 + 1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 1172 + 1173 +**✎Note:** The communication settings for HMI should be consistent with this setting. 1174 + 1175 +**4)Configure the communication protocol** 1176 + 1177 +[[image:image-20220831161041-1.png]] 1178 + 1179 +**5)Cable Wiring** 1180 + 1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1182 + 1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1184 + 1185 +**✎Note:** 1186 + 1187 +* COM3 only available in PI8000/PI9000 series. 1188 +* CA address could not support continuous writing function; 1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid 1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. 1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. 1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 + 1197 += Create communication with **Modbus RTU** = 1198 + 1199 +== **V-BOX as Slave** == 1200 + 1201 +Select the protocol "Modbus RTU Slave (All Fuction)", 1202 + 1203 +Then set baud rate, port, stop bits, data bits, parity. 1204 + 650 650 (% style="text-align:center" %) 651 651 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 652 652 653 -== **V-BOX as slave** ==1208 +== **V-BOX as Master** == 654 654 655 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,1210 +Select the protocol "Modbus RTU Master", 656 656 657 - (% class="mark" %)then setBaudRate,Port,StopBit,DataBit,Parity1212 +Then set baud rate, port, stop bits, data bits, parity 658 658 659 659 (% style="text-align:center" %) 660 660 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 661 661 662 -** AddressList**1217 +**address list** 663 663 664 664 (% class="table-bordered" %) 665 -|** Type**|**Register**|**Function code&Description**666 -|(% rowspan="11" %) Word|(% rowspan="3" %)3|04 (readinputregister:read current binary value in one or more input registers)1220 +|**type**|**register**|**Function code and description** 1221 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 667 667 |06 (write single register: write a binary value to a holding register) 668 668 |10 (write values to multiple addresses ) 669 669 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content
- image-20220825100807-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100814-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100845-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +403.6 KB - Content
- image-20220825102641-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102649-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.2 KB - Content
- image-20220825102844-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.8 KB - Content
- image-20220825103350-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.9 KB - Content
- image-20220825103421-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.0 KB - Content
- image-20220825104904-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +123.5 KB - Content
- image-20220825105105-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +78.5 KB - Content
- image-20220825105533-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.8 KB - Content
- image-20220825112403-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +128.1 KB - Content
- image-20220825142437-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.5 KB - Content
- image-20220825142659-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.2 KB - Content
- image-20220825143728-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.7 KB - Content
- image-20220825160227-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +148.8 KB - Content
- image-20220825160341-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.7 KB - Content
- image-20220825160648-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.7 KB - Content
- image-20220825160820-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220825160925-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825160929-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825161440-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.7 KB - Content
- image-20220825161612-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.3 KB - Content
- image-20220831155101-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.6 KB - Content
- image-20220831155129-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.9 KB - Content
- image-20220831155157-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.8 KB - Content
- image-20220831160010-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content
- image-20220831160055-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- image-20220831161041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.1 KB - Content