Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,126 +493,6 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== **S7-XXX Ethernet Protocol** == 497 - 498 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 - 500 -**HMI Setting** 501 - 502 -|=**Items**|=**Settings**|=**Note** 503 -|Protocol|Siemens S7-XXX| 504 -|Connection|Ethernet| 505 -|Port No.|102| 506 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 -|HMI No.|Rack (Default as 0)| 508 - 509 -Slot from TIA Portal is equal to Device No. of PIStudio 510 - 511 -Rack from TIA Portal is equal to HMI No. of PIStudio 512 - 513 -[[image:image-20220824162459-3.png]] 514 - 515 -**Address List** 516 - 517 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 518 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 519 -d:0~-~-9999 520 - 521 -o:0-7 522 -)))| 523 -|Q|Q|Q d.o|((( 524 -d:0~-~-9999 525 - 526 -o:0-7 527 -)))| 528 -|M|M|M d.o|((( 529 -d:0~-~-9999 530 - 531 -o:0-7 532 -)))| 533 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 534 -nn:0-9999, 535 - 536 -dddd:0-9999, 537 - 538 -o:0-7 539 -)))|((( 540 -nn:DB No. 541 - 542 -dddd:address value 543 - 544 -o: digit address 545 -))) 546 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 547 -|M|MW|MW d|d:0-99999|((( 548 -MW0=MB(0~~1) 549 - 550 -MW2=MB(2~~3) 551 - 552 -Address value is a multiple of 2 553 -))) 554 -|M|MD|MD d|d:0-99999|((( 555 -MD0=MB(0~~3) 556 - 557 -MD4=MB(4~~7) 558 - 559 -Address value is a multiple of 4 560 -))) 561 -|I|IW|IW d|d:0-99999| 562 -|Q|QW|QW d|d:0-99999| 563 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 564 -nn:0-9999 565 - 566 -dddd:0-9999 567 -)))|((( 568 -nn:DB No. 569 - 570 -dddd:address value 571 -))) 572 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 573 -nn:0-9999 574 - 575 -dddd:0-9999 576 -)))|((( 577 -nn:DB No. 578 - 579 -dddd:address value 580 - 581 -Address value is a multiple of 2 582 -))) 583 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 584 -nn:0-9999 585 - 586 -dddd:0-9999 587 -)))|((( 588 -nn:DB No. 589 - 590 -dddd:address value 591 - 592 -Address value is a multiple of 4 593 -))) 594 - 595 -**Communication Settings** 596 - 597 -Enable HMI Ethernet in [Project Settings]; 598 - 599 -(% style="text-align:center" %) 600 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 601 - 602 -Set PLC IP in [Device IP] settings; 603 - 604 -(% style="text-align:center" %) 605 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 606 - 607 -**✎Note:** 608 - 609 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 610 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 611 - 612 -**Cable Wiring** 613 - 614 -[[image:image-20220824162342-2.png]] 615 - 616 616 = **Mitsubishi PLC** = 617 617 618 618 == **Mitsubishi FX Series Protocol** ==
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content