... ... @@ -378,7 +378,7 @@
378 378  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
379 379  )))
380 380  
381 -[[image:image-20220714162814-10.png]]
381 +[[image:image-20220824164346-1.png]]
382 382  
383 383  
384 384  (((
... ... @@ -431,7 +431,7 @@
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 432  
433 433  
434 -== ** S7-300 Ethernet Protocol** ==
434 +== **S7-300 Ethernet Protocol** ==
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
... ... @@ -483,7 +483,7 @@
483 483  
484 484  [[image:image-20220824161345-1.png]]
485 485  
486 -**Cable Wiring**
486 +**4)Cable Wiring**
487 487  
488 488  [[image:image-20220824161450-2.png]]
489 489  )))
... ... @@ -497,7 +497,7 @@
497 497  
498 498  Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
500 -**HMI Setting**
500 +**1)PLC Setting**
501 501  
502 502  |=**Items**|=**Settings**|=**Note**
503 503  |Protocol|Siemens S7-XXX|
... ... @@ -514,7 +514,7 @@
514 514  
515 515  [[image:image-20220824163305-2.png]]
516 516  
517 -**Address List**
517 +**2)Address List**
518 518  
519 519  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
520 520  |(% rowspan="4" %)Bit|I|I|M d.o|(((
... ... @@ -594,7 +594,7 @@
594 594  Address value is a multiple of 4
595 595  )))
596 596  
597 -**Communication Settings**
597 +**3)Configure the communication protocol**
598 598  
599 599  [[image:image-20220824163448-3.png]]
600 600  
... ... @@ -603,16 +603,100 @@
603 603  * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
604 604  * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
605 605  
606 -**Cable Wiring**
606 +**4)Cable Wiring**
607 607  
608 608  [[image:image-20220824162342-2.png]]
609 609  
610 +
610 610  = **Mitsubishi PLC** =
611 611  
612 -== **Mitsubishi FX Series Protocol** ==
613 +== **FX2N Serial Protocol** ==
613 613  
614 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
615 615  
616 +
617 +== **FX3U Serial Protocol** ==
618 +
619 +
620 +== **FX5U Serial Protocol** ==
621 +
622 +
623 +== **FX5U Ethernet Protocol** ==
624 +
625 +Mitsubishi FX5U series PLC
626 +
627 +**HMI Settings**
628 +
629 +|**Items**|**Settings**|**Note**
630 +|Protocol|Mitsubishi FX5U|
631 +|Connection|Ethernet|
632 +|Port No.|5002|Must be the same as the PLC setting
633 +|PLC station No.|0|
634 +
635 +**Address List**
636 +
637 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
638 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
639 +|Y|Y|Y o|0~~303237|
640 +|M|M|M d|0~~99999|
641 +|B|B|B h|0~~7FFF|
642 +|F|F|F d|0~~32767|
643 +|SB|SB|SB h|0~~7FFF|
644 +|TS|TS|TS d|0~~1023|
645 +|TC|TC|TC d|0~~1023|
646 +|STS|STS|STS d|0~~1023|
647 +|STC|STC|STS d|0~~1023|
648 +|CS|CS|CS d|0~~1023|
649 +|CC|CC|CC d|0~~1023|
650 +|SM|SM|SM d|0~~9999|
651 +|L|L|L d|0~~32767|
652 +|S|S|S d|0~~4095|
653 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
654 +|TN|TN|TN d|0~~1023|
655 +|STN|STN|STN d|0~~1023|
656 +|CN|CN|CN d|0~~1023|
657 +|R|R|R d|0~~32767|
658 +|SW|SW|SW h|0~~7FFF|
659 +|Z|Z|Z d|0~~23|
660 +|D|D|D d|0~~7999|
661 +|SD|SD|SD d|0~~11999|
662 +
663 +**PLC Settings (GX Works 3)**
664 +
665 +Find the [Ethernet port] in the navigation area.
666 +
667 +(% style="text-align:center" %)
668 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
669 +
670 +Select [Own Node Settings] in the [Setting Item List];
671 +
672 +Set [IP Address], [Subnet Mask], [Default Gateway];
673 +
674 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
675 +
676 +(% style="text-align:center" %)
677 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
678 +
679 +Select [SLMP Connection Module] and add into host station as below picture shows;
680 +
681 +Set Port number as 5002 (this is necessary settings);
682 +
683 +Click [Close with Reflecting the Setting] to save and close window;
684 +
685 +(% style="text-align:center" %)
686 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
687 +
688 +Click [Apply] to completed Etherenet settings;
689 +
690 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
691 +
692 +(% style="text-align:center" %)
693 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
694 +
695 +**Cable Wiring**
696 +
697 +(% style="text-align:center" %)
698 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
699 +
616 616  = **Delta PLC** =
617 617  
618 618  == **DVP Ethernet Protocol** ==