Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]381 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 434 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -**Cable Wiring** 486 +**4)Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -497,7 +497,7 @@ 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 500 -** HMISetting**500 +**1)PLC Setting** 501 501 502 502 |=**Items**|=**Settings**|=**Note** 503 503 |Protocol|Siemens S7-XXX| ... ... @@ -514,7 +514,7 @@ 514 514 515 515 [[image:image-20220824163305-2.png]] 516 516 517 -**Address List** 517 +**2)Address List** 518 518 519 519 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 520 520 |(% rowspan="4" %)Bit|I|I|M d.o|((( ... ... @@ -594,7 +594,7 @@ 594 594 Address value is a multiple of 4 595 595 ))) 596 596 597 -**Communication Settings**597 +**3)Configure the communication protocol** 598 598 599 599 [[image:image-20220824163448-3.png]] 600 600 ... ... @@ -603,16 +603,100 @@ 603 603 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 604 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 605 606 -**Cable Wiring** 606 +**4)Cable Wiring** 607 607 608 608 [[image:image-20220824162342-2.png]] 609 609 610 + 610 610 = **Mitsubishi PLC** = 611 611 612 -== ** MitsubishiFX SeriesProtocol** ==613 +== **FX2N Serial Protocol** == 613 613 614 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 615 615 616 + 617 +== **FX3U Serial Protocol** == 618 + 619 + 620 +== **FX5U Serial Protocol** == 621 + 622 + 623 +== **FX5U Ethernet Protocol** == 624 + 625 +Mitsubishi FX5U series PLC 626 + 627 +**HMI Settings** 628 + 629 +|**Items**|**Settings**|**Note** 630 +|Protocol|Mitsubishi FX5U| 631 +|Connection|Ethernet| 632 +|Port No.|5002|Must be the same as the PLC setting 633 +|PLC station No.|0| 634 + 635 +**Address List** 636 + 637 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 638 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|B|B|B h|0~~7FFF| 642 +|F|F|F d|0~~32767| 643 +|SB|SB|SB h|0~~7FFF| 644 +|TS|TS|TS d|0~~1023| 645 +|TC|TC|TC d|0~~1023| 646 +|STS|STS|STS d|0~~1023| 647 +|STC|STC|STS d|0~~1023| 648 +|CS|CS|CS d|0~~1023| 649 +|CC|CC|CC d|0~~1023| 650 +|SM|SM|SM d|0~~9999| 651 +|L|L|L d|0~~32767| 652 +|S|S|S d|0~~4095| 653 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 654 +|TN|TN|TN d|0~~1023| 655 +|STN|STN|STN d|0~~1023| 656 +|CN|CN|CN d|0~~1023| 657 +|R|R|R d|0~~32767| 658 +|SW|SW|SW h|0~~7FFF| 659 +|Z|Z|Z d|0~~23| 660 +|D|D|D d|0~~7999| 661 +|SD|SD|SD d|0~~11999| 662 + 663 +**PLC Settings (GX Works 3)** 664 + 665 +Find the [Ethernet port] in the navigation area. 666 + 667 +(% style="text-align:center" %) 668 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 669 + 670 +Select [Own Node Settings] in the [Setting Item List]; 671 + 672 +Set [IP Address], [Subnet Mask], [Default Gateway]; 673 + 674 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 675 + 676 +(% style="text-align:center" %) 677 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 678 + 679 +Select [SLMP Connection Module] and add into host station as below picture shows; 680 + 681 +Set Port number as 5002 (this is necessary settings); 682 + 683 +Click [Close with Reflecting the Setting] to save and close window; 684 + 685 +(% style="text-align:center" %) 686 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 687 + 688 +Click [Apply] to completed Etherenet settings; 689 + 690 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 691 + 692 +(% style="text-align:center" %) 693 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 694 + 695 +**Cable Wiring** 696 + 697 +(% style="text-align:center" %) 698 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 699 + 616 616 = **Delta PLC** = 617 617 618 618 == **DVP Ethernet Protocol** ==
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content