Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,7 +493,7 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== **S7-XXX Ethernet Protocol** ==496 +== ** S7-XXX Ethernet** == 497 497 498 498 Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 499 ... ... @@ -506,13 +506,15 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of V-net509 +Slot from TIA Portal is equal to Device No. of PIStudio 510 510 511 -Rack from TIA Portal is equal to HMI No. of V-net511 +Rack from TIA Portal is equal to HMI No. of PIStudio 512 512 513 -[[image:image-20220824162459-3.png]] 513 +(% style="text-align:center" %) 514 +[[image:S7-XXXCommunication Settings.png]] 514 514 515 -[[image:image-20220824163305-2.png]] 516 +(% style="text-align:center" %) 517 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 516 516 517 517 **Address List** 518 518 ... ... @@ -596,17 +596,26 @@ 596 596 597 597 **Communication Settings** 598 598 599 - [[image:image-20220824163448-3.png]]601 +Enable HMI Ethernet in [Project Settings]; 600 600 603 +(% style="text-align:center" %) 604 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 605 + 606 +Set PLC IP in [Device IP] settings; 607 + 608 +(% style="text-align:center" %) 609 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 610 + 601 601 **✎Note:** 602 602 603 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.604 -* V-BOXaccess PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.613 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 614 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 605 606 606 **Cable Wiring** 607 607 608 - [[image:image-20220824162342-2.png]]618 +{{id name="OLE_LINK8"/}} 609 609 620 + 610 610 = **Mitsubishi PLC** = 611 611 612 612 == **Mitsubishi FX Series Protocol** ==
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.8 KB - Content