Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -506,14 +506,12 @@ 506 506 |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 507 |HMI No.|Rack (Default as 0)| 508 508 509 -Slot from TIA Portal is equal to Device No. of V-net509 +Slot from TIA Portal is equal to Device No. of PIStudio 510 510 511 -Rack from TIA Portal is equal to HMI No. of V-net511 +Rack from TIA Portal is equal to HMI No. of PIStudio 512 512 513 513 [[image:image-20220824162459-3.png]] 514 514 515 -[[image:image-20220824163305-2.png]] 516 - 517 517 **Address List** 518 518 519 519 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** ... ... @@ -596,12 +596,20 @@ 596 596 597 597 **Communication Settings** 598 598 599 - [[image:image-20220824163448-3.png]]597 +Enable HMI Ethernet in [Project Settings]; 600 600 599 +(% style="text-align:center" %) 600 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 601 + 602 +Set PLC IP in [Device IP] settings; 603 + 604 +(% style="text-align:center" %) 605 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 606 + 601 601 **✎Note:** 602 602 603 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.604 -* V-BOXaccess PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.609 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 610 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 605 606 606 **Cable Wiring** 607 607
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.8 KB - Content