Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 714162814-10.png]]381 +[[image:image-20220824164346-1.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== ** 434 +== **S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -**Cable Wiring** 486 +**4)Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -607,12 +607,136 @@ 607 607 608 608 [[image:image-20220824162342-2.png]] 609 609 610 + 610 610 = **Mitsubishi PLC** = 611 611 612 -== ** MitsubishiFX SeriesProtocol** ==613 +== **FX1S,1N,2N Serial Protocol** == 613 613 614 - [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]615 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 615 615 617 +**1)V-BOX Settings** 618 + 619 +|**Item**|**Settings**|**Note** 620 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 621 +|Connection|RS422/RS485/RS232| 622 +|Baud rate|9600~~115200| 623 +|Data bit|7/8| 624 +|Parity|EVEN/Odd/None| 625 +|Stop bit|1/2| 626 +|PLC station No.|1~~255| 627 + 628 +**2)Address List** 629 + 630 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 631 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 632 +|Y|Y|Y o|0~~303237| 633 +|M|M|M d|0~~99999| 634 +|T|T|T d|0~~99999| 635 +|C|C|C d|0~~99999| 636 +|S|S|S d|0~~99999| 637 +|SM|SM|SM d|8000~~9999| 638 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 639 +|Y|Y|Y o|0~~303237| 640 +|M|M|M d|0~~99999| 641 +|T|T|T d|0~~99999| 642 +|C|C|C d|0~~199| 643 +|D|D|D d|0~~7999| 644 +|S|S|S d|0~~99999| 645 +|SD|SD|SD d|8000~~9999| 646 + 647 +**3)Cable Wiring** 648 + 649 +* **RS422** 650 + 651 +[[image:image-20220825100814-3.png]] 652 + 653 +[[image:image-20220825100845-4.png]] 654 + 655 + 656 + 657 +== **FX3U Serial Protocol** == 658 + 659 + 660 +== **FX5U Serial Protocol** == 661 + 662 + 663 +== **FX5U Ethernet Protocol** == 664 + 665 +Mitsubishi FX5U series PLC 666 + 667 +**HMI Settings** 668 + 669 +|**Items**|**Settings**|**Note** 670 +|Protocol|Mitsubishi FX5U| 671 +|Connection|Ethernet| 672 +|Port No.|5002|Must be the same as the PLC setting 673 +|PLC station No.|0| 674 + 675 +**Address List** 676 + 677 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 678 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 679 +|Y|Y|Y o|0~~303237| 680 +|M|M|M d|0~~99999| 681 +|B|B|B h|0~~7FFF| 682 +|F|F|F d|0~~32767| 683 +|SB|SB|SB h|0~~7FFF| 684 +|TS|TS|TS d|0~~1023| 685 +|TC|TC|TC d|0~~1023| 686 +|STS|STS|STS d|0~~1023| 687 +|STC|STC|STS d|0~~1023| 688 +|CS|CS|CS d|0~~1023| 689 +|CC|CC|CC d|0~~1023| 690 +|SM|SM|SM d|0~~9999| 691 +|L|L|L d|0~~32767| 692 +|S|S|S d|0~~4095| 693 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 694 +|TN|TN|TN d|0~~1023| 695 +|STN|STN|STN d|0~~1023| 696 +|CN|CN|CN d|0~~1023| 697 +|R|R|R d|0~~32767| 698 +|SW|SW|SW h|0~~7FFF| 699 +|Z|Z|Z d|0~~23| 700 +|D|D|D d|0~~7999| 701 +|SD|SD|SD d|0~~11999| 702 + 703 +**PLC Settings (GX Works 3)** 704 + 705 +Find the [Ethernet port] in the navigation area. 706 + 707 +(% style="text-align:center" %) 708 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 709 + 710 +Select [Own Node Settings] in the [Setting Item List]; 711 + 712 +Set [IP Address], [Subnet Mask], [Default Gateway]; 713 + 714 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 715 + 716 +(% style="text-align:center" %) 717 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 718 + 719 +Select [SLMP Connection Module] and add into host station as below picture shows; 720 + 721 +Set Port number as 5002 (this is necessary settings); 722 + 723 +Click [Close with Reflecting the Setting] to save and close window; 724 + 725 +(% style="text-align:center" %) 726 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 727 + 728 +Click [Apply] to completed Etherenet settings; 729 + 730 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 731 + 732 +(% style="text-align:center" %) 733 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 734 + 735 +**Cable Wiring** 736 + 737 +(% style="text-align:center" %) 738 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 739 + 616 616 = **Delta PLC** = 617 617 618 618 == **DVP Ethernet Protocol** ==
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content
- image-20220825100807-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100814-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +943.0 KB - Content
- image-20220825100845-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +403.6 KB - Content