Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
52.1 | 1 | = (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = |
![]() |
1.1 | 2 | |
![]() |
63.1 | 3 | == **LX3V Serial Protocol** == |
![]() |
31.1 | 4 | |
![]() |
20.1 | 5 | Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM |
![]() |
1.1 | 6 | |
![]() |
81.1 | 7 | **1)PLC Settings** |
![]() |
1.1 | 8 | |
![]() |
20.1 | 9 | |**Item**|**Settings**|**Note** |
10 | |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| | ||
11 | |Connection|RS422/RS485| | ||
12 | |Baud rate|9600| | ||
13 | |Data bit|7| | ||
14 | |Parity|EVEN| | ||
15 | |Stop bit|1| | ||
16 | |PLC station No.|1| | ||
![]() |
1.1 | 17 | |
![]() |
82.1 | 18 | **2)PLC Address List** |
![]() |
20.1 | 19 | |
20 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
21 | |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| | ||
22 | |Y|Y|Y o|0~~303237| | ||
23 | |M|M|M d|0~~99999| | ||
24 | |T|T|T d|0~~99999| | ||
25 | |C|C|C d|0~~99999| | ||
26 | |S|S|S d|0~~99999| | ||
27 | |(% rowspan="8" %)Word|X|X|Xo|0~~303237| | ||
28 | |Y|Y|Y o|0~~303237| | ||
29 | |M|M|M d|0~~99999| | ||
30 | |T|T|T d|0~~99999| | ||
31 | |C|C|C d|0~~199| | ||
32 | |D|D|D d|0~~7999| | ||
33 | |S|S|S d|0~~99999| | ||
34 | |SD|SD|SD d|8000~~9999| | ||
35 | |||
![]() |
83.1 | 36 | **3)Configure the communication protocol** |
![]() |
20.1 | 37 | |
![]() |
80.1 | 38 | [[image:image-20220824152217-1.png]] |
39 | |||
![]() |
83.1 | 40 | **4)hardware connection** |
![]() |
80.1 | 41 | |
![]() |
20.1 | 42 | * **RS422** |
43 | |||
![]() |
69.1 | 44 | [[image:image-20220824120614-5.png]] |
![]() |
20.1 | 45 | |
![]() |
68.1 | 46 | * **RS485** |
47 | |||
![]() |
69.1 | 48 | [[image:image-20220824120524-3.png]] |
![]() |
68.1 | 49 | |
![]() |
63.1 | 50 | == **LX5V Serial Protocol** == |
![]() |
28.1 | 51 | |
![]() |
84.1 | 52 | This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. |
![]() |
20.1 | 53 | |
54 | **Software configuration of PLC** | ||
55 | |||
56 | **1)PLC programming software** | ||
57 | |||
![]() |
71.1 | 58 | [[image:image-20220824142722-1.png]] |
![]() |
20.1 | 59 | |
60 | **2)New PLC project** | ||
61 | |||
62 | Click New Project and select the PLC model. | ||
63 | |||
![]() |
33.1 | 64 | [[image:image-20220822172623-2.png]] |
![]() |
20.1 | 65 | |
66 | **3)Set Serial port parameters** | ||
67 | |||
68 | Follow the steps below to configure Serial port parameters | ||
69 | |||
70 | Baud rate:115200 | ||
71 | |||
72 | Data bit:8 | ||
73 | |||
74 | Stop bit:1 | ||
75 | |||
76 | Parity:No verification | ||
77 | |||
![]() |
33.1 | 78 | [[image:image-20220822172657-3.png]] |
![]() |
20.1 | 79 | |
80 | **4)Registers list** | ||
81 | |||
![]() |
33.1 | 82 | [[image:image-20220822172730-4.png]] |
![]() |
20.1 | 83 | |
![]() |
33.1 | 84 | **V-BOX software configuration** |
![]() |
28.1 | 85 | |
![]() |
35.1 | 86 | **1)V-BOX programming software** |
![]() |
20.1 | 87 | |
![]() |
35.1 | 88 | [[image:image-20220824104124-1.png]] |
![]() |
20.1 | 89 | |
![]() |
35.1 | 90 | **2)V-NET add device** |
![]() |
20.1 | 91 | |
![]() |
35.1 | 92 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. |
![]() |
20.1 | 93 | |
![]() |
35.1 | 94 | [[image:image-20220824104909-2.png]] |
![]() |
20.1 | 95 | |
96 | **3)Set communication port parameters** | ||
97 | |||
98 | Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. | ||
99 | |||
100 | Baud rate:115200 | ||
101 | |||
102 | Data bit:8 | ||
103 | |||
104 | Stop bit:1 | ||
105 | |||
106 | Parity:No verification | ||
107 | |||
![]() |
70.1 | 108 | [[image:image-20220824142130-1.png]] |
![]() |
20.1 | 109 | |
110 | **hardware connection** | ||
111 | |||
112 | **1)Hardware wiring diagram** | ||
113 | |||
![]() |
70.1 | 114 | [[image:image-20220824142546-2.png]] |
![]() |
28.1 | 115 | |
![]() |
70.1 | 116 | [[image:image-20220824142643-3.png]] |
![]() |
28.1 | 117 | |
![]() |
74.1 | 118 | The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. |
![]() |
20.1 | 119 | |
![]() |
63.1 | 120 | == **LX5V-N Ethernet protocol** == |
![]() |
20.1 | 121 | |
![]() |
77.1 | 122 | This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. |
![]() |
20.1 | 123 | |
124 | **Software configuration of PLC** | ||
125 | |||
126 | **1)PLC programming software** | ||
127 | |||
![]() |
72.1 | 128 | [[image:image-20220824142722-1.png]] |
![]() |
20.1 | 129 | |
130 | **2)New PLC project** | ||
131 | |||
132 | Click New Project and select the PLC model. | ||
133 | |||
![]() |
73.1 | 134 | [[image:image-20220824143613-1.png]] |
![]() |
20.1 | 135 | |
136 | **3)Set Ethernet port parameters** | ||
137 | |||
138 | Follow the steps below to configure Ethernet parameters | ||
139 | |||
140 | PLC IP address:192.168.39.200 | ||
141 | |||
142 | default gateway:192.168.39.1 | ||
143 | |||
144 | subnet mask:255.255.255.0 | ||
145 | |||
![]() |
73.1 | 146 | [[image:image-20220824143744-2.png]] |
![]() |
20.1 | 147 | |
148 | **4)Registers list** | ||
149 | |||
![]() |
74.1 | 150 | [[image:image-20220822172730-4.png]] |
![]() |
20.1 | 151 | |
![]() |
74.1 | 152 | (% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** |
![]() |
20.1 | 153 | |
![]() |
74.1 | 154 | **1)V-BOX programming software** |
![]() |
20.1 | 155 | |
![]() |
74.1 | 156 | [[image:image-20220824104124-1.png]] |
![]() |
20.1 | 157 | |
![]() |
74.1 | 158 | **2)V-NET add device** |
![]() |
20.1 | 159 | |
![]() |
74.1 | 160 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. |
![]() |
20.1 | 161 | |
![]() |
74.1 | 162 | [[image:image-20220824104909-2.png]] |
![]() |
20.1 | 163 | |
![]() |
79.1 | 164 | **3)Set communication Protocol** |
![]() |
20.1 | 165 | |
![]() |
74.1 | 166 | Click Communication to configure the LX5V plc protocol and IP address. |
![]() |
20.1 | 167 | |
![]() |
74.1 | 168 | [[image:image-20220824144619-1.png]] |
![]() |
20.1 | 169 | |
170 | **hardware connection** | ||
171 | |||
172 | **1)Hardware wiring diagram** | ||
173 | |||
![]() |
74.1 | 174 | [[image:image-20220824151127-2.png]] |
![]() |
20.1 | 175 | |
![]() |
74.1 | 176 | The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. |
![]() |
20.1 | 177 | |
![]() |
23.1 | 178 | = **Rockwell PLC** = |
![]() |
22.1 | 179 | |
![]() |
63.1 | 180 | == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == |
![]() |
37.1 | 181 | |
182 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 | ||
183 | |||
![]() |
87.1 | 184 | **1)PLC Settings** |
![]() |
37.1 | 185 | |
186 | |**Item**|**Settings**|**Note** | ||
![]() |
85.1 | 187 | |Protocol|Allen-Bradlley DF1 Advanced| |
![]() |
37.1 | 188 | |Connection|RS232| |
189 | |Baud rate|19200| | ||
190 | |Data bit|8| | ||
191 | |Parity|None| | ||
192 | |Stop bit|1| | ||
193 | |PLC station No.|1| | ||
194 | |||
![]() |
87.1 | 195 | **2)Address List** |
![]() |
37.1 | 196 | |
197 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
198 | |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| | ||
199 | |O|O d.d|0.0~~255.15| | ||
200 | |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
201 | |S|S d.d|0.0~~255.15| | ||
202 | |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
203 | |(% rowspan="9" %)Word|S|S d|0~~255| | ||
204 | |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) | ||
205 | |TP|TP nnhh|0~~ffff | ||
206 | |CS|CS nnhh|0~~ffff | ||
207 | |CP|CP nnhh|0~~ffff | ||
208 | |N|N nnhh|0~~ffff | ||
209 | |C|C nnhh|0~~ffff | ||
210 | |T|T nnhh|0~~ffff | ||
211 | |R|R nnhh|0~~ffff | ||
212 | |||
![]() |
86.1 | 213 | **3)Configure the communication protocol**[[image:image-20220824152928-1.png]] |
![]() |
85.1 | 214 | |
![]() |
87.1 | 215 | **4)Configure the communication protocol** |
![]() |
37.1 | 216 | |
217 | [[image:image-20220824110724-1.png]] | ||
218 | |||
![]() |
63.1 | 219 | == **CompactLogix Protocol** == |
![]() |
37.1 | 220 | |
![]() |
11.1 | 221 | ((( |
![]() |
16.1 | 222 | ((( |
![]() |
38.1 | 223 | This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. |
![]() |
16.1 | 224 | ))) |
![]() |
11.1 | 225 | ))) |
226 | |||
227 | ((( | ||
![]() |
15.1 | 228 | (% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) |
229 | ((( | ||
230 | **Software configuration of PLC** | ||
![]() |
11.1 | 231 | ))) |
232 | |||
![]() |
15.1 | 233 | (% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) |
![]() |
11.1 | 234 | ((( |
![]() |
15.1 | 235 | **1)PLC programming software** |
236 | ))) | ||
![]() |
11.1 | 237 | |
![]() |
17.1 | 238 | [[image:image-20220714162600-1.png]] |
![]() |
11.1 | 239 | |
![]() |
15.1 | 240 | (% class="wikigeneratedid" id="HNewPLCproject" %) |
![]() |
11.1 | 241 | ((( |
![]() |
15.1 | 242 | **2)New PLC project** |
![]() |
11.1 | 243 | ))) |
244 | |||
245 | ((( | ||
![]() |
16.1 | 246 | ((( |
![]() |
15.1 | 247 | Click New Project and select the PLC model. |
![]() |
11.1 | 248 | ))) |
![]() |
16.1 | 249 | ))) |
![]() |
11.1 | 250 | |
251 | ((( | ||
![]() |
17.1 | 252 | [[image:image-20220714162617-2.png]] |
![]() |
11.1 | 253 | ))) |
254 | |||
255 | ((( | ||
![]() |
17.1 | 256 | |
![]() |
16.1 | 257 | |
![]() |
17.1 | 258 | [[image:image-20220714162652-4.png]] |
![]() |
11.1 | 259 | ))) |
260 | |||
261 | ((( | ||
![]() |
15.1 | 262 | (% class="wikigeneratedid" id="HSetEthernetparameters" %) |
263 | ((( | ||
264 | **3)Set Ethernet parameters** | ||
265 | ))) | ||
![]() |
11.1 | 266 | |
267 | ((( | ||
![]() |
15.1 | 268 | ((( |
![]() |
16.1 | 269 | ((( |
![]() |
11.1 | 270 | Follow the steps below to configure Ethernet parameters |
271 | ))) | ||
![]() |
15.1 | 272 | ))) |
![]() |
16.1 | 273 | ))) |
![]() |
11.1 | 274 | |
275 | ((( | ||
![]() |
15.1 | 276 | ((( |
![]() |
16.1 | 277 | ((( |
![]() |
11.1 | 278 | PLC IP address:192.168.40.101 |
279 | ))) | ||
![]() |
15.1 | 280 | ))) |
![]() |
16.1 | 281 | ))) |
![]() |
11.1 | 282 | |
283 | ((( | ||
![]() |
15.1 | 284 | ((( |
![]() |
16.1 | 285 | ((( |
![]() |
11.1 | 286 | default gateway:192.168.40.1 |
287 | ))) | ||
![]() |
15.1 | 288 | ))) |
![]() |
16.1 | 289 | ))) |
![]() |
11.1 | 290 | |
291 | ((( | ||
![]() |
15.1 | 292 | ((( |
![]() |
16.1 | 293 | ((( |
![]() |
11.1 | 294 | subnet mask:255.255.255.0 |
295 | ))) | ||
![]() |
15.1 | 296 | ))) |
![]() |
16.1 | 297 | ))) |
![]() |
11.1 | 298 | |
299 | ((( | ||
![]() |
17.1 | 300 | [[image:image-20220714162713-5.png]] |
![]() |
11.1 | 301 | ))) |
302 | |||
303 | ((( | ||
304 | |||
305 | ))) | ||
306 | |||
307 | ((( | ||
![]() |
15.1 | 308 | (% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) |
309 | ((( | ||
310 | **V-box software configuration** | ||
311 | ))) | ||
![]() |
11.1 | 312 | |
![]() |
15.1 | 313 | (% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) |
314 | ((( | ||
315 | **1)V-box programming software** | ||
316 | ))) | ||
![]() |
11.1 | 317 | |
![]() |
15.1 | 318 | (% class="wikigeneratedid" %) |
319 | ((( | ||
![]() |
17.1 | 320 | [[image:image-20220714162725-6.png]] |
![]() |
15.1 | 321 | ))) |
![]() |
11.1 | 322 | |
![]() |
15.1 | 323 | (% class="wikigeneratedid" id="HConfiguredevicenetwork" %) |
324 | ((( | ||
325 | **2)Configure device network** | ||
326 | ))) | ||
![]() |
11.1 | 327 | |
328 | ((( | ||
![]() |
15.1 | 329 | ((( |
![]() |
16.1 | 330 | ((( |
![]() |
11.1 | 331 | Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. |
332 | ))) | ||
![]() |
16.1 | 333 | |
334 | ((( | ||
335 | In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection | ||
![]() |
15.1 | 336 | ))) |
![]() |
16.1 | 337 | ))) |
338 | ))) | ||
![]() |
11.1 | 339 | |
340 | ((( | ||
![]() |
15.1 | 341 | ((( |
![]() |
17.1 | 342 | [[image:image-20220714162737-7.png]] |
![]() |
16.1 | 343 | |
344 | |||
![]() |
11.1 | 345 | ))) |
346 | ))) | ||
347 | ))) | ||
348 | ))) | ||
349 | |||
![]() |
15.1 | 350 | (% class="wikigeneratedid" id="HV-netadddevice" %) |
![]() |
11.1 | 351 | ((( |
![]() |
15.1 | 352 | **3)V-net add device** |
![]() |
11.1 | 353 | ))) |
![]() |
15.1 | 354 | ))) |
![]() |
11.1 | 355 | |
356 | ((( | ||
![]() |
16.1 | 357 | ((( |
![]() |
21.1 | 358 | Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] |
![]() |
11.1 | 359 | ))) |
360 | |||
361 | |||
362 | ))) | ||
363 | |||
364 | ((( | ||
![]() |
15.1 | 365 | (% class="wikigeneratedid" id="HSetcommunicationportparameters" %) |
366 | ((( | ||
367 | **4)Set communication port parameters** | ||
368 | ))) | ||
![]() |
11.1 | 369 | |
![]() |
16.1 | 370 | ((( |
371 | In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. | ||
![]() |
11.1 | 372 | ))) |
373 | |||
![]() |
17.1 | 374 | [[image:image-20220714162805-9.png]] |
![]() |
16.1 | 375 | ))) |
376 | |||
377 | ((( | ||
![]() |
11.1 | 378 | The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. |
![]() |
16.1 | 379 | ))) |
![]() |
11.1 | 380 | |
![]() |
97.1 | 381 | [[image:image-20220824164346-1.png]] |
![]() |
11.1 | 382 | |
383 | |||
![]() |
16.1 | 384 | ((( |
![]() |
22.1 | 385 | After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] |
![]() |
16.1 | 386 | ))) |
![]() |
14.1 | 387 | |
![]() |
16.1 | 388 | (% class="wikigeneratedid" id="HEngineeringproduction" %) |
389 | ((( | ||
390 | **5)Engineering production** | ||
391 | ))) | ||
![]() |
14.1 | 392 | |
![]() |
16.1 | 393 | (% class="wikigeneratedid" %) |
394 | ((( | ||
395 | ((( | ||
396 | According to your own needs, use the V-NET client software to edit the required data monitoring points. | ||
397 | ))) | ||
![]() |
14.1 | 398 | |
![]() |
17.1 | 399 | [[image:image-20220714162841-12.png]] |
![]() |
14.1 | 400 | |
![]() |
16.1 | 401 | |
402 | ((( | ||
403 | **hardware connection** | ||
404 | ))) | ||
405 | ))) | ||
406 | |||
407 | ((( | ||
408 | **1)Hardware wiring diagram** | ||
409 | ))) | ||
410 | |||
411 | ((( | ||
412 | ((( | ||
413 | This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: | ||
414 | ))) | ||
415 | |||
![]() |
17.1 | 416 | [[image:image-20220714162856-13.png]] |
![]() |
16.1 | 417 | |
418 | ((( | ||
![]() |
41.1 | 419 | The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. |
![]() |
26.1 | 420 | |
421 | |||
422 | == **Allen-Bradley Ethernet DF1** == | ||
423 | |||
424 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] | ||
425 | |||
426 | |||
427 | = **Siemens PLC** = | ||
![]() |
61.1 | 428 | |
![]() |
63.1 | 429 | == **S7-200 Smart Ethernet Protocol** == |
![]() |
61.1 | 430 | |
431 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] | ||
![]() |
88.1 | 432 | |
433 | |||
![]() |
99.1 | 434 | == **S7-300 Ethernet Protocol** == |
![]() |
88.1 | 435 | |
436 | Supported Series: Siemens S7-300 series PLC | ||
437 | |||
![]() |
90.1 | 438 | **1)PLC Setting** |
![]() |
88.1 | 439 | |
440 | |**Items**|**Settings**|**Note** | ||
441 | |Protocol|Simens S7-300 Ethernet| | ||
442 | |Connection|Ethernet| | ||
443 | |Port No.|102| | ||
444 | |PLC station No.|2|Need to be same as the PLC setting | ||
445 | |||
![]() |
90.1 | 446 | **2)Address List** |
![]() |
88.1 | 447 | |
448 | |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** | ||
449 | |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| | ||
450 | |Q|Q|Q ddddd.o|0.0~~99999.7| | ||
451 | |M|M|M ddddd.o|0.0~~99999.7| | ||
452 | |DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( | ||
453 | nn: block number; | ||
454 | |||
455 | dddd: address; | ||
![]() |
16.1 | 456 | ))) |
![]() |
88.1 | 457 | |(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| |
458 | |Q|QW|QW ddddd|0~~99999| | ||
459 | |(% rowspan="3" %)M|MB|MB ddddd|0~~99999| | ||
460 | |MW|MW ddddd|0~~99999|((( | ||
461 | MW0=MB(0~~1) | ||
462 | |||
463 | MW2=MB(2~~3) | ||
464 | |||
465 | Address value is a multiple of 2 | ||
![]() |
16.1 | 466 | ))) |
![]() |
88.1 | 467 | |MD|MD ddddd|0~~99999|((( |
468 | MD0=MB(0~~3) | ||
![]() |
16.1 | 469 | |
![]() |
88.1 | 470 | MD4=MB(4~~7) |
471 | |||
472 | Address value is a multiple of 4 | ||
473 | ))) | ||
474 | |(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( | ||
475 | nn: block number; | ||
476 | |||
477 | dddd: address | ||
478 | ))) | ||
479 | |DBxDBW|DBxDBW nndddd|0~~99999999 | ||
480 | |DBxDBD|DBxDBD nndddd|0~~99999999 | ||
481 | |||
![]() |
90.1 | 482 | **3)Configure the communication protocol** |
![]() |
88.1 | 483 | |
![]() |
90.1 | 484 | [[image:image-20220824161345-1.png]] |
![]() |
88.1 | 485 | |
![]() |
96.1 | 486 | **4)Cable Wiring** |
![]() |
88.1 | 487 | |
![]() |
90.1 | 488 | [[image:image-20220824161450-2.png]] |
![]() |
88.1 | 489 | ))) |
490 | ))) | ||
491 | |||
![]() |
63.1 | 492 | == **S7-1200 Ethernet Protocol** == |
![]() |
1.1 | 493 | |
494 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] | ||
495 | |||
![]() |
93.1 | 496 | == **S7-XXX Ethernet Protocol** == |
![]() |
91.1 | 497 | |
498 | Supported Series: Siemens S7-400, S7-1200 and S7-1500 | ||
499 | |||
![]() |
95.1 | 500 | **1)PLC Setting** |
![]() |
91.1 | 501 | |
502 | |=**Items**|=**Settings**|=**Note** | ||
503 | |Protocol|Siemens S7-XXX| | ||
504 | |Connection|Ethernet| | ||
505 | |Port No.|102| | ||
506 | |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| | ||
507 | |HMI No.|Rack (Default as 0)| | ||
508 | |||
![]() |
94.1 | 509 | Slot from TIA Portal is equal to Device No. of V-net |
![]() |
91.1 | 510 | |
![]() |
94.1 | 511 | Rack from TIA Portal is equal to HMI No. of V-net |
![]() |
91.1 | 512 | |
![]() |
92.1 | 513 | [[image:image-20220824162459-3.png]] |
![]() |
91.1 | 514 | |
![]() |
94.1 | 515 | [[image:image-20220824163305-2.png]] |
516 | |||
![]() |
95.1 | 517 | **2)Address List** |
![]() |
91.1 | 518 | |
519 | |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** | ||
520 | |(% rowspan="4" %)Bit|I|I|M d.o|((( | ||
521 | d:0~-~-9999 | ||
522 | |||
523 | o:0-7 | ||
524 | )))| | ||
525 | |Q|Q|Q d.o|((( | ||
526 | d:0~-~-9999 | ||
527 | |||
528 | o:0-7 | ||
529 | )))| | ||
530 | |M|M|M d.o|((( | ||
531 | d:0~-~-9999 | ||
532 | |||
533 | o:0-7 | ||
534 | )))| | ||
535 | |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( | ||
536 | nn:0-9999, | ||
537 | |||
538 | dddd:0-9999, | ||
539 | |||
540 | o:0-7 | ||
541 | )))|((( | ||
542 | nn:DB No. | ||
543 | |||
544 | dddd:address value | ||
545 | |||
546 | o: digit address | ||
547 | ))) | ||
548 | |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| | ||
549 | |M|MW|MW d|d:0-99999|((( | ||
550 | MW0=MB(0~~1) | ||
551 | |||
552 | MW2=MB(2~~3) | ||
553 | |||
554 | Address value is a multiple of 2 | ||
555 | ))) | ||
556 | |M|MD|MD d|d:0-99999|((( | ||
557 | MD0=MB(0~~3) | ||
558 | |||
559 | MD4=MB(4~~7) | ||
560 | |||
561 | Address value is a multiple of 4 | ||
562 | ))) | ||
563 | |I|IW|IW d|d:0-99999| | ||
564 | |Q|QW|QW d|d:0-99999| | ||
565 | |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( | ||
566 | nn:0-9999 | ||
567 | |||
568 | dddd:0-9999 | ||
569 | )))|((( | ||
570 | nn:DB No. | ||
571 | |||
572 | dddd:address value | ||
573 | ))) | ||
574 | |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( | ||
575 | nn:0-9999 | ||
576 | |||
577 | dddd:0-9999 | ||
578 | )))|((( | ||
579 | nn:DB No. | ||
580 | |||
581 | dddd:address value | ||
582 | |||
583 | Address value is a multiple of 2 | ||
584 | ))) | ||
585 | |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( | ||
586 | nn:0-9999 | ||
587 | |||
588 | dddd:0-9999 | ||
589 | )))|((( | ||
590 | nn:DB No. | ||
591 | |||
592 | dddd:address value | ||
593 | |||
594 | Address value is a multiple of 4 | ||
595 | ))) | ||
596 | |||
![]() |
95.1 | 597 | **3)Configure the communication protocol** |
![]() |
91.1 | 598 | |
![]() |
94.1 | 599 | [[image:image-20220824163448-3.png]] |
![]() |
91.1 | 600 | |
601 | **✎Note:** | ||
602 | |||
![]() |
94.1 | 603 | * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. |
604 | * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. | ||
![]() |
91.1 | 605 | |
![]() |
95.1 | 606 | **4)Cable Wiring** |
![]() |
91.1 | 607 | |
![]() |
92.1 | 608 | [[image:image-20220824162342-2.png]] |
![]() |
91.1 | 609 | |
![]() |
98.1 | 610 | |
![]() |
56.1 | 611 | = **Mitsubishi PLC** = |
612 | |||
![]() |
103.1 | 613 | == **FX2N Serial Protocol** == |
614 | |||
615 | |||
616 | |||
![]() |
102.1 | 617 | == **FX3U Serial Protocol** == |
![]() |
56.1 | 618 | |
619 | |||
![]() |
103.1 | 620 | == **FX5U Serial Protocol** == |
621 | |||
622 | |||
![]() |
100.1 | 623 | == **FX5U Ethernet Protocol** == |
624 | |||
625 | Mitsubishi FX5U series PLC | ||
626 | |||
627 | **HMI Settings** | ||
628 | |||
629 | |**Items**|**Settings**|**Note** | ||
630 | |Protocol|Mitsubishi FX5U| | ||
631 | |Connection|Ethernet| | ||
632 | |Port No.|5002|Must be the same as the PLC setting | ||
633 | |PLC station No.|0| | ||
634 | |||
635 | **Address List** | ||
636 | |||
637 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
638 | |(% rowspan="15" %)Bit|X|X|X o|0~~303237| | ||
639 | |Y|Y|Y o|0~~303237| | ||
640 | |M|M|M d|0~~99999| | ||
641 | |B|B|B h|0~~7FFF| | ||
642 | |F|F|F d|0~~32767| | ||
643 | |SB|SB|SB h|0~~7FFF| | ||
644 | |TS|TS|TS d|0~~1023| | ||
645 | |TC|TC|TC d|0~~1023| | ||
646 | |STS|STS|STS d|0~~1023| | ||
647 | |STC|STC|STS d|0~~1023| | ||
648 | |CS|CS|CS d|0~~1023| | ||
649 | |CC|CC|CC d|0~~1023| | ||
650 | |SM|SM|SM d|0~~9999| | ||
651 | |L|L|L d|0~~32767| | ||
652 | |S|S|S d|0~~4095| | ||
653 | |(% rowspan="9" %)Word|W|W|W h|0~~3FF| | ||
654 | |TN|TN|TN d|0~~1023| | ||
655 | |STN|STN|STN d|0~~1023| | ||
656 | |CN|CN|CN d|0~~1023| | ||
657 | |R|R|R d|0~~32767| | ||
658 | |SW|SW|SW h|0~~7FFF| | ||
659 | |Z|Z|Z d|0~~23| | ||
660 | |D|D|D d|0~~7999| | ||
661 | |SD|SD|SD d|0~~11999| | ||
662 | |||
663 | **PLC Settings (GX Works 3)** | ||
664 | |||
665 | Find the [Ethernet port] in the navigation area. | ||
666 | |||
667 | (% style="text-align:center" %) | ||
668 | [[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] | ||
669 | |||
670 | Select [Own Node Settings] in the [Setting Item List]; | ||
671 | |||
672 | Set [IP Address], [Subnet Mask], [Default Gateway]; | ||
673 | |||
674 | Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; | ||
675 | |||
676 | (% style="text-align:center" %) | ||
677 | [[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] | ||
678 | |||
679 | Select [SLMP Connection Module] and add into host station as below picture shows; | ||
680 | |||
681 | Set Port number as 5002 (this is necessary settings); | ||
682 | |||
683 | Click [Close with Reflecting the Setting] to save and close window; | ||
684 | |||
685 | (% style="text-align:center" %) | ||
686 | [[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] | ||
687 | |||
688 | Click [Apply] to completed Etherenet settings; | ||
689 | |||
690 | Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. | ||
691 | |||
692 | (% style="text-align:center" %) | ||
693 | [[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] | ||
694 | |||
695 | **Cable Wiring** | ||
696 | |||
697 | (% style="text-align:center" %) | ||
698 | [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] | ||
699 | |||
![]() |
26.1 | 700 | = **Delta PLC** = |
701 | |||
![]() |
64.1 | 702 | == **DVP Ethernet Protocol** == |
![]() |
1.1 | 703 | |
704 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] | ||
705 | |||
![]() |
63.1 | 706 | == **DVP Serial Protocol** == |
![]() |
1.1 | 707 | |
708 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] | ||
709 | |||
![]() |
48.1 | 710 | = **Omron PLC** = |
711 | |||
![]() |
65.1 | 712 | == **CP1 Series Protocol** == |
![]() |
7.1 | 713 | |
![]() |
8.1 | 714 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] |
![]() |
7.1 | 715 | |
![]() |
65.1 | 716 | == **CJ2M Series Protocol** == |
![]() |
7.1 | 717 | |
![]() |
8.1 | 718 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] |
![]() |
7.1 | 719 | |
![]() |
50.1 | 720 | = **Modbus RTU** = |
721 | |||
![]() |
53.1 | 722 | == **V-BOX as master** == |
![]() |
50.1 | 723 | |
724 | Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, | ||
725 | |||
726 | (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity | ||
727 | |||
728 | (% style="text-align:center" %) | ||
729 | [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] | ||
730 | |||
![]() |
53.1 | 731 | == **V-BOX as slave** == |
![]() |
50.1 | 732 | |
733 | Select the protocol “(% class="mark" %)**Modbus RTU Master”**, | ||
734 | |||
735 | (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity | ||
736 | |||
737 | (% style="text-align:center" %) | ||
738 | [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] | ||
739 | |||
740 | **Address List** | ||
741 | |||
742 | (% class="table-bordered" %) | ||
743 | |**Type**|**Register**|**Function code & Description** | ||
744 | |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) | ||
745 | |06 (write single register: write a binary value to a holding register) | ||
746 | |10 (write values to multiple addresses ) | ||
747 | |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) | ||
748 | |06 (write single register: write a binary value to a holding register) | ||
749 | |10 (write values to multiple addresses ) | ||
750 | |(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) | ||
751 | |06 (write single register: write a binary value to a holding register) | ||
752 | |10 (write values to multiple addresses ) | ||
753 | |(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) | ||
754 | |10 (write values to multiple addresses ) | ||
755 | |(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) | ||
756 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
757 | |0F (Write multiple bits, ie write continuously) | ||
758 | |(% rowspan="3" %)1|02 (Read the input state) | ||
759 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
760 | |0F (Write multiple bits) | ||
761 | |(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) | ||
762 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
763 | |0F (Write multiple bits) | ||
764 | |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) | ||
765 | |0F (Write multiple bits) | ||
766 | |||
![]() |
55.1 | 767 | == **communicate with VB inverter** == |
![]() |
52.1 | 768 | |
769 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] | ||
770 | |||
![]() |
51.1 | 771 | = **User define protocol** = |
![]() |
1.1 | 772 | |
![]() |
19.1 | 773 | More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] |
![]() |
1.1 | 774 | |
![]() |
10.1 | 775 | == **Read the temperature sensor.** == |
![]() |
1.1 | 776 | |
777 | the commond format is as beliow: | ||
778 | |||
779 | Send commond:01 03 02 00 00 03 04 73 | ||
780 | |||
781 | Feedback commond:01 03 06 07 F7 0E 7E B7 35 | ||
782 | |||
783 | Temperature data:07 F7,desimal = 2039,it means temperature is 20.39℃. | ||
784 | |||
785 | Humidity data:0E 7E,desimal = 3710, it mean humidity is 37.10%RH. | ||
786 | |||
787 | Script Demo: | ||
788 | |||
789 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-- | ||
790 | |||
791 | function com.main() | ||
792 | ~-~-dosomething | ||
793 | openPlc() | ||
794 | end | ||
795 | function openPlc() | ||
796 | if obj then | ||
797 | ~-~- If the serial port opened,then read/write data by timing | ||
798 | |||
799 | local wri = string.pack(">HHHH",0X0103,0X0200,0X0003,0X0473) | ||
800 | local arr = reading(wri) | ||
801 | ~-~- if arr ~~=nil then | ||
802 | ~-~- if arr[1] ==33 and arr[2] ==v[2][2] and arr[3] ==v[2][3] then | ||
803 | ~-~- local A = arr[4]*256 | ||
804 | ~-~- local B = A+arr[5] | ||
805 | ~-~- addr_setword(v[1],B) | ||
806 | ~-~- end | ||
807 | ~-~- end | ||
808 | |||
809 | else | ||
810 | ~-~-judge if there is a serial object, then initialize and open the serial port | ||
811 | local configs = { | ||
812 | name = 'COM1', ~-~-Select serial port COM1 | ||
813 | mode = 485, ~-~-Communication mode RS485 | ||
814 | baud_rate = 9600, ~-~-Baud rate 9600 | ||
815 | stop_bit = 1, ~-~-stop bit 1 | ||
816 | data_len = 8, ~-~-data length 8 | ||
817 | check_bit = 'NONE', ~-~-no parity | ||
818 | |||
819 | } | ||
820 | obj,err = serial.open(configs) ~-~-Open serial port | ||
821 | if not obj then | ||
822 | print("serial open :failed", err) ~-~- Open serial port failed | ||
823 | end | ||
824 | end | ||
825 | end | ||
826 | |||
827 | function reading(wri) | ||
828 | obj:flush() ~-~- Clear serial port | ||
829 | obj:write(wri) ~-~- Write serial port | ||
830 | print(string.byte(wri,1,#wri)) | ||
831 | obj:flush() ~-~- Clear serial port | ||
832 | local readed =obj:read(9,1000) ~-~- Read 9 bytes, timeout 1 second | ||
833 | if readed and readed ~~= "" then | ||
834 | ~-~- judge that a non-empty string is read | ||
835 | print(string.byte(readed,1,#readed)) | ||
836 | a={string.byte(readed, 1, #readed)} | ||
837 | if nil ~~= a[4] and nil ~~= a[5] and nil ~~= a[6] and nil ~~= a[7] then | ||
838 | a1=a[4]*256+a[5] | ||
839 | a2=a[6]*256+a[7] | ||
840 | addr_setword("@HDW0",a1) | ||
841 | addr_setword("@HDW1",a2) | ||
842 | end | ||
843 | return {string.byte(readed, 1, #readed)} | ||
844 | elseif readed == nil then | ||
845 | print("serial read err:", err or "") | ||
846 | return nil | ||
847 | end | ||
848 | return nil | ||
849 | end | ||
850 | |||
851 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~- |