Wiki source code of 1 Communication
Version 143.1 by Ben on 2022/08/31 16:10
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
136.1 | 1 | = Create communication with WECON PLC = |
![]() |
1.1 | 2 | |
![]() |
123.1 | 3 | == **LX3V Serial Protocol** == |
![]() |
31.1 | 4 | |
![]() |
123.1 | 5 | Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM |
![]() |
1.1 | 6 | |
![]() |
123.1 | 7 | **1)V-BOX setting** |
![]() |
1.1 | 8 | |
![]() |
123.1 | 9 | |**Item**|**Settings**|**Note** |
10 | |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| | ||
11 | |Connection|RS422/RS485| | ||
12 | |Baud rate|9600| | ||
13 | |Data bit|7| | ||
14 | |Parity|EVEN| | ||
15 | |Stop bit|1| | ||
16 | |PLC station No.|1| | ||
![]() |
1.1 | 17 | |
![]() |
123.1 | 18 | **2)Address List** |
![]() |
20.1 | 19 | |
![]() |
125.1 | 20 | |
21 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
22 | |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| | ||
![]() |
119.1 | 23 | |Y|Y|Y o|0~~303237| |
24 | |M|M|M d|0~~99999| | ||
![]() |
125.1 | 25 | |T|T|T d|0~~99999| |
26 | |C|C|C d|0~~99999| | ||
27 | |S|S|S d|0~~99999| | ||
28 | |(% rowspan="8" %)Word|X|X|Xo|0~~303237| | ||
![]() |
119.1 | 29 | |Y|Y|Y o|0~~303237| |
30 | |M|M|M d|0~~99999| | ||
![]() |
125.1 | 31 | |T|T|T d|0~~99999| |
32 | |C|C|C d|0~~199| | ||
33 | |D|D|D d|0~~7999| | ||
34 | |S|S|S d|0~~99999| | ||
35 | |SD|SD|SD d|8000~~9999| | ||
![]() |
20.1 | 36 | |
![]() |
123.1 | 37 | **3)Configure the communication protocol** |
![]() |
20.1 | 38 | |
![]() |
119.1 | 39 | [[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] |
![]() |
80.1 | 40 | |
![]() |
123.1 | 41 | **4)Cable Wiring** |
![]() |
80.1 | 42 | |
![]() |
119.1 | 43 | * **RS422** |
![]() |
20.1 | 44 | |
![]() |
119.1 | 45 | [[image:image-20220824120614-5.png]] |
![]() |
20.1 | 46 | |
![]() |
119.1 | 47 | * **RS485** |
![]() |
68.1 | 48 | |
![]() |
119.1 | 49 | [[image:image-20220824120524-3.png]] |
![]() |
68.1 | 50 | |
![]() |
119.1 | 51 | == **LX5V Serial Protocol** == |
![]() |
28.1 | 52 | |
![]() |
84.1 | 53 | This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. |
![]() |
20.1 | 54 | |
![]() |
119.1 | 55 | **Software configuration of PLC** |
![]() |
20.1 | 56 | |
![]() |
119.1 | 57 | **1)PLC programming software** |
![]() |
20.1 | 58 | |
![]() |
119.1 | 59 | [[image:image-20220824142722-1.png]] |
![]() |
20.1 | 60 | |
![]() |
119.1 | 61 | **2)New PLC project** |
![]() |
20.1 | 62 | |
63 | Click New Project and select the PLC model. | ||
64 | |||
![]() |
119.1 | 65 | [[image:image-20220822172623-2.png]] |
![]() |
20.1 | 66 | |
![]() |
119.1 | 67 | **3)Set Serial port parameters** |
![]() |
20.1 | 68 | |
69 | Follow the steps below to configure Serial port parameters | ||
70 | |||
71 | Baud rate:115200 | ||
72 | |||
73 | Data bit:8 | ||
74 | |||
75 | Stop bit:1 | ||
76 | |||
77 | Parity:No verification | ||
78 | |||
![]() |
119.1 | 79 | [[image:image-20220822172657-3.png]] |
![]() |
20.1 | 80 | |
![]() |
119.1 | 81 | **4)Registers list** |
![]() |
20.1 | 82 | |
![]() |
119.1 | 83 | [[image:image-20220822172730-4.png]] |
![]() |
20.1 | 84 | |
![]() |
119.1 | 85 | **V-BOX software configuration** |
![]() |
28.1 | 86 | |
![]() |
119.1 | 87 | **1)V-BOX programming software** |
![]() |
20.1 | 88 | |
![]() |
119.1 | 89 | [[image:image-20220824104124-1.png]] |
![]() |
20.1 | 90 | |
![]() |
119.1 | 91 | **2)V-NET add device** |
![]() |
20.1 | 92 | |
![]() |
35.1 | 93 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. |
![]() |
20.1 | 94 | |
![]() |
119.1 | 95 | [[image:image-20220824104909-2.png]] |
![]() |
20.1 | 96 | |
![]() |
119.1 | 97 | **3)Set communication port parameters** |
![]() |
20.1 | 98 | |
99 | Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. | ||
100 | |||
101 | Baud rate:115200 | ||
102 | |||
103 | Data bit:8 | ||
104 | |||
105 | Stop bit:1 | ||
106 | |||
107 | Parity:No verification | ||
108 | |||
![]() |
119.1 | 109 | [[image:image-20220824142130-1.png]] |
![]() |
20.1 | 110 | |
![]() |
119.1 | 111 | **hardware connection** |
![]() |
20.1 | 112 | |
![]() |
119.1 | 113 | **1)Hardware wiring diagram** |
![]() |
20.1 | 114 | |
![]() |
119.1 | 115 | [[image:image-20220824142546-2.png]] |
![]() |
28.1 | 116 | |
![]() |
119.1 | 117 | [[image:image-20220824142643-3.png]] |
![]() |
28.1 | 118 | |
![]() |
74.1 | 119 | The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. |
![]() |
20.1 | 120 | |
![]() |
119.1 | 121 | == **LX5V-N Ethernet protocol** == |
![]() |
20.1 | 122 | |
![]() |
77.1 | 123 | This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. |
![]() |
20.1 | 124 | |
![]() |
119.1 | 125 | **Software configuration of PLC** |
![]() |
20.1 | 126 | |
![]() |
119.1 | 127 | **1)PLC programming software** |
![]() |
20.1 | 128 | |
![]() |
119.1 | 129 | [[image:image-20220824142722-1.png]] |
![]() |
20.1 | 130 | |
![]() |
119.1 | 131 | **2)New PLC project** |
![]() |
20.1 | 132 | |
133 | Click New Project and select the PLC model. | ||
134 | |||
![]() |
119.1 | 135 | [[image:image-20220824143613-1.png]] |
![]() |
20.1 | 136 | |
![]() |
119.1 | 137 | **3)Set Ethernet port parameters** |
![]() |
20.1 | 138 | |
139 | Follow the steps below to configure Ethernet parameters | ||
140 | |||
141 | PLC IP address:192.168.39.200 | ||
142 | |||
143 | default gateway:192.168.39.1 | ||
144 | |||
145 | subnet mask:255.255.255.0 | ||
146 | |||
![]() |
119.1 | 147 | [[image:image-20220824143744-2.png]] |
![]() |
20.1 | 148 | |
![]() |
119.1 | 149 | **4)Registers list** |
![]() |
20.1 | 150 | |
![]() |
119.1 | 151 | [[image:image-20220822172730-4.png]] |
![]() |
20.1 | 152 | |
![]() |
119.1 | 153 | (% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** |
![]() |
20.1 | 154 | |
![]() |
119.1 | 155 | **1)V-BOX programming software** |
![]() |
20.1 | 156 | |
![]() |
119.1 | 157 | [[image:image-20220824104124-1.png]] |
![]() |
20.1 | 158 | |
![]() |
119.1 | 159 | **2)V-NET add device** |
![]() |
20.1 | 160 | |
![]() |
74.1 | 161 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. |
![]() |
20.1 | 162 | |
![]() |
119.1 | 163 | [[image:image-20220824104909-2.png]] |
![]() |
20.1 | 164 | |
![]() |
119.1 | 165 | **3)Set communication Protocol** |
![]() |
20.1 | 166 | |
![]() |
74.1 | 167 | Click Communication to configure the LX5V plc protocol and IP address. |
![]() |
20.1 | 168 | |
![]() |
119.1 | 169 | [[image:image-20220824144619-1.png]] |
![]() |
20.1 | 170 | |
![]() |
119.1 | 171 | **hardware connection** |
![]() |
20.1 | 172 | |
![]() |
119.1 | 173 | **1)Hardware wiring diagram** |
![]() |
20.1 | 174 | |
![]() |
119.1 | 175 | [[image:image-20220824151127-2.png]] |
![]() |
20.1 | 176 | |
![]() |
74.1 | 177 | The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. |
![]() |
20.1 | 178 | |
![]() |
137.1 | 179 | = Create communication with **Rockwell PLC** = |
![]() |
22.1 | 180 | |
![]() |
119.1 | 181 | == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == |
![]() |
37.1 | 182 | |
183 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 | ||
184 | |||
![]() |
119.1 | 185 | **1)PLC Settings** |
![]() |
37.1 | 186 | |
![]() |
119.1 | 187 | |**Item**|**Settings**|**Note** |
188 | |Protocol|Allen-Bradlley DF1 Advanced| | ||
189 | |Connection|RS232| | ||
190 | |Baud rate|19200| | ||
191 | |Data bit|8| | ||
192 | |Parity|None| | ||
193 | |Stop bit|1| | ||
194 | |PLC station No.|1| | ||
![]() |
37.1 | 195 | |
![]() |
119.1 | 196 | **2)Address List** |
![]() |
37.1 | 197 | |
![]() |
119.1 | 198 | |**Type**|**Device registers**|**Format**|**Range**|**Note** |
199 | |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| | ||
200 | |O|O d.d|0.0~~255.15| | ||
201 | |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
202 | |S|S d.d|0.0~~255.15| | ||
203 | |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
204 | |(% rowspan="9" %)Word|S|S d|0~~255| | ||
205 | |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) | ||
206 | |TP|TP nnhh|0~~ffff | ||
207 | |CS|CS nnhh|0~~ffff | ||
208 | |CP|CP nnhh|0~~ffff | ||
209 | |N|N nnhh|0~~ffff | ||
210 | |C|C nnhh|0~~ffff | ||
211 | |T|T nnhh|0~~ffff | ||
212 | |R|R nnhh|0~~ffff | ||
![]() |
37.1 | 213 | |
![]() |
119.1 | 214 | **3)Configure the communication protocol**[[image:image-20220824152928-1.png]] |
![]() |
85.1 | 215 | |
![]() |
119.1 | 216 | **4)Configure the communication protocol** |
![]() |
37.1 | 217 | |
![]() |
119.1 | 218 | [[image:image-20220824110724-1.png]] |
![]() |
37.1 | 219 | |
![]() |
139.1 | 220 | == **Micro850_FreeTag Protocol** == |
![]() |
37.1 | 221 | |
![]() |
11.1 | 222 | ((( |
![]() |
16.1 | 223 | ((( |
![]() |
38.1 | 224 | This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. |
![]() |
16.1 | 225 | ))) |
![]() |
11.1 | 226 | ))) |
227 | |||
228 | ((( | ||
![]() |
15.1 | 229 | (% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) |
230 | ((( | ||
![]() |
119.1 | 231 | **Software configuration of PLC** |
![]() |
11.1 | 232 | ))) |
233 | |||
![]() |
15.1 | 234 | (% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) |
![]() |
11.1 | 235 | ((( |
![]() |
119.1 | 236 | **1)PLC programming software** |
![]() |
15.1 | 237 | ))) |
![]() |
11.1 | 238 | |
![]() |
119.1 | 239 | [[image:image-20220714162600-1.png]] |
![]() |
11.1 | 240 | |
![]() |
15.1 | 241 | (% class="wikigeneratedid" id="HNewPLCproject" %) |
![]() |
11.1 | 242 | ((( |
![]() |
119.1 | 243 | **2)New PLC project** |
![]() |
11.1 | 244 | ))) |
245 | |||
246 | ((( | ||
![]() |
16.1 | 247 | ((( |
![]() |
15.1 | 248 | Click New Project and select the PLC model. |
![]() |
11.1 | 249 | ))) |
![]() |
16.1 | 250 | ))) |
![]() |
11.1 | 251 | |
252 | ((( | ||
![]() |
119.1 | 253 | [[image:image-20220714162617-2.png]] |
![]() |
11.1 | 254 | ))) |
255 | |||
256 | ((( | ||
![]() |
17.1 | 257 | |
![]() |
16.1 | 258 | |
![]() |
119.1 | 259 | [[image:image-20220714162652-4.png]] |
![]() |
11.1 | 260 | ))) |
261 | |||
262 | ((( | ||
![]() |
15.1 | 263 | (% class="wikigeneratedid" id="HSetEthernetparameters" %) |
264 | ((( | ||
![]() |
119.1 | 265 | **3)Set Ethernet parameters** |
![]() |
15.1 | 266 | ))) |
![]() |
11.1 | 267 | |
268 | ((( | ||
![]() |
15.1 | 269 | ((( |
![]() |
16.1 | 270 | ((( |
![]() |
11.1 | 271 | Follow the steps below to configure Ethernet parameters |
272 | ))) | ||
![]() |
15.1 | 273 | ))) |
![]() |
16.1 | 274 | ))) |
![]() |
11.1 | 275 | |
276 | ((( | ||
![]() |
15.1 | 277 | ((( |
![]() |
16.1 | 278 | ((( |
![]() |
11.1 | 279 | PLC IP address:192.168.40.101 |
280 | ))) | ||
![]() |
15.1 | 281 | ))) |
![]() |
16.1 | 282 | ))) |
![]() |
11.1 | 283 | |
284 | ((( | ||
![]() |
15.1 | 285 | ((( |
![]() |
16.1 | 286 | ((( |
![]() |
11.1 | 287 | default gateway:192.168.40.1 |
288 | ))) | ||
![]() |
15.1 | 289 | ))) |
![]() |
16.1 | 290 | ))) |
![]() |
11.1 | 291 | |
292 | ((( | ||
![]() |
15.1 | 293 | ((( |
![]() |
16.1 | 294 | ((( |
![]() |
11.1 | 295 | subnet mask:255.255.255.0 |
296 | ))) | ||
![]() |
15.1 | 297 | ))) |
![]() |
16.1 | 298 | ))) |
![]() |
11.1 | 299 | |
300 | ((( | ||
![]() |
119.1 | 301 | [[image:image-20220714162713-5.png]] |
![]() |
11.1 | 302 | ))) |
303 | |||
304 | ((( | ||
305 | |||
306 | ))) | ||
307 | |||
308 | ((( | ||
![]() |
15.1 | 309 | (% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) |
310 | ((( | ||
![]() |
119.1 | 311 | **V-box software configuration** |
![]() |
15.1 | 312 | ))) |
![]() |
11.1 | 313 | |
![]() |
15.1 | 314 | (% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) |
315 | ((( | ||
![]() |
119.1 | 316 | **1)V-box programming software** |
![]() |
15.1 | 317 | ))) |
![]() |
11.1 | 318 | |
![]() |
15.1 | 319 | (% class="wikigeneratedid" %) |
320 | ((( | ||
![]() |
119.1 | 321 | [[image:image-20220714162725-6.png]] |
![]() |
15.1 | 322 | ))) |
![]() |
11.1 | 323 | |
![]() |
15.1 | 324 | (% class="wikigeneratedid" id="HConfiguredevicenetwork" %) |
325 | ((( | ||
![]() |
119.1 | 326 | **2)Configure device network** |
![]() |
15.1 | 327 | ))) |
![]() |
11.1 | 328 | |
329 | ((( | ||
![]() |
15.1 | 330 | ((( |
![]() |
16.1 | 331 | ((( |
![]() |
119.1 | 332 | Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. |
![]() |
11.1 | 333 | ))) |
![]() |
16.1 | 334 | |
335 | ((( | ||
336 | In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection | ||
![]() |
15.1 | 337 | ))) |
![]() |
16.1 | 338 | ))) |
339 | ))) | ||
![]() |
11.1 | 340 | |
341 | ((( | ||
![]() |
15.1 | 342 | ((( |
![]() |
119.1 | 343 | [[image:image-20220714162737-7.png]] |
![]() |
16.1 | 344 | |
345 | |||
![]() |
11.1 | 346 | ))) |
347 | ))) | ||
348 | ))) | ||
349 | ))) | ||
350 | |||
![]() |
15.1 | 351 | (% class="wikigeneratedid" id="HV-netadddevice" %) |
![]() |
11.1 | 352 | ((( |
![]() |
119.1 | 353 | **3)V-net add device** |
![]() |
11.1 | 354 | ))) |
![]() |
15.1 | 355 | ))) |
![]() |
11.1 | 356 | |
357 | ((( | ||
![]() |
16.1 | 358 | ((( |
![]() |
119.1 | 359 | Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] |
![]() |
11.1 | 360 | ))) |
361 | |||
362 | |||
363 | ))) | ||
364 | |||
365 | ((( | ||
![]() |
15.1 | 366 | (% class="wikigeneratedid" id="HSetcommunicationportparameters" %) |
367 | ((( | ||
![]() |
119.1 | 368 | **4)Set communication port parameters** |
![]() |
15.1 | 369 | ))) |
![]() |
11.1 | 370 | |
![]() |
16.1 | 371 | ((( |
372 | In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. | ||
![]() |
11.1 | 373 | ))) |
374 | |||
![]() |
119.1 | 375 | [[image:image-20220714162805-9.png]] |
![]() |
16.1 | 376 | ))) |
377 | |||
378 | ((( | ||
![]() |
11.1 | 379 | The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. |
![]() |
16.1 | 380 | ))) |
![]() |
11.1 | 381 | |
![]() |
119.1 | 382 | [[image:image-20220824164346-1.png]] |
![]() |
11.1 | 383 | |
384 | |||
![]() |
16.1 | 385 | ((( |
![]() |
119.1 | 386 | After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] |
![]() |
16.1 | 387 | ))) |
![]() |
14.1 | 388 | |
![]() |
16.1 | 389 | (% class="wikigeneratedid" id="HEngineeringproduction" %) |
390 | ((( | ||
![]() |
119.1 | 391 | **5)Engineering production** |
![]() |
16.1 | 392 | ))) |
![]() |
14.1 | 393 | |
![]() |
16.1 | 394 | (% class="wikigeneratedid" %) |
395 | ((( | ||
396 | ((( | ||
397 | According to your own needs, use the V-NET client software to edit the required data monitoring points. | ||
398 | ))) | ||
![]() |
14.1 | 399 | |
![]() |
119.1 | 400 | [[image:image-20220714162841-12.png]] |
![]() |
14.1 | 401 | |
![]() |
16.1 | 402 | |
403 | ((( | ||
![]() |
119.1 | 404 | **hardware connection** |
![]() |
16.1 | 405 | ))) |
406 | ))) | ||
407 | |||
408 | ((( | ||
![]() |
119.1 | 409 | **1)Hardware wiring diagram** |
![]() |
16.1 | 410 | ))) |
411 | |||
412 | ((( | ||
413 | ((( | ||
414 | This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: | ||
415 | ))) | ||
416 | |||
![]() |
119.1 | 417 | [[image:image-20220714162856-13.png]] |
![]() |
16.1 | 418 | |
419 | ((( | ||
![]() |
41.1 | 420 | The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. |
![]() |
26.1 | 421 | |
422 | |||
![]() |
119.1 | 423 | == **Allen-Bradley Ethernet DF1** == |
![]() |
26.1 | 424 | |
![]() |
119.1 | 425 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] |
![]() |
26.1 | 426 | |
427 | |||
![]() |
138.1 | 428 | = Create communication with **Siemens PLC** = |
![]() |
61.1 | 429 | |
![]() |
119.1 | 430 | == **S7-200 Smart Ethernet Protocol** == |
![]() |
61.1 | 431 | |
![]() |
119.1 | 432 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] |
![]() |
88.1 | 433 | |
434 | |||
![]() |
119.1 | 435 | == **S7-300 Ethernet Protocol** == |
![]() |
88.1 | 436 | |
437 | Supported Series: Siemens S7-300 series PLC | ||
438 | |||
![]() |
119.1 | 439 | **1)PLC Setting** |
![]() |
88.1 | 440 | |
![]() |
119.1 | 441 | |**Items**|**Settings**|**Note** |
442 | |Protocol|Simens S7-300 Ethernet| | ||
443 | |Connection|Ethernet| | ||
444 | |Port No.|102| | ||
445 | |PLC station No.|2|Need to be same as the PLC setting | ||
![]() |
88.1 | 446 | |
![]() |
119.1 | 447 | **2)Address List** |
![]() |
88.1 | 448 | |
![]() |
119.1 | 449 | |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** |
450 | |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| | ||
451 | |Q|Q|Q ddddd.o|0.0~~99999.7| | ||
452 | |M|M|M ddddd.o|0.0~~99999.7| | ||
453 | |DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( | ||
![]() |
88.1 | 454 | nn: block number; |
455 | |||
456 | dddd: address; | ||
![]() |
16.1 | 457 | ))) |
![]() |
119.1 | 458 | |(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| |
459 | |Q|QW|QW ddddd|0~~99999| | ||
460 | |(% rowspan="3" %)M|MB|MB ddddd|0~~99999| | ||
461 | |MW|MW ddddd|0~~99999|((( | ||
![]() |
88.1 | 462 | MW0=MB(0~~1) |
463 | |||
464 | MW2=MB(2~~3) | ||
465 | |||
466 | Address value is a multiple of 2 | ||
![]() |
16.1 | 467 | ))) |
![]() |
119.1 | 468 | |MD|MD ddddd|0~~99999|((( |
![]() |
88.1 | 469 | MD0=MB(0~~3) |
![]() |
16.1 | 470 | |
![]() |
88.1 | 471 | MD4=MB(4~~7) |
472 | |||
473 | Address value is a multiple of 4 | ||
474 | ))) | ||
![]() |
119.1 | 475 | |(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( |
![]() |
88.1 | 476 | nn: block number; |
477 | |||
478 | dddd: address | ||
479 | ))) | ||
![]() |
119.1 | 480 | |DBxDBW|DBxDBW nndddd|0~~99999999 |
481 | |DBxDBD|DBxDBD nndddd|0~~99999999 | ||
![]() |
88.1 | 482 | |
![]() |
119.1 | 483 | **3)Configure the communication protocol** |
![]() |
88.1 | 484 | |
![]() |
119.1 | 485 | [[image:image-20220824161345-1.png]] |
![]() |
88.1 | 486 | |
![]() |
119.1 | 487 | **4)Cable Wiring** |
![]() |
88.1 | 488 | |
![]() |
119.1 | 489 | [[image:image-20220824161450-2.png]] |
![]() |
88.1 | 490 | ))) |
491 | ))) | ||
492 | |||
![]() |
119.1 | 493 | == **S7-1200 Ethernet Protocol** == |
![]() |
1.1 | 494 | |
![]() |
119.1 | 495 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] |
![]() |
1.1 | 496 | |
![]() |
119.1 | 497 | == **S7-XXX Ethernet Protocol** == |
![]() |
91.1 | 498 | |
499 | Supported Series: Siemens S7-400, S7-1200 and S7-1500 | ||
500 | |||
![]() |
119.1 | 501 | **1)PLC Setting** |
![]() |
91.1 | 502 | |
![]() |
119.1 | 503 | |=**Items**|=**Settings**|=**Note** |
504 | |Protocol|Siemens S7-XXX| | ||
505 | |Connection|Ethernet| | ||
506 | |Port No.|102| | ||
507 | |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| | ||
508 | |HMI No.|Rack (Default as 0)| | ||
![]() |
91.1 | 509 | |
![]() |
94.1 | 510 | Slot from TIA Portal is equal to Device No. of V-net |
![]() |
91.1 | 511 | |
![]() |
94.1 | 512 | Rack from TIA Portal is equal to HMI No. of V-net |
![]() |
91.1 | 513 | |
![]() |
119.1 | 514 | [[image:image-20220824162459-3.png]] |
![]() |
91.1 | 515 | |
![]() |
119.1 | 516 | [[image:image-20220824163305-2.png]] |
![]() |
94.1 | 517 | |
![]() |
119.1 | 518 | **2)Address List** |
![]() |
91.1 | 519 | |
![]() |
119.1 | 520 | |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** |
521 | |(% rowspan="4" %)Bit|I|I|M d.o|((( | ||
![]() |
91.1 | 522 | d:0~-~-9999 |
523 | |||
524 | o:0-7 | ||
525 | )))| | ||
![]() |
119.1 | 526 | |Q|Q|Q d.o|((( |
![]() |
91.1 | 527 | d:0~-~-9999 |
528 | |||
529 | o:0-7 | ||
530 | )))| | ||
![]() |
119.1 | 531 | |M|M|M d.o|((( |
![]() |
91.1 | 532 | d:0~-~-9999 |
533 | |||
534 | o:0-7 | ||
535 | )))| | ||
![]() |
119.1 | 536 | |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( |
![]() |
91.1 | 537 | nn:0-9999, |
538 | |||
539 | dddd:0-9999, | ||
540 | |||
541 | o:0-7 | ||
542 | )))|((( | ||
543 | nn:DB No. | ||
544 | |||
545 | dddd:address value | ||
546 | |||
547 | o: digit address | ||
548 | ))) | ||
![]() |
119.1 | 549 | |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| |
550 | |M|MW|MW d|d:0-99999|((( | ||
![]() |
91.1 | 551 | MW0=MB(0~~1) |
552 | |||
553 | MW2=MB(2~~3) | ||
554 | |||
555 | Address value is a multiple of 2 | ||
556 | ))) | ||
![]() |
119.1 | 557 | |M|MD|MD d|d:0-99999|((( |
![]() |
91.1 | 558 | MD0=MB(0~~3) |
559 | |||
560 | MD4=MB(4~~7) | ||
561 | |||
562 | Address value is a multiple of 4 | ||
563 | ))) | ||
![]() |
119.1 | 564 | |I|IW|IW d|d:0-99999| |
565 | |Q|QW|QW d|d:0-99999| | ||
566 | |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( | ||
![]() |
91.1 | 567 | nn:0-9999 |
568 | |||
569 | dddd:0-9999 | ||
570 | )))|((( | ||
571 | nn:DB No. | ||
572 | |||
573 | dddd:address value | ||
574 | ))) | ||
![]() |
119.1 | 575 | |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( |
![]() |
91.1 | 576 | nn:0-9999 |
577 | |||
578 | dddd:0-9999 | ||
579 | )))|((( | ||
580 | nn:DB No. | ||
581 | |||
582 | dddd:address value | ||
583 | |||
584 | Address value is a multiple of 2 | ||
585 | ))) | ||
![]() |
119.1 | 586 | |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( |
![]() |
91.1 | 587 | nn:0-9999 |
588 | |||
589 | dddd:0-9999 | ||
590 | )))|((( | ||
591 | nn:DB No. | ||
592 | |||
593 | dddd:address value | ||
594 | |||
595 | Address value is a multiple of 4 | ||
596 | ))) | ||
597 | |||
![]() |
119.1 | 598 | **3)Configure the communication protocol** |
![]() |
91.1 | 599 | |
![]() |
119.1 | 600 | [[image:image-20220824163448-3.png]] |
![]() |
91.1 | 601 | |
![]() |
119.1 | 602 | **✎Note:** |
![]() |
91.1 | 603 | |
![]() |
94.1 | 604 | * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. |
605 | * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. | ||
![]() |
91.1 | 606 | |
![]() |
119.1 | 607 | **4)Cable Wiring** |
![]() |
91.1 | 608 | |
![]() |
119.1 | 609 | [[image:image-20220824162342-2.png]] |
![]() |
91.1 | 610 | |
![]() |
138.1 | 611 | = Create communication with **Mitsubishi PLC** = |
![]() |
56.1 | 612 | |
![]() |
119.1 | 613 | == **FX1S,1N,2N Serial Protocol** == |
![]() |
103.1 | 614 | |
![]() |
105.1 | 615 | Supported Series: Mitsubishi FX1S, FX1N, FX2N series |
![]() |
103.1 | 616 | |
![]() |
119.1 | 617 | **1)V-BOX Settings** |
![]() |
103.1 | 618 | |
![]() |
119.1 | 619 | |**Item**|**Settings**|**Note** |
620 | |Protocol|Mitsubishi FX1S/FX1N/FX2N| | ||
621 | |Connection|RS422/RS485/RS232| | ||
622 | |Baud rate|9600~~115200| | ||
623 | |Data bit|7/8| | ||
624 | |Parity|EVEN/Odd/None| | ||
625 | |Stop bit|1/2| | ||
626 | |PLC station No.|1~~255| | ||
![]() |
104.1 | 627 | |
![]() |
119.1 | 628 | **2)Address List** |
![]() |
104.1 | 629 | |
![]() |
119.1 | 630 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
631 | |(% rowspan="7" %)Bit|X|X|Xo|0~~303237| | ||
632 | |Y|Y|Y o|0~~303237| | ||
633 | |M|M|M d|0~~99999| | ||
634 | |T|T|T d|0~~99999| | ||
635 | |C|C|C d|0~~99999| | ||
636 | |S|S|S d|0~~99999| | ||
637 | |SM|SM|SM d|8000~~9999| | ||
638 | |(% rowspan="8" %)Word|X|X|Xo|0~~303237| | ||
639 | |Y|Y|Y o|0~~303237| | ||
640 | |M|M|M d|0~~99999| | ||
641 | |T|T|T d|0~~99999| | ||
642 | |C|C|C d|0~~199| | ||
643 | |D|D|D d|0~~7999| | ||
644 | |S|S|S d|0~~99999| | ||
645 | |SD|SD|SD d|8000~~9999| | ||
![]() |
104.1 | 646 | |
![]() |
119.1 | 647 | **3)Configure the communication protocol** |
![]() |
104.1 | 648 | |
![]() |
119.1 | 649 | [[image:image-20220825102844-3.png]] |
![]() |
106.1 | 650 | |
![]() |
119.1 | 651 | **4)Cable Wiring** |
![]() |
106.1 | 652 | |
![]() |
119.1 | 653 | * **RS422** |
![]() |
104.1 | 654 | |
![]() |
119.1 | 655 | [[image:image-20220825103350-4.png]] |
![]() |
104.1 | 656 | |
![]() |
119.1 | 657 | [[image:image-20220825100845-4.png]] |
![]() |
104.1 | 658 | |
659 | |||
![]() |
119.1 | 660 | == **FX3U,3G,3GA Serial Protocol** == |
![]() |
56.1 | 661 | |
![]() |
106.1 | 662 | Supported Series: Mitsubishi FX3U, FX3G, FX3GA series |
![]() |
56.1 | 663 | |
![]() |
119.1 | 664 | **1)V-BOX Settings** |
![]() |
106.1 | 665 | |
![]() |
119.1 | 666 | |**Item**|**Settings**|**Note** |
667 | |Protocol|Mitsubishi FX3U/3G/3GA| | ||
668 | |Connection|RS422/RS485/RS232| | ||
669 | |Baud rate|9600~~115200| | ||
670 | |Data bit|7/8| | ||
671 | |Parity|EVEN/Odd/None| | ||
672 | |Stop bit|1/2| | ||
673 | |PLC station No.|1~~255| | ||
![]() |
106.1 | 674 | |
![]() |
119.1 | 675 | **2)Address List** |
![]() |
106.1 | 676 | |
![]() |
119.1 | 677 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
678 | |(% rowspan="7" %)Bit|X|X|Xo|0~~303237| | ||
679 | |Y|Y|Y o|0~~303237| | ||
680 | |M|M|M d|0~~99999| | ||
681 | |T|T|T d|0~~99999| | ||
682 | |C|C|C d|0~~99999| | ||
683 | |S|S|S d|0~~99999| | ||
684 | |SM|SM|SM d|8000~~9999| | ||
685 | |(% rowspan="8" %)Word|X|X|Xo|0~~303237| | ||
686 | |Y|Y|Y o|0~~303237| | ||
687 | |M|M|M d|0~~99999| | ||
688 | |T|T|T d|0~~99999| | ||
689 | |C|C|C d|0~~199| | ||
690 | |D|D|D d|0~~7999| | ||
691 | |S|S|S d|0~~99999| | ||
692 | |SD|SD|SD d|8000~~9999| | ||
![]() |
106.1 | 693 | |
![]() |
119.1 | 694 | **3)Configure the communication protocol** |
![]() |
106.1 | 695 | |
![]() |
119.1 | 696 | [[image:image-20220825102649-2.png]] |
![]() |
106.1 | 697 | |
![]() |
119.1 | 698 | **4)Cable Wiring** |
![]() |
106.1 | 699 | |
![]() |
119.1 | 700 | * **RS422** |
![]() |
106.1 | 701 | |
![]() |
119.1 | 702 | [[image:image-20220825103421-5.png]] |
![]() |
106.1 | 703 | |
![]() |
119.1 | 704 | [[image:image-20220825100845-4.png]] |
![]() |
106.1 | 705 | |
706 | |||
![]() |
119.1 | 707 | == **FX5U Serial Protocol** == |
![]() |
103.1 | 708 | |
![]() |
107.1 | 709 | Mitsubishi FX5U series PLC |
![]() |
103.1 | 710 | |
![]() |
119.1 | 711 | **1)V-BOX Settings** |
![]() |
107.1 | 712 | |
![]() |
119.1 | 713 | |**Item**|**Settings**|**Note** |
714 | |Protocol|Mitsubishi FX5U| | ||
715 | |Connection|RS422/RS485| | ||
716 | |Baud rate|9600| | ||
717 | |Data bit|7| | ||
718 | |Parity|Odd| | ||
719 | |Stop bit|1| | ||
720 | |PLC station No.|1~~255|Need to be the same as PLC settings | ||
![]() |
107.1 | 721 | |
![]() |
119.1 | 722 | **2)Address List** |
![]() |
107.1 | 723 | |
![]() |
119.1 | 724 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
725 | |(% rowspan="15" %)Bit|X|X|X o|0~~303237| | ||
726 | |Y|Y|Y o|0~~303237| | ||
727 | |M|M|M d|0~~99999| | ||
728 | |B|B|B h|0~~7FFF| | ||
729 | |F|F|F d|0~~32767| | ||
730 | |SB|SB|SB h|0~~7FFF| | ||
731 | |TS|TS|TS d|0~~1023| | ||
732 | |TC|TC|TC d|0~~1023| | ||
733 | |STS|STS|STS d|0~~1023| | ||
734 | |STC|STC|STS d|0~~1023| | ||
735 | |CS|CS|CS d|0~~1023| | ||
736 | |CC|CC|CC d|0~~1023| | ||
737 | |SM|SM|SM d|0~~9999| | ||
738 | |L|L|L d|0~~32767| | ||
739 | |S|S|S d|0~~4095| | ||
740 | |(% rowspan="9" %)Word|W|W|W h|0~~3FF| | ||
741 | |TN|TN|TN d|0~~1023| | ||
742 | |STN|STN|STN d|0~~1023| | ||
743 | |CN|CN|CN d|0~~1023| | ||
744 | |R|R|R d|0~~32767| | ||
745 | |SW|SW|SW h|0~~7FFF| | ||
746 | |Z|Z|Z d|0~~23| | ||
747 | |D|D|D d|0~~7999| | ||
748 | |SD|SD|SD d|0~~11999| | ||
![]() |
107.1 | 749 | |
![]() |
119.1 | 750 | **3)PLC Settings (GX Works 3)** |
![]() |
107.1 | 751 | |
752 | Create a blank FX5U project | ||
753 | |||
754 | Find the 485 serial port module in the system navigation bar and double click to enter the settings. | ||
755 | |||
![]() |
119.1 | 756 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] |
![]() |
107.1 | 757 | |
758 | Select protocol in the setting item, and set parameters. | ||
759 | |||
![]() |
119.1 | 760 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] |
![]() |
107.1 | 761 | |
762 | Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) | ||
763 | |||
![]() |
119.1 | 764 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] |
![]() |
107.1 | 765 | |
766 | Click the [Apply] button to finish the setting. | ||
767 | |||
768 | Click download and select the items as below, then click [execute] to download the configuration to PLC. | ||
769 | |||
![]() |
119.1 | 770 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] |
![]() |
107.1 | 771 | |
772 | As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. | ||
773 | |||
774 | Done. | ||
775 | |||
![]() |
119.1 | 776 | **4)Configure the communication protocol** |
![]() |
107.1 | 777 | |
![]() |
119.1 | 778 | [[image:image-20220825104904-1.png]] |
![]() |
107.1 | 779 | |
![]() |
119.1 | 780 | **5)Cable Wiring** |
![]() |
107.1 | 781 | |
782 | |||
![]() |
119.1 | 783 | * **RS422** |
![]() |
107.1 | 784 | |
![]() |
119.1 | 785 | [[image:image-20220825105105-2.png]] |
![]() |
107.1 | 786 | |
![]() |
119.1 | 787 | [[image:image-20220825105533-3.png]] |
![]() |
107.1 | 788 | |
![]() |
119.1 | 789 | == **FX5U Ethernet Protocol** == |
![]() |
100.1 | 790 | |
791 | Mitsubishi FX5U series PLC | ||
792 | |||
![]() |
119.1 | 793 | **1)V-BOX Settings** |
![]() |
100.1 | 794 | |
![]() |
119.1 | 795 | |**Items**|**Settings**|**Note** |
796 | |Protocol|Mitsubishi FX5U| | ||
797 | |Connection|Ethernet| | ||
798 | |Port No.|5002|Must be the same as the PLC setting | ||
799 | |PLC station No.|0| | ||
![]() |
100.1 | 800 | |
![]() |
119.1 | 801 | **2)Address List** |
![]() |
100.1 | 802 | |
![]() |
119.1 | 803 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
804 | |(% rowspan="15" %)Bit|X|X|X o|0~~303237| | ||
805 | |Y|Y|Y o|0~~303237| | ||
806 | |M|M|M d|0~~99999| | ||
807 | |B|B|B h|0~~7FFF| | ||
808 | |F|F|F d|0~~32767| | ||
809 | |SB|SB|SB h|0~~7FFF| | ||
810 | |TS|TS|TS d|0~~1023| | ||
811 | |TC|TC|TC d|0~~1023| | ||
812 | |STS|STS|STS d|0~~1023| | ||
813 | |STC|STC|STS d|0~~1023| | ||
814 | |CS|CS|CS d|0~~1023| | ||
815 | |CC|CC|CC d|0~~1023| | ||
816 | |SM|SM|SM d|0~~9999| | ||
817 | |L|L|L d|0~~32767| | ||
818 | |S|S|S d|0~~4095| | ||
819 | |(% rowspan="9" %)Word|W|W|W h|0~~3FF| | ||
820 | |TN|TN|TN d|0~~1023| | ||
821 | |STN|STN|STN d|0~~1023| | ||
822 | |CN|CN|CN d|0~~1023| | ||
823 | |R|R|R d|0~~32767| | ||
824 | |SW|SW|SW h|0~~7FFF| | ||
825 | |Z|Z|Z d|0~~23| | ||
826 | |D|D|D d|0~~7999| | ||
827 | |SD|SD|SD d|0~~11999| | ||
![]() |
100.1 | 828 | |
![]() |
119.1 | 829 | **3)PLC Settings (GX Works 3)** |
![]() |
100.1 | 830 | |
831 | Find the [Ethernet port] in the navigation area. | ||
832 | |||
![]() |
119.1 | 833 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] |
![]() |
100.1 | 834 | |
835 | Select [Own Node Settings] in the [Setting Item List]; | ||
836 | |||
837 | Set [IP Address], [Subnet Mask], [Default Gateway]; | ||
838 | |||
839 | Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; | ||
840 | |||
![]() |
119.1 | 841 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] |
![]() |
100.1 | 842 | |
843 | Select [SLMP Connection Module] and add into host station as below picture shows; | ||
844 | |||
845 | Set Port number as 5002 (this is necessary settings); | ||
846 | |||
847 | Click [Close with Reflecting the Setting] to save and close window; | ||
848 | |||
![]() |
119.1 | 849 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] |
![]() |
100.1 | 850 | |
851 | Click [Apply] to completed Etherenet settings; | ||
852 | |||
853 | Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. | ||
854 | |||
![]() |
119.1 | 855 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] |
![]() |
100.1 | 856 | |
![]() |
119.1 | 857 | **4)Configure the communication protocol** |
![]() |
110.1 | 858 | |
![]() |
119.1 | 859 | [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] |
![]() |
110.1 | 860 | |
![]() |
119.1 | 861 | **5)电缆布线** |
![]() |
110.1 | 862 | |
![]() |
119.1 | 863 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] |
![]() |
113.1 | 864 | |
![]() |
122.1 | 865 | |
866 | == **L02 Serial Protocol** == | ||
867 | |||
![]() |
134.1 | 868 | Mitsubishi L02 series CPU built-in serial port. |
![]() |
122.1 | 869 | |
![]() |
135.1 | 870 | **1)V-BOX Settings** |
![]() |
122.1 | 871 | |
![]() |
134.1 | 872 | |**Item**|**Settings**|**Note** |
873 | |Protocol|Mitsubishi L02| | ||
874 | |Connection|RS422| | ||
875 | |Baud rate|115200| | ||
876 | |Data bit|8| | ||
877 | |Parity|Odd| | ||
878 | |Stop bit|1| | ||
879 | |PLC station No.|1~~255|Need to be the same as PLC settings | ||
![]() |
122.1 | 880 | |
![]() |
135.1 | 881 | **2)Address List** |
![]() |
122.1 | 882 | |
883 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
884 | |Bit|X|X|X h|0~~FFFF| | ||
885 | |Bit|Y|Y|Y h|0~~FFFF| | ||
886 | |Bit|M|M|M d|0~~9999| | ||
887 | |Bit|L|L|L d|0~~9999| | ||
888 | |Bit|F|F|F d|0~~9999| | ||
889 | |Bit|B|B|B h|0~~FFFF| | ||
890 | |Bit|V|V|V d|0~~2047| | ||
891 | |Bit|TC|TC|TC d|0~~9999| | ||
892 | |Bit|SS|SS|SS d|0~~9999| | ||
893 | |Bit|SC|SC|SC d|0~~9999| | ||
894 | |Bit|CS|CS|CS d|0~~9999| | ||
895 | |Bit|CC|CC|CC d|0~~9999| | ||
896 | |Bit|SB|SB|SB h|0~~FFFF| | ||
897 | |Bit|SM|SM|SM d|0~~2047| | ||
898 | |Bit|STS|STS|STS d|0~~1023| | ||
899 | |Bit|S|S|S d|0~~9999| | ||
900 | |Bit|DX|DX|DX h|0~~FFFF| | ||
901 | |Bit|DY|DY|DY h|0~~FFFF| | ||
902 | |Bit|TS|TS|TS d|0~~9999| | ||
903 | |Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| | ||
904 | |Word|W|W|W h|0~~FFFF| | ||
905 | |Word|TN|TN|TN d|0~~99999| | ||
906 | |Word|SN|SN|SN d|0~~99999| | ||
907 | |Word|CN|CN|CN d|0~~99999| | ||
908 | |Word|R|R|R d|0~~99999| | ||
909 | |Word|SW|SW|SW h|0~~FFFF| | ||
910 | |Word|Z|Z|Z d|0~~99999| | ||
911 | |Word|ZR|ZR|ZR h|0~~FFFF| | ||
912 | |Word|D|D|D d|0~~99999| | ||
913 | |||
![]() |
135.1 | 914 | **3)Communication Settings** |
![]() |
122.1 | 915 | |
![]() |
134.1 | 916 | [[image:image-20220825160648-3.png]] |
![]() |
122.1 | 917 | |
![]() |
135.1 | 918 | **4)Cable Wiring** |
![]() |
122.1 | 919 | |
![]() |
134.1 | 920 | * **RS422** |
![]() |
122.1 | 921 | |
![]() |
134.1 | 922 | [[image:image-20220825161612-8.png]] |
![]() |
122.1 | 923 | |
![]() |
134.1 | 924 | [[image:image-20220825160820-4.png]] |
![]() |
122.1 | 925 | |
![]() |
118.1 | 926 | == **L02 Ethernet Protocol** == |
![]() |
113.1 | 927 | |
![]() |
114.1 | 928 | Mitsubishi L series CPU built-in Ethernet port. |
![]() |
113.1 | 929 | |
![]() |
115.1 | 930 | **1)V-BOX Settings** |
![]() |
113.1 | 931 | |
932 | |**Items**|**Settings**|**Note** | ||
933 | |Protocol|MIT L02 CPU MELSEC| | ||
934 | |Connection|Ethernet| | ||
935 | |Port No.|1025|Must be the same as the PLC setting | ||
936 | |PLC station No.|0|Must be the same as the PLC setting | ||
937 | |||
![]() |
115.1 | 938 | **2)Address List** |
![]() |
113.1 | 939 | |
940 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
941 | |Bit|X|X|X h|0~~FFFF| | ||
942 | |Bit|Y|Y|Y h|0~~FFFF| | ||
943 | |Bit|M|M|M d|0~~9999| | ||
944 | |Bit|L|L|L d|0~~9999| | ||
945 | |Bit|F|F|F d|0~~9999| | ||
946 | |Bit|B|B|B h|0~~FFFF| | ||
947 | |Bit|V|V|V d|0~~2047| | ||
948 | |Bit|TC|TC|TC d|0~~9999| | ||
949 | |Bit|SS|SS|SS d|0~~9999| | ||
950 | |Bit|SC|SC|SC d|0~~9999| | ||
951 | |Bit|CS|CS|CS d|0~~9999| | ||
952 | |Bit|CC|CC|CC d|0~~9999| | ||
953 | |Bit|SB|SB|SB h|0~~FFFF| | ||
954 | |Bit|SM|SM|SM d|0~~2047| | ||
955 | |Bit|STS|STS|STS d|0~~1023| | ||
956 | |Bit|S|S|S d|0~~9999| | ||
957 | |Bit|DX|DX|DX h|0~~FFFF| | ||
958 | |Bit|DY|DY|DY h|0~~FFFF| | ||
959 | |Bit|TS|TS|TS d|0~~9999| | ||
960 | |Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| | ||
961 | |Word|W|W|W h|0~~FFFF| | ||
962 | |Word|TN|TN|TN d|0~~99999| | ||
963 | |Word|SN|SN|SN d|0~~99999| | ||
964 | |Word|CN|CN|CN d|0~~99999| | ||
965 | |Word|R|R|R d|0~~99999| | ||
966 | |Word|SW|SW|SW h|0~~FFFF| | ||
967 | |Word|Z|Z|Z d|0~~99999| | ||
968 | |Word|ZR|ZR|ZR h|0~~FFFF| | ||
969 | |Word|D|D|D d|0~~99999| | ||
970 | |||
![]() |
121.1 | 971 | **3)PLC Settings (GX Works2 )** |
![]() |
113.1 | 972 | |
973 | Create a project | ||
974 | |||
975 | Set PLC IP, subnet mask and gateway; | ||
976 | |||
977 | Select [Binary Code] as communication data code; | ||
978 | |||
979 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] | ||
980 | |||
981 | Set PLC port number, for example 1025 | ||
982 | |||
983 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] | ||
984 | |||
985 | Save settings; | ||
986 | |||
987 | Download project into PLC device; | ||
988 | |||
989 | Restart PLC device; | ||
990 | |||
![]() |
121.1 | 991 | **4)Configure the communication protocol** |
992 | |||
993 | [[image:image-20220825142659-1.png]] | ||
994 | |||
![]() |
115.1 | 995 | **5)Cable Wiring** |
![]() |
113.1 | 996 | |
![]() |
109.1 | 997 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] |
![]() |
100.1 | 998 | |
![]() |
119.1 | 999 | == **QJ71E71 Ethernet Protocol** == |
![]() |
1.1 | 1000 | |
![]() |
119.1 | 1001 | Mitsubishi QJ71E71 Ethernet communication module; |
![]() |
1.1 | 1002 | |
![]() |
120.1 | 1003 | **1)V-BOX Settings** |
![]() |
1.1 | 1004 | |
![]() |
119.1 | 1005 | |**Items**|**Settings**|**Note** |
1006 | |Protocol|MIT QJ71E71 MELSEC| | ||
1007 | |Connection|Ethernet| | ||
1008 | |Port No.|1025|Must be the same as the PLC setting | ||
1009 | |PLC station No.|0|Must be the same as the PLC setting | ||
![]() |
1.1 | 1010 | |
![]() |
120.1 | 1011 | **2)Address List** |
![]() |
48.1 | 1012 | |
![]() |
119.1 | 1013 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
1014 | |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| | ||
1015 | |Y|Y|Y h|0~~1FFF| | ||
1016 | |M|M|M d|0~~99999| | ||
1017 | |L|L|L d|0~~8191| | ||
1018 | |F|F|F d|0~~2047| | ||
1019 | |B|B|B h|0~~1FFF| | ||
1020 | |V|V|V d|0~~2047| | ||
1021 | |TS|TS|TS d|0~~2047| | ||
1022 | |TC|TC|TC d|0~~2047| | ||
1023 | |SS|SS|SS d|0~~2047| | ||
1024 | |SC|SC|SC d|0~~2047| | ||
1025 | |CS|CS|CS d|0~~1023| | ||
1026 | |CC|CC|CC d|0~~1023| | ||
1027 | |SB|SB|SB h|0~~7FF| | ||
1028 | |S|S|S d|0~~8191| | ||
1029 | |DX|DX|DX h|0~~1FFF| | ||
1030 | |DY|DY|DY h|0~~1FFF| | ||
1031 | |SM|SM|SM d|8000~~9999| | ||
1032 | |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| | ||
1033 | |D|D|D d|0~~12287| | ||
1034 | |W|W|W h|0~~1FFF| | ||
1035 | |TN|TN|TN d|0~~2047| | ||
1036 | |SN|SN|SN d|0~~2047| | ||
1037 | |CN|CN|CN d|0~~1023| | ||
1038 | |R|R|R d|0~~32767| | ||
1039 | |SW|SW|SW h|0~~7FF| | ||
1040 | |Z|Z|Z d|0~~15| | ||
1041 | |ZR|ZR|ZR h|0~~FE7FF| | ||
![]() |
7.1 | 1042 | |
![]() |
120.1 | 1043 | **3)PLC Settings(GX Works2)** |
![]() |
7.1 | 1044 | |
![]() |
119.1 | 1045 | * Click [Ethernet/CC IE/MELSECNET]; |
1046 | * Please select [Ethernet] as network type; | ||
1047 | * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); | ||
1048 | * Select [Online] as Mode; | ||
1049 | * Click [Operation setting] to set IP; | ||
1050 | * Select [Binary Code] as [Communication Data Code]; | ||
1051 | * Set protocol: TCP; | ||
1052 | * Set [unpassive] in [Open system]; | ||
1053 | * Set [receive] in [Fixed buffer]; | ||
1054 | * Set [procedure Exist] in [Fixed buffer communication]; | ||
1055 | * Disable [Pairing open]; | ||
1056 | * Set [No confirm] in [Existence confirmation]; | ||
1057 | * Host station port number: 1025; | ||
1058 | * Save settings; | ||
1059 | * Download project into PLC and restart it | ||
1060 | |||
![]() |
120.1 | 1061 | **4)Configure the communication protocol** |
![]() |
119.1 | 1062 | |
![]() |
120.1 | 1063 | [[image:image-20220825143728-1.png]] |
1064 | |||
1065 | **5)Cable Wiring** | ||
1066 | |||
![]() |
119.1 | 1067 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] |
1068 | |||
![]() |
138.1 | 1069 | = Create communication with **Delta PLC** = |
![]() |
119.1 | 1070 | |
![]() |
132.1 | 1071 | == **DVP Ethernet Protocol** == |
![]() |
131.1 | 1072 | |
![]() |
119.1 | 1073 | [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] |
1074 | |||
![]() |
127.1 | 1075 | == **DVP serial protocol** == |
![]() |
119.1 | 1076 | |
1077 | [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] | ||
1078 | |||
![]() |
142.1 | 1079 | == **AS Ethernet Protocol** == |
1080 | |||
1081 | **1)V-BOX Settings** | ||
1082 | |||
1083 | |=**Items**|=**Settings**|=**Note** | ||
1084 | |Protocol|DELTA AS300 MODBUS TCP| | ||
1085 | |Connection|Ethernet| | ||
1086 | |Port No.|502| | ||
1087 | |Device No.|1| | ||
1088 | |HMI No.|0| | ||
1089 | |||
1090 | **2)Address List** | ||
1091 | |||
1092 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
1093 | |Bit|X|X|X d|0~~63| | ||
1094 | |Bit|Y|Y|Y d|0~~63| | ||
1095 | |Bit|D|D|D d|0~~29999| | ||
1096 | |Bit|M|M|M d|0~~8191| | ||
1097 | |Bit|SM|SM|SM d|0~~4095| | ||
1098 | |Bit|S|S|S h|0~~2047| | ||
1099 | |Bit|T|T|T d|0~~511| | ||
1100 | |Bit|C|C|C d|0~~511| | ||
1101 | |Bit|HC|HC|HC d|0~~255| | ||
1102 | |Word|X|X|X h|0~~63| | ||
1103 | |Word|Y|Y|Y d|0~~63| | ||
1104 | |Word|SR|SR|SR d|0~~2047| | ||
1105 | |Word|D|D|D d|0~~29999| | ||
1106 | |Word|T|T|T d|0~~511| | ||
1107 | |Word|C|C|C h|0~~511| | ||
1108 | |Word|E|E|E d|0~~9| | ||
1109 | |||
1110 | **3)Configure the communication protocol** | ||
1111 | |||
1112 | |||
1113 | [[image:image-20220831160010-4.png]] | ||
1114 | |||
1115 | **4)Cable Wiring** | ||
1116 | |||
1117 | Figure | ||
1118 | |||
1119 | [[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] | ||
1120 | |||
1121 | Pin Definition Diagram | ||
1122 | |||
1123 | [[image:image-20220831155157-3.png]] | ||
1124 | |||
![]() |
138.1 | 1125 | = Create communication with **Omron PLC** = |
![]() |
119.1 | 1126 | |
![]() |
140.1 | 1127 | == **CP1 Series Protocol ** == |
![]() |
131.1 | 1128 | |
![]() |
119.1 | 1129 | [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] |
1130 | |||
![]() |
140.1 | 1131 | == **CP2M Series Protocol** == |
![]() |
119.1 | 1132 | |
1133 | [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] | ||
1134 | |||
![]() |
143.1 | 1135 | |
1136 | == **EC55 Protocol** == | ||
1137 | |||
1138 | Supported device: EC55 temperature instrument | ||
1139 | |||
1140 | **1)V-BOX Settings** | ||
1141 | |||
1142 | |**Items**|**Settings**|**Note** | ||
1143 | |Protocol|Omron EC55| | ||
1144 | |Connection|RS485 (9600, 2, 7, EVEN)| | ||
1145 | |Port No.|None| | ||
1146 | |PLC station No.|0| | ||
1147 | |||
1148 | **2)Address List** | ||
1149 | |||
1150 | |**Type**|**Register**|**Device range**|**HMI range**|**Function** | ||
1151 | |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 | ||
1152 | |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 | ||
1153 | |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 | ||
1154 | |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 | ||
1155 | |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 | ||
1156 | |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 | ||
1157 | |CP|-|0-6|Read controller intrinsic property | ||
1158 | |CS|-|0-2|Read controller states | ||
1159 | |CA|-|0-17|Action command | ||
1160 | |||
1161 | **3)Device Settings** | ||
1162 | |||
1163 | Omron E5CC PLC configuration | ||
1164 | |||
1165 | After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. | ||
1166 | |||
1167 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] | ||
1168 | |||
1169 | According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows | ||
1170 | |||
1171 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] | ||
1172 | |||
1173 | **✎Note:** The communication settings for HMI should be consistent with this setting. | ||
1174 | |||
1175 | **4)Configure the communication protocol** | ||
1176 | |||
1177 | [[image:image-20220831161041-1.png]] | ||
1178 | |||
1179 | **5)Cable Wiring** | ||
1180 | |||
1181 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] | ||
1182 | |||
1183 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] | ||
1184 | |||
1185 | **✎Note:** | ||
1186 | |||
1187 | * COM3 only available in PI8000/PI9000 series. | ||
1188 | * CA address could not support continuous writing function; | ||
1189 | * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid | ||
1190 | * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. | ||
1191 | * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. | ||
1192 | * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. | ||
1193 | * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. | ||
1194 | * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. | ||
1195 | * [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. | ||
1196 | |||
![]() |
138.1 | 1197 | = Create communication with **Modbus RTU** = |
![]() |
119.1 | 1198 | |
![]() |
131.1 | 1199 | == **V-BOX as Slave** == |
![]() |
119.1 | 1200 | |
![]() |
131.1 | 1201 | Select the protocol "Modbus RTU Slave (All Fuction)", |
![]() |
50.1 | 1202 | |
![]() |
131.1 | 1203 | Then set baud rate, port, stop bits, data bits, parity. |
![]() |
113.1 | 1204 | |
![]() |
50.1 | 1205 | (% style="text-align:center" %) |
![]() |
119.1 | 1206 | [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] |
![]() |
50.1 | 1207 | |
![]() |
131.1 | 1208 | == **V-BOX as Master** == |
![]() |
50.1 | 1209 | |
![]() |
131.1 | 1210 | Select the protocol "Modbus RTU Master", |
![]() |
50.1 | 1211 | |
![]() |
131.1 | 1212 | Then set baud rate, port, stop bits, data bits, parity |
![]() |
50.1 | 1213 | |
1214 | (% style="text-align:center" %) | ||
![]() |
119.1 | 1215 | [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] |
![]() |
50.1 | 1216 | |
![]() |
131.1 | 1217 | **address list** |
![]() |
50.1 | 1218 | |
1219 | (% class="table-bordered" %) | ||
![]() |
131.1 | 1220 | |**type**|**register**|**Function code and description** |
1221 | |(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) | ||
![]() |
119.1 | 1222 | |06 (write single register: write a binary value to a holding register) |
1223 | |10 (write values to multiple addresses ) | ||
1224 | |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) | ||
1225 | |06 (write single register: write a binary value to a holding register) | ||
1226 | |10 (write values to multiple addresses ) | ||
1227 | |(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) | ||
1228 | |06 (write single register: write a binary value to a holding register) | ||
1229 | |10 (write values to multiple addresses ) | ||
1230 | |(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) | ||
1231 | |10 (write values to multiple addresses ) | ||
1232 | |(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) | ||
1233 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
1234 | |0F (Write multiple bits, ie write continuously) | ||
1235 | |(% rowspan="3" %)1|02 (Read the input state) | ||
1236 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
1237 | |0F (Write multiple bits) | ||
1238 | |(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) | ||
1239 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
1240 | |0F (Write multiple bits) | ||
1241 | |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) | ||
1242 | |0F (Write multiple bits) | ||
![]() |
50.1 | 1243 | |
![]() |
119.1 | 1244 | == **communicate with VB inverter** == |
![]() |
52.1 | 1245 | |
![]() |
119.1 | 1246 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] |
![]() |
52.1 | 1247 | |
![]() |
119.1 | 1248 | = **User define protocol** = |
![]() |
1.1 | 1249 | |
![]() |
19.1 | 1250 | More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] |
![]() |
1.1 | 1251 | |
![]() |
119.1 | 1252 | == **Read the temperature sensor.** == |
![]() |
1.1 | 1253 | |
1254 | the commond format is as beliow: | ||
1255 | |||
1256 | Send commond:01 03 02 00 00 03 04 73 | ||
1257 | |||
1258 | Feedback commond:01 03 06 07 F7 0E 7E B7 35 | ||
1259 | |||
1260 | Temperature data:07 F7,desimal = 2039,it means temperature is 20.39℃. | ||
1261 | |||
1262 | Humidity data:0E 7E,desimal = 3710, it mean humidity is 37.10%RH. | ||
1263 | |||
1264 | Script Demo: | ||
1265 | |||
1266 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-- | ||
1267 | |||
1268 | function com.main() | ||
1269 | ~-~-dosomething | ||
1270 | openPlc() | ||
1271 | end | ||
1272 | function openPlc() | ||
1273 | if obj then | ||
1274 | ~-~- If the serial port opened,then read/write data by timing | ||
1275 | |||
1276 | local wri = string.pack(">HHHH",0X0103,0X0200,0X0003,0X0473) | ||
1277 | local arr = reading(wri) | ||
1278 | ~-~- if arr ~~=nil then | ||
1279 | ~-~- if arr[1] ==33 and arr[2] ==v[2][2] and arr[3] ==v[2][3] then | ||
1280 | ~-~- local A = arr[4]*256 | ||
1281 | ~-~- local B = A+arr[5] | ||
1282 | ~-~- addr_setword(v[1],B) | ||
1283 | ~-~- end | ||
1284 | ~-~- end | ||
1285 | |||
1286 | else | ||
1287 | ~-~-judge if there is a serial object, then initialize and open the serial port | ||
1288 | local configs = { | ||
1289 | name = 'COM1', ~-~-Select serial port COM1 | ||
1290 | mode = 485, ~-~-Communication mode RS485 | ||
1291 | baud_rate = 9600, ~-~-Baud rate 9600 | ||
1292 | stop_bit = 1, ~-~-stop bit 1 | ||
1293 | data_len = 8, ~-~-data length 8 | ||
1294 | check_bit = 'NONE', ~-~-no parity | ||
1295 | |||
1296 | } | ||
1297 | obj,err = serial.open(configs) ~-~-Open serial port | ||
1298 | if not obj then | ||
1299 | print("serial open :failed", err) ~-~- Open serial port failed | ||
1300 | end | ||
1301 | end | ||
1302 | end | ||
1303 | |||
1304 | function reading(wri) | ||
1305 | obj:flush() ~-~- Clear serial port | ||
1306 | obj:write(wri) ~-~- Write serial port | ||
1307 | print(string.byte(wri,1,#wri)) | ||
1308 | obj:flush() ~-~- Clear serial port | ||
1309 | local readed =obj:read(9,1000) ~-~- Read 9 bytes, timeout 1 second | ||
1310 | if readed and readed ~~= "" then | ||
1311 | ~-~- judge that a non-empty string is read | ||
1312 | print(string.byte(readed,1,#readed)) | ||
1313 | a={string.byte(readed, 1, #readed)} | ||
1314 | if nil ~~= a[4] and nil ~~= a[5] and nil ~~= a[6] and nil ~~= a[7] then | ||
1315 | a1=a[4]*256+a[5] | ||
1316 | a2=a[6]*256+a[7] | ||
1317 | addr_setword("@HDW0",a1) | ||
1318 | addr_setword("@HDW1",a2) | ||
1319 | end | ||
1320 | return {string.byte(readed, 1, #readed)} | ||
1321 | elseif readed == nil then | ||
1322 | print("serial read err:", err or "") | ||
1323 | return nil | ||
1324 | end | ||
1325 | return nil | ||
1326 | end | ||
1327 | |||
1328 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~- |