Wiki source code of 1 Communication
Version 76.1 by Ben on 2022/08/24 15:14
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = | ||
2 | |||
3 | == **LX3V Serial Protocol** == | ||
4 | |||
5 | Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM | ||
6 | |||
7 | **HMI Settings** | ||
8 | |||
9 | |**Item**|**Settings**|**Note** | ||
10 | |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| | ||
11 | |Connection|RS422/RS485| | ||
12 | |Baud rate|9600| | ||
13 | |Data bit|7| | ||
14 | |Parity|EVEN| | ||
15 | |Stop bit|1| | ||
16 | |PLC station No.|1| | ||
17 | |||
18 | **Address List** | ||
19 | |||
20 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
21 | |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| | ||
22 | |Y|Y|Y o|0~~303237| | ||
23 | |M|M|M d|0~~99999| | ||
24 | |T|T|T d|0~~99999| | ||
25 | |C|C|C d|0~~99999| | ||
26 | |S|S|S d|0~~99999| | ||
27 | |(% rowspan="8" %)Word|X|X|Xo|0~~303237| | ||
28 | |Y|Y|Y o|0~~303237| | ||
29 | |M|M|M d|0~~99999| | ||
30 | |T|T|T d|0~~99999| | ||
31 | |C|C|C d|0~~199| | ||
32 | |D|D|D d|0~~7999| | ||
33 | |S|S|S d|0~~99999| | ||
34 | |SD|SD|SD d|8000~~9999| | ||
35 | |||
36 | **Cable Wiring** | ||
37 | |||
38 | * **RS422** | ||
39 | |||
40 | [[image:image-20220824120614-5.png]] | ||
41 | |||
42 | * **RS485** | ||
43 | |||
44 | [[image:image-20220824120524-3.png]] | ||
45 | |||
46 | == **LX5V Serial Protocol** == | ||
47 | |||
48 | This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. | ||
49 | |||
50 | **Software configuration of PLC** | ||
51 | |||
52 | **1)PLC programming software** | ||
53 | |||
54 | [[image:image-20220824142722-1.png]] | ||
55 | |||
56 | **2)New PLC project** | ||
57 | |||
58 | Click New Project and select the PLC model. | ||
59 | |||
60 | [[image:image-20220822172623-2.png]] | ||
61 | |||
62 | **3)Set Serial port parameters** | ||
63 | |||
64 | Follow the steps below to configure Serial port parameters | ||
65 | |||
66 | Baud rate:115200 | ||
67 | |||
68 | Data bit:8 | ||
69 | |||
70 | Stop bit:1 | ||
71 | |||
72 | Parity:No verification | ||
73 | |||
74 | [[image:image-20220822172657-3.png]] | ||
75 | |||
76 | **4)Registers list** | ||
77 | |||
78 | [[image:image-20220822172730-4.png]] | ||
79 | |||
80 | **V-BOX software configuration** | ||
81 | |||
82 | **1)V-BOX programming software** | ||
83 | |||
84 | [[image:image-20220824104124-1.png]] | ||
85 | |||
86 | **2)V-NET add device** | ||
87 | |||
88 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. | ||
89 | |||
90 | [[image:image-20220824104909-2.png]] | ||
91 | |||
92 | |||
93 | **3)Set communication port parameters** | ||
94 | |||
95 | Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. | ||
96 | |||
97 | Baud rate:115200 | ||
98 | |||
99 | Data bit:8 | ||
100 | |||
101 | Stop bit:1 | ||
102 | |||
103 | Parity:No verification | ||
104 | |||
105 | [[image:image-20220824142130-1.png]] | ||
106 | |||
107 | **hardware connection** | ||
108 | |||
109 | **1)Hardware wiring diagram** | ||
110 | |||
111 | [[image:image-20220824142546-2.png]] | ||
112 | |||
113 | [[image:image-20220824142643-3.png]] | ||
114 | |||
115 | The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. | ||
116 | |||
117 | == **LX5V-N Ethernet protocol** == | ||
118 | |||
119 | This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. | ||
120 | |||
121 | **Software configuration of PLC** | ||
122 | |||
123 | **1)PLC programming software** | ||
124 | |||
125 | [[image:image-20220824142722-1.png]] | ||
126 | |||
127 | **2)New PLC project** | ||
128 | |||
129 | Click New Project and select the PLC model. | ||
130 | |||
131 | [[image:image-20220824143613-1.png]] | ||
132 | |||
133 | **3)Set Ethernet port parameters** | ||
134 | |||
135 | Follow the steps below to configure Ethernet parameters | ||
136 | |||
137 | PLC IP address:192.168.39.200 | ||
138 | |||
139 | default gateway:192.168.39.1 | ||
140 | |||
141 | subnet mask:255.255.255.0 | ||
142 | |||
143 | [[image:image-20220824143744-2.png]] | ||
144 | |||
145 | |||
146 | **4)Registers list** | ||
147 | |||
148 | [[image:image-20220822172730-4.png]] | ||
149 | |||
150 | (% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** | ||
151 | |||
152 | **1)V-BOX programming software** | ||
153 | |||
154 | [[image:image-20220824104124-1.png]] | ||
155 | |||
156 | **2)V-NET add device** | ||
157 | |||
158 | Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. | ||
159 | |||
160 | [[image:image-20220824104909-2.png]] | ||
161 | |||
162 | **3)Set communication port parameters** | ||
163 | |||
164 | |||
165 | Click Communication to configure the LX5V plc protocol and IP address. | ||
166 | |||
167 | [[image:image-20220824144619-1.png]] | ||
168 | |||
169 | **hardware connection** | ||
170 | |||
171 | **1)Hardware wiring diagram** | ||
172 | |||
173 | This example introduces V-BOX with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: | ||
174 | |||
175 | [[image:image-20220824151127-2.png]] | ||
176 | |||
177 | The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. | ||
178 | |||
179 | = **Rockwell PLC** = | ||
180 | |||
181 | == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == | ||
182 | |||
183 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 | ||
184 | |||
185 | **HMI Settings** | ||
186 | |||
187 | |**Item**|**Settings**|**Note** | ||
188 | |Protocol|Allen-Bradlley MicroLogix| | ||
189 | |Connection|RS232| | ||
190 | |Baud rate|19200| | ||
191 | |Data bit|8| | ||
192 | |Parity|None| | ||
193 | |Stop bit|1| | ||
194 | |PLC station No.|1| | ||
195 | |||
196 | **Address List** | ||
197 | |||
198 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
199 | |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| | ||
200 | |O|O d.d|0.0~~255.15| | ||
201 | |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
202 | |S|S d.d|0.0~~255.15| | ||
203 | |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
204 | |(% rowspan="9" %)Word|S|S d|0~~255| | ||
205 | |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) | ||
206 | |TP|TP nnhh|0~~ffff | ||
207 | |CS|CS nnhh|0~~ffff | ||
208 | |CP|CP nnhh|0~~ffff | ||
209 | |N|N nnhh|0~~ffff | ||
210 | |C|C nnhh|0~~ffff | ||
211 | |T|T nnhh|0~~ffff | ||
212 | |R|R nnhh|0~~ffff | ||
213 | |||
214 | **Cable Wiring** | ||
215 | |||
216 | [[image:image-20220824110724-1.png]] | ||
217 | |||
218 | |||
219 | |||
220 | == **CompactLogix Protocol** == | ||
221 | |||
222 | ((( | ||
223 | ((( | ||
224 | This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. | ||
225 | ))) | ||
226 | ))) | ||
227 | |||
228 | ((( | ||
229 | (% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) | ||
230 | ((( | ||
231 | **Software configuration of PLC** | ||
232 | ))) | ||
233 | |||
234 | (% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) | ||
235 | ((( | ||
236 | **1)PLC programming software** | ||
237 | ))) | ||
238 | |||
239 | [[image:image-20220714162600-1.png]] | ||
240 | |||
241 | (% class="wikigeneratedid" id="HNewPLCproject" %) | ||
242 | ((( | ||
243 | **2)New PLC project** | ||
244 | ))) | ||
245 | |||
246 | ((( | ||
247 | ((( | ||
248 | Click New Project and select the PLC model. | ||
249 | ))) | ||
250 | ))) | ||
251 | |||
252 | ((( | ||
253 | [[image:image-20220714162617-2.png]] | ||
254 | ))) | ||
255 | |||
256 | ((( | ||
257 | |||
258 | |||
259 | [[image:image-20220714162652-4.png]] | ||
260 | ))) | ||
261 | |||
262 | ((( | ||
263 | (% class="wikigeneratedid" id="HSetEthernetparameters" %) | ||
264 | ((( | ||
265 | **3)Set Ethernet parameters** | ||
266 | ))) | ||
267 | |||
268 | ((( | ||
269 | ((( | ||
270 | ((( | ||
271 | Follow the steps below to configure Ethernet parameters | ||
272 | ))) | ||
273 | ))) | ||
274 | ))) | ||
275 | |||
276 | ((( | ||
277 | ((( | ||
278 | ((( | ||
279 | PLC IP address:192.168.40.101 | ||
280 | ))) | ||
281 | ))) | ||
282 | ))) | ||
283 | |||
284 | ((( | ||
285 | ((( | ||
286 | ((( | ||
287 | default gateway:192.168.40.1 | ||
288 | ))) | ||
289 | ))) | ||
290 | ))) | ||
291 | |||
292 | ((( | ||
293 | ((( | ||
294 | ((( | ||
295 | subnet mask:255.255.255.0 | ||
296 | ))) | ||
297 | ))) | ||
298 | ))) | ||
299 | |||
300 | ((( | ||
301 | [[image:image-20220714162713-5.png]] | ||
302 | ))) | ||
303 | |||
304 | ((( | ||
305 | |||
306 | ))) | ||
307 | |||
308 | ((( | ||
309 | (% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) | ||
310 | ((( | ||
311 | **V-box software configuration** | ||
312 | ))) | ||
313 | |||
314 | (% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) | ||
315 | ((( | ||
316 | **1)V-box programming software** | ||
317 | ))) | ||
318 | |||
319 | (% class="wikigeneratedid" %) | ||
320 | ((( | ||
321 | [[image:image-20220714162725-6.png]] | ||
322 | ))) | ||
323 | |||
324 | (% class="wikigeneratedid" id="HConfiguredevicenetwork" %) | ||
325 | ((( | ||
326 | **2)Configure device network** | ||
327 | ))) | ||
328 | |||
329 | ((( | ||
330 | ((( | ||
331 | ((( | ||
332 | Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. | ||
333 | ))) | ||
334 | |||
335 | ((( | ||
336 | In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection | ||
337 | ))) | ||
338 | ))) | ||
339 | ))) | ||
340 | |||
341 | ((( | ||
342 | ((( | ||
343 | [[image:image-20220714162737-7.png]] | ||
344 | |||
345 | |||
346 | ))) | ||
347 | ))) | ||
348 | ))) | ||
349 | ))) | ||
350 | |||
351 | (% class="wikigeneratedid" id="HV-netadddevice" %) | ||
352 | ((( | ||
353 | **3)V-net add device** | ||
354 | ))) | ||
355 | ))) | ||
356 | |||
357 | ((( | ||
358 | ((( | ||
359 | Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] | ||
360 | ))) | ||
361 | |||
362 | |||
363 | ))) | ||
364 | |||
365 | ((( | ||
366 | (% class="wikigeneratedid" id="HSetcommunicationportparameters" %) | ||
367 | ((( | ||
368 | **4)Set communication port parameters** | ||
369 | ))) | ||
370 | |||
371 | ((( | ||
372 | In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. | ||
373 | ))) | ||
374 | |||
375 | [[image:image-20220714162805-9.png]] | ||
376 | ))) | ||
377 | |||
378 | ((( | ||
379 | The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. | ||
380 | ))) | ||
381 | |||
382 | [[image:image-20220714162814-10.png]] | ||
383 | |||
384 | |||
385 | ((( | ||
386 | After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] | ||
387 | ))) | ||
388 | |||
389 | (% class="wikigeneratedid" id="HEngineeringproduction" %) | ||
390 | ((( | ||
391 | **5)Engineering production** | ||
392 | ))) | ||
393 | |||
394 | (% class="wikigeneratedid" %) | ||
395 | ((( | ||
396 | ((( | ||
397 | According to your own needs, use the V-NET client software to edit the required data monitoring points. | ||
398 | ))) | ||
399 | |||
400 | [[image:image-20220714162841-12.png]] | ||
401 | |||
402 | |||
403 | ((( | ||
404 | **hardware connection** | ||
405 | ))) | ||
406 | ))) | ||
407 | |||
408 | ((( | ||
409 | **1)Hardware wiring diagram** | ||
410 | ))) | ||
411 | |||
412 | ((( | ||
413 | ((( | ||
414 | This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: | ||
415 | ))) | ||
416 | |||
417 | [[image:image-20220714162856-13.png]] | ||
418 | |||
419 | ((( | ||
420 | The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. | ||
421 | |||
422 | |||
423 | == **Allen-Bradley Ethernet DF1** == | ||
424 | |||
425 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] | ||
426 | |||
427 | |||
428 | = **Siemens PLC** = | ||
429 | |||
430 | == **S7-200 Smart Ethernet Protocol** == | ||
431 | |||
432 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] | ||
433 | ))) | ||
434 | ))) | ||
435 | |||
436 | == **S7-1200 Ethernet Protocol** == | ||
437 | |||
438 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] | ||
439 | |||
440 | = **Mitsubishi PLC** = | ||
441 | |||
442 | == **Mitsubishi FX Series Protocol** == | ||
443 | |||
444 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] | ||
445 | |||
446 | = **Delta PLC** = | ||
447 | |||
448 | == **DVP Ethernet Protocol** == | ||
449 | |||
450 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] | ||
451 | |||
452 | == **DVP Serial Protocol** == | ||
453 | |||
454 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] | ||
455 | |||
456 | = **Omron PLC** = | ||
457 | |||
458 | == **CP1 Series Protocol** == | ||
459 | |||
460 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] | ||
461 | |||
462 | == **CJ2M Series Protocol** == | ||
463 | |||
464 | [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] | ||
465 | |||
466 | = **Modbus RTU** = | ||
467 | |||
468 | == **V-BOX as master** == | ||
469 | |||
470 | Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, | ||
471 | |||
472 | (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity | ||
473 | |||
474 | (% style="text-align:center" %) | ||
475 | [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] | ||
476 | |||
477 | == **V-BOX as slave** == | ||
478 | |||
479 | Select the protocol “(% class="mark" %)**Modbus RTU Master”**, | ||
480 | |||
481 | (% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity | ||
482 | |||
483 | (% style="text-align:center" %) | ||
484 | [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] | ||
485 | |||
486 | **Address List** | ||
487 | |||
488 | (% class="table-bordered" %) | ||
489 | |**Type**|**Register**|**Function code & Description** | ||
490 | |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) | ||
491 | |06 (write single register: write a binary value to a holding register) | ||
492 | |10 (write values to multiple addresses ) | ||
493 | |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) | ||
494 | |06 (write single register: write a binary value to a holding register) | ||
495 | |10 (write values to multiple addresses ) | ||
496 | |(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) | ||
497 | |06 (write single register: write a binary value to a holding register) | ||
498 | |10 (write values to multiple addresses ) | ||
499 | |(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) | ||
500 | |10 (write values to multiple addresses ) | ||
501 | |(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) | ||
502 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
503 | |0F (Write multiple bits, ie write continuously) | ||
504 | |(% rowspan="3" %)1|02 (Read the input state) | ||
505 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
506 | |0F (Write multiple bits) | ||
507 | |(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) | ||
508 | |05 (Force a single coil to force the on/off state of a logic coil) | ||
509 | |0F (Write multiple bits) | ||
510 | |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) | ||
511 | |0F (Write multiple bits) | ||
512 | |||
513 | == **communicate with VB inverter** == | ||
514 | |||
515 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] | ||
516 | |||
517 | = **User define protocol** = | ||
518 | |||
519 | More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] | ||
520 | |||
521 | == **Read the temperature sensor.** == | ||
522 | |||
523 | the commond format is as beliow: | ||
524 | |||
525 | Send commond:01 03 02 00 00 03 04 73 | ||
526 | |||
527 | Feedback commond:01 03 06 07 F7 0E 7E B7 35 | ||
528 | |||
529 | Temperature data:07 F7,desimal = 2039,it means temperature is 20.39℃. | ||
530 | |||
531 | Humidity data:0E 7E,desimal = 3710, it mean humidity is 37.10%RH. | ||
532 | |||
533 | Script Demo: | ||
534 | |||
535 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-- | ||
536 | |||
537 | function com.main() | ||
538 | ~-~-dosomething | ||
539 | openPlc() | ||
540 | end | ||
541 | function openPlc() | ||
542 | if obj then | ||
543 | ~-~- If the serial port opened,then read/write data by timing | ||
544 | |||
545 | local wri = string.pack(">HHHH",0X0103,0X0200,0X0003,0X0473) | ||
546 | local arr = reading(wri) | ||
547 | ~-~- if arr ~~=nil then | ||
548 | ~-~- if arr[1] ==33 and arr[2] ==v[2][2] and arr[3] ==v[2][3] then | ||
549 | ~-~- local A = arr[4]*256 | ||
550 | ~-~- local B = A+arr[5] | ||
551 | ~-~- addr_setword(v[1],B) | ||
552 | ~-~- end | ||
553 | ~-~- end | ||
554 | |||
555 | else | ||
556 | ~-~-judge if there is a serial object, then initialize and open the serial port | ||
557 | local configs = { | ||
558 | name = 'COM1', ~-~-Select serial port COM1 | ||
559 | mode = 485, ~-~-Communication mode RS485 | ||
560 | baud_rate = 9600, ~-~-Baud rate 9600 | ||
561 | stop_bit = 1, ~-~-stop bit 1 | ||
562 | data_len = 8, ~-~-data length 8 | ||
563 | check_bit = 'NONE', ~-~-no parity | ||
564 | |||
565 | } | ||
566 | obj,err = serial.open(configs) ~-~-Open serial port | ||
567 | if not obj then | ||
568 | print("serial open :failed", err) ~-~- Open serial port failed | ||
569 | end | ||
570 | end | ||
571 | end | ||
572 | |||
573 | function reading(wri) | ||
574 | obj:flush() ~-~- Clear serial port | ||
575 | obj:write(wri) ~-~- Write serial port | ||
576 | print(string.byte(wri,1,#wri)) | ||
577 | obj:flush() ~-~- Clear serial port | ||
578 | local readed =obj:read(9,1000) ~-~- Read 9 bytes, timeout 1 second | ||
579 | if readed and readed ~~= "" then | ||
580 | ~-~- judge that a non-empty string is read | ||
581 | print(string.byte(readed,1,#readed)) | ||
582 | a={string.byte(readed, 1, #readed)} | ||
583 | if nil ~~= a[4] and nil ~~= a[5] and nil ~~= a[6] and nil ~~= a[7] then | ||
584 | a1=a[4]*256+a[5] | ||
585 | a2=a[6]*256+a[7] | ||
586 | addr_setword("@HDW0",a1) | ||
587 | addr_setword("@HDW1",a2) | ||
588 | end | ||
589 | return {string.byte(readed, 1, #readed)} | ||
590 | elseif readed == nil then | ||
591 | print("serial read err:", err or "") | ||
592 | return nil | ||
593 | end | ||
594 | return nil | ||
595 | end | ||
596 | |||
597 | ~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~-~- |