... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Mora - Content
-
... ... @@ -40,7 +40,7 @@ 40 40 41 41 F0.07=01 42 42 43 -6.On some equipment, two potentiometers are required to adjust the speed, one potentiometer 0-10V controls 20HZ, and the other potentiometer controls 0-10V control 25HZ so that the spindle frequency is superimposed, and the frequency is 45HZ. 43 +6. On some equipment, two potentiometers are required to adjust the speed, one potentiometer 0-10V controls 20HZ, and the other potentiometer controls 0-10V control 25HZ so that the spindle frequency is superimposed, and the frequency is 45HZ. 44 44 45 45 F0.03=2 46 46 ... ... @@ -66,7 +66,7 @@ 66 66 67 67 = **Acceleration time** = 68 68 69 -1 When the device is started, the customer feels that the startup time is too long or the startup time is too short, which parameters need to be modified? (This parameter should be fine-tuned appropriately according to the equipment load. Improper setting can easily cause fault alarms such as overcurrent). 69 +~1. When the device is started, the customer feels that the startup time is too long or the startup time is too short, which parameters need to be modified? (This parameter should be fine-tuned appropriately according to the equipment load. Improper setting can easily cause fault alarms such as overcurrent). 70 70 71 71 F0.18 (appropriate setting) etc. 72 72 ... ... @@ -238,7 +238,6 @@ 238 238 239 239 = **Digital input function** = 240 240 241 - 242 242 ~1. Since an external switch is needed on the device to control the emergency stop of the motor, which function parameter should be set? 243 243 244 244 F5.02=10 ... ... @@ -264,13 +264,11 @@ 264 264 265 265 = **Digital output function** = 266 266 267 - 268 268 ~1. The customer needs to use the FM open-collector output function. When the inverter fails, output a switch value to make the fault alarm lamp/fault buzzer act, so that the on-site operator knows that the inverter has a fault alarm and what to do Setup and wiring? 269 269 270 270 F6.00=1 271 271 272 272 F6.01=2 273 - 274 274 275 275 2. When the inverter runs more than 20HZ, the relay T1A and T1C terminals output a switch value to control an indicator light, so that the indicator line is connected and the indicator light is on. How to set up and wire? 276 276 ... ... @@ -304,12 +304,10 @@ 304 304 305 305 = **Display monitoring** = 306 306 307 - 308 308 ~1. Master the functions of F7.03, F7.04, and F7.05, all of which are used for display and monitoring. Please refer to page 35 of the manual for details 309 309 310 310 = **Operating mode selection** = 311 311 312 - 313 313 ~1. Master the definition of each control mode of the F0.00 parameter group. 314 314 315 315 Vector control, V/F control ... ... @@ -316,7 +316,6 @@ 316 316 317 317 = **Analog signal gain** = 318 318 319 - 320 320 ~1. The user uses the AI1 terminal function, and the device is given a voltage of 0-5V for speed regulation. Which parameter should be modified accordingly? 321 321 322 322 F0.03=2 ... ... @@ -350,7 +350,6 @@ 350 350 351 351 = **Display monitoring options** = 352 352 353 - 354 354 ~1. The user requires the inverter to display only the speed during operation, which parameter should be modified? 355 355 356 356 F7.03=4000 ... ... @@ -359,7 +359,6 @@ 359 359 2. The user requires the inverter to display various states during shutdown. Which parameter can be set? 360 360 361 361 F7.05 362 - 363 363 364 364 = **PID function** = 365 365 ... ... @@ -395,7 +395,6 @@ 395 395 396 396 = **Communication function** = 397 397 398 - 399 399 ~1. Familiar with RS485 communication function, communication address, communication speed, communication format, how to set it? Familiar with the address of communication function? 400 400 Please refer to page 129 of the manual 401 401 ... ... @@ -409,7 +409,6 @@ 409 409 410 410 = **Grounding** = 411 411 412 - 413 413 ~1. Understand the meaning and function of the ground wire and connect it correctly. 414 414 The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used. 415 415 ... ... @@ -439,7 +439,6 @@ 439 439 440 440 = **Braking resistor** = 441 441 442 - 443 443 ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? 444 444 445 445 Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) ... ... @@ -446,11 +446,8 @@ 446 446 447 447 = **Fault code and troubleshooting** = 448 448 449 - 450 450 ~1. Familiar with various fault codes and countermeasures to deal with faults. 451 451 452 452 = **Installation guidance required by EMC** = 453 453 454 454 The input terminal of the inverter has EMC screw access option. 455 - 456 -