Content
... ... @@ -297,7 +297,8 @@
297 297  
298 298  F6.02=1
299 299  
300 -= **Motor parameter setting and self-learning** =
300 +=
301 +**Motor parameter setting and self-learning** =
301 301  
302 302  ~1. Familiar with the motor self-learning function.
303 303  Need to input the motor parameters F2.01, F2.02, F2.03, F2.04, F2.05 to adjust the value of F2.11 to 1 (premise F0.01=0) or 2, press ENT first, Press RUN again, the self-learning is completed when the panel returns to the monitoring interface. (Necessary operation when changing to vector control)
... ... @@ -329,8 +329,10 @@
329 329  
330 330  F5.23=2
331 331  
332 -= **Parameter protection** =
333 +=
334 +**Parameter protection** =
333 333  
336 +
334 334  ~1. The protection parameters cannot be modified and the parameters are locked.
335 335  
336 336  F0.21=1
... ... @@ -339,8 +339,10 @@
339 339  
340 340  FE.00 = non-zero number
341 341  
342 -= **Set running time action** =
345 +=
346 +**Set running time action** =
343 343  
348 +
344 344  ~1. The customer sells the machine to the user, worrying that the customer did not pay on time, set some parameters inside the inverter. After the inverter has been running for 10 hours, the inverter will automatically stop and cannot start. Wait for the user to pay before the machine can run. How to set parameters for such a function?
345 345  FE.00=Set password
346 346  
... ... @@ -363,8 +363,6 @@
363 363  
364 364  = **PID function** =
365 365  
366 -(% style="text-align:center" %)
367 -[[image:生产流程图.png]]
368 368  
369 369  ~1. To be familiar with the PID function of constant pressure water supply, the feedback signal sources are remote pressure gauges and pressure transmitters. How to wire and which parameters should be set? For example, the maximum range of the remote pressure gauge is 1Mpa, and the current user needs to set the panel 0.45 MPa kg pressure, how to set the pressure?
370 370  F0.01=0 (panel start and stop)/1 (terminal start and stop)
... ... @@ -403,8 +403,10 @@
403 403  
404 404  Control operation command address: 2000H (premise F0.01=2)
405 405  
406 -= **Safety and precautions** =
409 +=
410 +**Safety and precautions** =
407 407  
412 +
408 408  ~1. Familiar with product standard technical specifications. Please refer to the manual
409 409  
410 410  = **Grounding** =
... ... @@ -413,8 +413,10 @@
413 413  ~1. Understand the meaning and function of the ground wire and connect it correctly.
414 414   The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used.
415 415  
416 -= **Peripheral lines** =
421 +=
422 +**Peripheral lines** =
417 417  
424 +
418 418  ~1. Understand the role of peripheral line equipment:
419 419  
420 420  Open
... ... @@ -433,11 +433,14 @@
433 433  
434 434  Braking resistor
435 435  
436 -= **Power and current value** =
443 +=
444 +**Power and current value** =
437 437  
446 +
438 438   ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual
439 439  
440 -= **Braking resistor** =
449 +=
450 +**Braking resistor** =
441 441  
442 442  
443 443   ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor?
... ... @@ -444,13 +444,16 @@
444 444  
445 445  Braking resistors are installed on the and PB ends of the inverter (built-in braking unit)
446 446  
447 -= **Fault code and troubleshooting** =
457 +=
458 +**Fault code and troubleshooting** =
448 448  
449 449  
450 450   ~1. Familiar with various fault codes and countermeasures to deal with faults.
451 451  
452 -= **Installation guidance required by EMC** =
463 +=
464 +**Installation guidance required by EMC** =
453 453  
466 +
454 454   The input terminal of the inverter has EMC screw access option.
455 455  
456 456  