Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 18.1
edited by Theodore Xu
on 2024/04/09 15:18
on 2024/04/09 15:18
Change comment:
There is no comment for this version
To version 24.1
edited by Theodore Xu
on 2024/04/22 11:04
on 2024/04/22 11:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -355,26 +355,27 @@ 355 355 356 356 = **Constant pressure water supply** = 357 357 358 - 359 -The following example uses a current transducer to simulate a water pressure test, the transducer specification is 4-20mA current signal, the range is 16 bar. use the transducer to connect to the AI2 terminal port of the VB. 360 -Please check the software version of F7.11 inverter first, if the software version is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 361 -F0.20=1 factory data reset 358 +The following example uses a current sensor to simulate a water pressure test, the sensor specification is 4-20mA current signal, the range is 16 bar. use the sensor to connect to the AI2 terminal port of the VB. 359 +Firstly please check the software version of **F7.11**, **F7.11 **is software version, if the **F7.11 **is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 360 +F0.20=1 Factory data reset 362 362 A4.00=1 363 -A4.01= set pressure362 +A4.01=Set pressure 364 364 A4.03=Sensor range 365 365 A4.04=0 366 366 367 367 If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 368 -F0.20=1 factory data reset367 +F0.20=1 Factory data reset 369 369 F0.03=8 370 370 F5.23=2 371 371 F9.01=Upper limit water pressure 372 372 F9.02=1 (AI2) 373 373 F9.28=1 374 -F9.29= Setpressure373 +F9.29=Target value 375 375 F9.31=Lower limit water pressure 376 -In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it needs to be greater than or equal to F9.29, it is recommended to set F9.29=F9.01 377 377 376 + 377 +In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it is recommended to set F9.29=F9.01,of course you can set F9.01=80%,it needs to be greater than or equal to F9.29. If when the control effect of the inverter is slow or the descent time is too long, try reducing the integration time: F9.06 = 0.5 or 1.0. 378 + 378 378 = **PID function** = 379 379 380 380 (% style="text-align:center" %) ... ... @@ -416,10 +416,6 @@ 416 416 417 417 Control operation command address: 2000H (premise F0.01=2) 418 418 419 -= **Safety and precautions** = 420 - 421 -~1. Familiar with product standard technical specifications. Please refer to the manual 422 - 423 423 = **Grounding** = 424 424 425 425 ~1. Understand the meaning and function of the ground wire and connect it correctly. ... ... @@ -445,20 +445,8 @@ 445 445 446 446 Braking resistor 447 447 448 -= **Power and current value** = 449 - 450 - ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 451 - 452 -= **Braking resistor** = 453 - 454 - ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? 455 - 456 -Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 457 - 458 -= **Fault code and troubleshooting** = 459 - 460 - ~1. Familiar with various fault codes and countermeasures to deal with faults. 461 - 462 462 = **Installation guidance required by EMC** = 463 463 464 464 The input terminal of the inverter has EMC screw access option. 448 + 449 +