Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 19.1
edited by Theodore Xu
on 2024/04/09 17:12
on 2024/04/09 17:12
Change comment:
There is no comment for this version
To version 29.1
edited by Theodore Xu
on 2024/04/23 09:27
on 2024/04/23 09:27
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -357,24 +357,24 @@ 357 357 358 358 The following example uses a current sensor to simulate a water pressure test, the sensor specification is 4-20mA current signal, the range is 16 bar. use the sensor to connect to the AI2 terminal port of the VB. 359 359 Firstly please check the software version of **F7.11**, **F7.11 **is software version, if the **F7.11 **is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 360 -F0.20=1 factory data reset360 +F0.20=1 Factory data reset 361 361 A4.00=1 362 -A4.01= set pressure362 +A4.01=Set pressure 363 363 A4.03=Sensor range 364 364 A4.04=0 365 365 366 366 If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 367 -F0.20=1 factory data reset367 +F0.20=1 Factory data reset 368 368 F0.03=8 369 369 F5.23=2 370 370 F9.01=Upper limit water pressure 371 371 F9.02=1 (AI2) 372 372 F9.28=1 373 -F9.29= Setpressure373 +F9.29=Target value 374 374 F9.31=Lower limit water pressure 375 375 376 376 377 -In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it needs to be greater than or equal to F9.29 ,it is recommended toset F9.29=F9.01377 +In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it is recommended to set F9.29=F9.01,of course you can set F9.01=80%,it needs to be greater than or equal to F9.29. If when the control effect of the inverter is slow or the descent time is too long, try reducing the integration time: F9.06 = 0.5 or 1.0. 378 378 379 379 = **PID function** = 380 380 ... ... @@ -417,10 +417,6 @@ 417 417 418 418 Control operation command address: 2000H (premise F0.01=2) 419 419 420 -= **Safety and precautions** = 421 - 422 -~1. Familiar with product standard technical specifications. Please refer to the manual 423 - 424 424 = **Grounding** = 425 425 426 426 ~1. Understand the meaning and function of the ground wire and connect it correctly. ... ... @@ -446,20 +446,78 @@ 446 446 447 447 Braking resistor 448 448 449 -= ** Powerandcurrentvalue** =445 += **Installation guidance required by EMC** = 450 450 451 - ~1.Familiar withthetedcurrentof the inverterindifferent powerranges, pleaserefer tohe manual447 + The input terminal of the inverter has EMC screw access option. 452 452 453 -= **Braking resistor**=449 += Torque mode control on winding project = 454 454 455 - ~1. Familiarwith theselection ofbrakingresistor.Underwhat conditionsdo you needtoinstallabrakingresistor?Howtoinstall thebrakingresistor?451 +Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 456 456 457 - Brakingresistors are installedon thend PB endsof the inverter (built-in braking unit)453 +Debugging ideas: 458 458 459 - =**Faultcode andtroubleshooting**=455 +~1. According to the application requirements of the torque command and the upper limit of the frequency. 460 460 461 - ~1.Familiarwithvariousfaultcodesandcountermeasures todealwith faults.457 +2. Set the frequency acceleration/deceleration time F0.18/F0.19 and the torque acceleration/deceleration time F3.14/F3.15, the torque acceleration/deceleration time is less than or equal to the frequency acceleration/deceleration time. 462 462 463 - =**Installationguidance required byEMC**=459 +3. Start the motor and observe whether the motor can run or not, if it can't run normally, rotate the motor with external force, if it can be started, it is judged to be necessary to increase the static friction coefficient compensation. 464 464 465 - The input terminal of the inverter has EMC screw access option. 461 +4. After the motor is running, observe the motor running state, if the motor is blocked, check whether it is shaking when it is blocked, if it is shaking, increase F3.07, generally 0.01 amplitude increment. 462 + 463 +5. When the torque command F3.10 is lower than the percentage of "no-load current / rated current", the running frequency is about: rated frequency * torque command percentage * rated current / no-load current. 464 + 465 +6. Static Friction Compensation Logic: During startup, the torque command 1 = F3.11* F3.24 /100 is passed to the performance; after a maintenance time of F3.25 seconds, it reverts to torque command 2 = F3.11; the switching of torque commands 1 /2 occurs through the torque acceleration and deceleration times F3.14 / F3.15; 466 + 467 +7. Auxiliary debugging parameters: filter coefficient F3.07 and static friction compensation F3.24/ F3.25. 468 + 469 +F0.00=0 Vector control 470 + 471 +F0.18=2.0 Acceleration time 472 + 473 +F0.19=2.0 Deceleration time 474 + 475 +F2.01=Motor rated power 476 + 477 +F2.02=Motor rated voltage 478 + 479 +F2.03=Rated motor current 480 + 481 +F2.04=Rated motor frequency 482 + 483 +F2.05=Rated motor speed 484 + 485 +F2.11=1 Static tuning 486 + 487 +F3.01=0.2 Speed loop integration time 488 + 489 +F3.07=0.005 Speed loop filter coefficient 490 + 491 +F3.09=1 Torque control 492 + 493 +F3.10=1 Torque control upper limit source 494 + 495 +F3.11=200 Torque upper limit setting 496 + 497 +F3.12=50 Torque control maximum frequency 498 + 499 +F3.14=1.2 Torque control acceleration time 500 + 501 +F3.15=1.2 Torque control deceleration time 502 + 503 +F3.16=120 Torque stiffness factor 504 + 505 +Torque control commissioning instructions: 506 + 507 +F0.18: Frequency acceleration time 508 + 509 +F0.19: Frequency deceleration time 510 + 511 +F3.14: Torque acceleration time 512 + 513 +F3.15: Torque deceleration time 514 + 515 +F3.07: Frequency low-pass filtering factor 516 + 517 +F3.24: Static friction compensation 518 + 519 +F3.25: Static friction compensation time