Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 2.1
edited by Leo Wei
on 2022/06/08 14:53
on 2022/06/08 14:53
Change comment:
Renamed from xwiki:3\. Demo.Common function of VB .WebHome
To version 19.1
edited by Theodore Xu
on 2024/04/09 17:12
on 2024/04/09 17:12
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Common function of VB 1 +4 Common function of VB - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - 3\.Demo.WebHome1 +VFD.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -40,7 +40,7 @@ 40 40 41 41 F0.07=01 42 42 43 -6.On some equipment, two potentiometers are required to adjust the speed, one potentiometer 0-10V controls 20HZ, and the other potentiometer controls 0-10V control 25HZ so that the spindle frequency is superimposed, and the frequency is 45HZ. 43 +6. On some equipment, two potentiometers are required to adjust the speed, one potentiometer 0-10V controls 20HZ, and the other potentiometer controls 0-10V control 25HZ so that the spindle frequency is superimposed, and the frequency is 45HZ. 44 44 45 45 F0.03=2 46 46 ... ... @@ -66,7 +66,7 @@ 66 66 67 67 = **Acceleration time** = 68 68 69 -1 When the device is started, the customer feels that the startup time is too long or the startup time is too short, which parameters need to be modified? (This parameter should be fine-tuned appropriately according to the equipment load. Improper setting can easily cause fault alarms such as overcurrent). 69 +~1. When the device is started, the customer feels that the startup time is too long or the startup time is too short, which parameters need to be modified? (This parameter should be fine-tuned appropriately according to the equipment load. Improper setting can easily cause fault alarms such as overcurrent). 70 70 71 71 F0.18 (appropriate setting) etc. 72 72 ... ... @@ -238,7 +238,6 @@ 238 238 239 239 = **Digital input function** = 240 240 241 - 242 242 ~1. Since an external switch is needed on the device to control the emergency stop of the motor, which function parameter should be set? 243 243 244 244 F5.02=10 ... ... @@ -264,13 +264,11 @@ 264 264 265 265 = **Digital output function** = 266 266 267 - 268 268 ~1. The customer needs to use the FM open-collector output function. When the inverter fails, output a switch value to make the fault alarm lamp/fault buzzer act, so that the on-site operator knows that the inverter has a fault alarm and what to do Setup and wiring? 269 269 270 270 F6.00=1 271 271 272 272 F6.01=2 273 - 274 274 275 275 2. When the inverter runs more than 20HZ, the relay T1A and T1C terminals output a switch value to control an indicator light, so that the indicator line is connected and the indicator light is on. How to set up and wire? 276 276 ... ... @@ -297,8 +297,7 @@ 297 297 298 298 F6.02=1 299 299 300 -= 301 -**Motor parameter setting and self-learning** = 297 += **Motor parameter setting and self-learning** = 302 302 303 303 ~1. Familiar with the motor self-learning function. 304 304 Need to input the motor parameters F2.01, F2.02, F2.03, F2.04, F2.05 to adjust the value of F2.11 to 1 (premise F0.01=0) or 2, press ENT first, Press RUN again, the self-learning is completed when the panel returns to the monitoring interface. (Necessary operation when changing to vector control) ... ... @@ -305,12 +305,10 @@ 305 305 306 306 = **Display monitoring** = 307 307 308 - 309 309 ~1. Master the functions of F7.03, F7.04, and F7.05, all of which are used for display and monitoring. Please refer to page 35 of the manual for details 310 310 311 311 = **Operating mode selection** = 312 312 313 - 314 314 ~1. Master the definition of each control mode of the F0.00 parameter group. 315 315 316 316 Vector control, V/F control ... ... @@ -317,7 +317,6 @@ 317 317 318 318 = **Analog signal gain** = 319 319 320 - 321 321 ~1. The user uses the AI1 terminal function, and the device is given a voltage of 0-5V for speed regulation. Which parameter should be modified accordingly? 322 322 323 323 F0.03=2 ... ... @@ -330,10 +330,8 @@ 330 330 331 331 F5.23=2 332 332 333 -= 334 -**Parameter protection** = 326 += **Parameter protection** = 335 335 336 - 337 337 ~1. The protection parameters cannot be modified and the parameters are locked. 338 338 339 339 F0.21=1 ... ... @@ -342,10 +342,8 @@ 342 342 343 343 FE.00 = non-zero number 344 344 345 -= 346 -**Set running time action** = 336 += **Set running time action** = 347 347 348 - 349 349 ~1. The customer sells the machine to the user, worrying that the customer did not pay on time, set some parameters inside the inverter. After the inverter has been running for 10 hours, the inverter will automatically stop and cannot start. Wait for the user to pay before the machine can run. How to set parameters for such a function? 350 350 FE.00=Set password 351 351 ... ... @@ -355,7 +355,6 @@ 355 355 356 356 = **Display monitoring options** = 357 357 358 - 359 359 ~1. The user requires the inverter to display only the speed during operation, which parameter should be modified? 360 360 361 361 F7.03=4000 ... ... @@ -364,10 +364,34 @@ 364 364 2. The user requires the inverter to display various states during shutdown. Which parameter can be set? 365 365 366 366 F7.05 367 - 368 368 356 += **Constant pressure water supply** = 357 + 358 +The following example uses a current sensor to simulate a water pressure test, the sensor specification is 4-20mA current signal, the range is 16 bar. use the sensor to connect to the AI2 terminal port of the VB. 359 +Firstly please check the software version of **F7.11**, **F7.11 **is software version, if the **F7.11 **is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 360 +F0.20=1 factory data reset 361 +A4.00=1 362 +A4.01=set pressure 363 +A4.03=Sensor range 364 +A4.04=0 365 + 366 +If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 367 +F0.20=1 factory data reset 368 +F0.03=8 369 +F5.23=2 370 +F9.01=Upper limit water pressure 371 +F9.02=1 (AI2) 372 +F9.28=1 373 +F9.29=Set pressure 374 +F9.31=Lower limit water pressure 375 + 376 + 377 +In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it needs to be greater than or equal to F9.29, it is recommended to set F9.29=F9.01 378 + 369 369 = **PID function** = 370 370 381 +(% style="text-align:center" %) 382 +[[image:生产流程图.png]] 371 371 372 372 ~1. To be familiar with the PID function of constant pressure water supply, the feedback signal sources are remote pressure gauges and pressure transmitters. How to wire and which parameters should be set? For example, the maximum range of the remote pressure gauge is 1Mpa, and the current user needs to set the panel 0.45 MPa kg pressure, how to set the pressure? 373 373 F0.01=0 (panel start and stop)/1 (terminal start and stop) ... ... @@ -398,7 +398,6 @@ 398 398 399 399 = **Communication function** = 400 400 401 - 402 402 ~1. Familiar with RS485 communication function, communication address, communication speed, communication format, how to set it? Familiar with the address of communication function? 403 403 Please refer to page 129 of the manual 404 404 ... ... @@ -406,22 +406,17 @@ 406 406 407 407 Control operation command address: 2000H (premise F0.01=2) 408 408 409 -= 410 -**Safety and precautions** = 420 += **Safety and precautions** = 411 411 412 - 413 413 ~1. Familiar with product standard technical specifications. Please refer to the manual 414 414 415 415 = **Grounding** = 416 416 417 - 418 418 ~1. Understand the meaning and function of the ground wire and connect it correctly. 419 419 The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used. 420 420 421 -= 422 -**Peripheral lines** = 429 += **Peripheral lines** = 423 423 424 - 425 425 ~1. Understand the role of peripheral line equipment: 426 426 427 427 Open ... ... @@ -440,30 +440,20 @@ 440 440 441 441 Braking resistor 442 442 443 -= 444 -**Power and current value** = 449 += **Power and current value** = 445 445 446 - 447 447 ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 448 448 449 -= 450 -**Braking resistor** = 453 += **Braking resistor** = 451 451 452 - 453 453 ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? 454 454 455 455 Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 456 456 457 -= 458 -**Fault code and troubleshooting** = 459 += **Fault code and troubleshooting** = 459 459 460 - 461 461 ~1. Familiar with various fault codes and countermeasures to deal with faults. 462 462 463 -= 464 -**Installation guidance required by EMC** = 463 += **Installation guidance required by EMC** = 465 465 466 - 467 467 The input terminal of the inverter has EMC screw access option. 468 - 469 -
- PID原理图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.5 KB - Content
- 生产流程图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.0 MB - Content