... ... @@ -1,1 +1,1 @@ 1 -VFD. 3\. Demo.WebHome1 +VFD.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Stone - Content
-
... ... @@ -297,8 +297,7 @@ 297 297 298 298 F6.02=1 299 299 300 -= 301 -**Motor parameter setting and self-learning** = 300 += **Motor parameter setting and self-learning** = 302 302 303 303 ~1. Familiar with the motor self-learning function. 304 304 Need to input the motor parameters F2.01, F2.02, F2.03, F2.04, F2.05 to adjust the value of F2.11 to 1 (premise F0.01=0) or 2, press ENT first, Press RUN again, the self-learning is completed when the panel returns to the monitoring interface. (Necessary operation when changing to vector control) ... ... @@ -330,10 +330,8 @@ 330 330 331 331 F5.23=2 332 332 333 -= 334 -**Parameter protection** = 332 += **Parameter protection** = 335 335 336 - 337 337 ~1. The protection parameters cannot be modified and the parameters are locked. 338 338 339 339 F0.21=1 ... ... @@ -342,10 +342,8 @@ 342 342 343 343 FE.00 = non-zero number 344 344 345 -= 346 -**Set running time action** = 342 += **Set running time action** = 347 347 348 - 349 349 ~1. The customer sells the machine to the user, worrying that the customer did not pay on time, set some parameters inside the inverter. After the inverter has been running for 10 hours, the inverter will automatically stop and cannot start. Wait for the user to pay before the machine can run. How to set parameters for such a function? 350 350 FE.00=Set password 351 351 ... ... @@ -406,10 +406,8 @@ 406 406 407 407 Control operation command address: 2000H (premise F0.01=2) 408 408 409 -= 410 -**Safety and precautions** = 404 += **Safety and precautions** = 411 411 412 - 413 413 ~1. Familiar with product standard technical specifications. Please refer to the manual 414 414 415 415 = **Grounding** = ... ... @@ -418,10 +418,8 @@ 418 418 ~1. Understand the meaning and function of the ground wire and connect it correctly. 419 419 The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used. 420 420 421 -= 422 -**Peripheral lines** = 414 += **Peripheral lines** = 423 423 424 - 425 425 ~1. Understand the role of peripheral line equipment: 426 426 427 427 Open ... ... @@ -440,14 +440,11 @@ 440 440 441 441 Braking resistor 442 442 443 -= 444 -**Power and current value** = 434 += **Power and current value** = 445 445 446 - 447 447 ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 448 448 449 -= 450 -**Braking resistor** = 438 += **Braking resistor** = 451 451 452 452 453 453 ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? ... ... @@ -454,16 +454,13 @@ 454 454 455 455 Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 456 456 457 -= 458 -**Fault code and troubleshooting** = 445 += **Fault code and troubleshooting** = 459 459 460 460 461 461 ~1. Familiar with various fault codes and countermeasures to deal with faults. 462 462 463 -= 464 -**Installation guidance required by EMC** = 450 += **Installation guidance required by EMC** = 465 465 466 - 467 467 The input terminal of the inverter has EMC screw access option. 468 468 469 469