Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -357,14 +357,14 @@ 357 357 358 358 The following example uses a current sensor to simulate a water pressure test, the sensor specification is 4-20mA current signal, the range is 16 bar. use the sensor to connect to the AI2 terminal port of the VB. 359 359 Firstly please check the software version of **F7.11**, **F7.11 **is software version, if the **F7.11 **is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 360 -F0.20=1 factory data reset360 +F0.20=1 Factory data reset 361 361 A4.00=1 362 -A4.01= set pressure362 +A4.01=Set pressure 363 363 A4.03=Sensor range 364 364 A4.04=0 365 365 366 366 If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 367 -F0.20=1 factory data reset367 +F0.20=1 Factory data reset 368 368 F0.03=8 369 369 F5.23=2 370 370 F9.01=Upper limit water pressure ... ... @@ -374,7 +374,7 @@ 374 374 F9.31=Lower limit water pressure 375 375 376 376 377 -In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it is recommended to set F9.29=F9.01,of course you can set F9.01=80%,it needs to be greater than or equal to F9.29. 377 +In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it is recommended to set F9.29=F9.01,of course you can set F9.01=80%,it needs to be greater than or equal to F9.29. If when the control effect of the inverter is slow or the descent time is too long, try reducing the integration time: F9.06 = 0.5 or 1.0. 378 378 379 379 = **PID function** = 380 380