Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 24.1
edited by Theodore Xu
on 2024/04/22 11:04
on 2024/04/22 11:04
Change comment:
There is no comment for this version
To version 25.1
edited by Theodore Xu
on 2024/04/22 13:48
on 2024/04/22 13:48
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -446,4 +446,74 @@ 446 446 447 447 The input terminal of the inverter has EMC screw access option. 448 448 449 - 449 += Torque mode control winding project = 450 + 451 +Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 452 + 453 +Debugging ideas: 454 + 455 +~1. According to the application requirements of the torque command and the upper limit of the frequency. 2. 456 + 457 +2. Set the frequency acceleration/deceleration time F0.18/F0.19 and the torque acceleration/deceleration time F3.14/F3.15, the torque acceleration/deceleration time is less than or equal to the frequency acceleration/deceleration time. 458 + 459 +3. Start the motor and observe whether the motor can run or not, if it can't run normally, rotate the motor with external force, if it can be started, it is judged to be necessary to increase the static friction coefficient compensation. 460 + 461 +4. After the motor is running, observe the motor running state, if the motor is blocked, check whether it is shaking when it is blocked, if it is shaking, increase F3.07, generally 0.01 amplitude increment. 462 + 463 +5. When the torque command F3.10 is lower than the percentage of "no-load current / rated current", the running frequency is about: rated frequency * torque command percentage * rated current / no-load current. 464 + 465 +6. Static Friction Compensation Logic: During startup, the torque command 1 = F3.11* F3.24 /100 is passed to the performance; after a maintenance time of F3.25 seconds, it reverts to torque command 2 = F3.11; the switching of torque commands 1 /2 occurs through the torque acceleration and deceleration times F3.14 / F3.15; 466 + 467 +7. Auxiliary debugging parameters: filter coefficient F3.07 and static friction compensation F3.24/ F3.25. 468 + 469 +F0.00=0;Vector control 470 + 471 +F0.18=2.0 acceleration time 472 + 473 +F0.19=2.0 deceleration time 474 + 475 +F2.01=motor rated power 476 + 477 +F2.02=Motor rated voltage 478 + 479 +F2.03=Rated motor current 480 + 481 +F2.04=Rated motor frequency 482 + 483 +F2.05=Rated motor speed 484 + 485 +F2.11=1 static tuning 486 + 487 +F3.01=0.2 speed loop integration time 488 + 489 +F3.07=0.005 speed loop filter coefficient 490 + 491 +F3.09=1 torque control 492 + 493 +F3.10=1 torque control upper limit source 494 + 495 +F3.11=200 torque upper limit setting 496 + 497 +F3.12=50 torque control maximum frequency 498 + 499 +F3.14=1.2 torque control acceleration time 500 + 501 +F3.15=1.2 torque control deceleration time 502 + 503 +F3.16 = 120 torque stiffness factor 504 + 505 +Torque control commissioning instructions: 506 + 507 +F0.18: frequency acceleration time 508 + 509 +F0.19: frequency deceleration time 510 + 511 +F3.14: torque acceleration time 512 + 513 +F3.15: torque deceleration time 514 + 515 +F3.07: frequency low-pass filtering factor 516 + 517 +F3.24: static friction compensation 518 + 519 +F3.25: static friction compensation time