... ... @@ -442,17 +442,22 @@
442 442  
443 443  Braking resistor
444 444  
445 -= **Installation guidance required by EMC** =
445 += **EMC** =
446 446  
447 - The input terminal of the inverter has EMC screw access option.
447 + The input terminal of the inverter has EMC screw access option. This screw can be removed when the input power supply encounters electromagnetic interference, and in most cases does not need to be removed.
448 448  
449 -= Torque mode control winding project =
449 +(% style="text-align:center" %)
450 +[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
450 450  
452 +
453 +
454 += Torque mode control on winding project =
455 +
451 451  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
452 452  
453 453  Debugging ideas:
454 454  
455 -~1. According to the application requirements of the torque command and the upper limit of the frequency. 2.
460 +~1. According to the application requirements of the torque command and the upper limit of the frequency.
456 456  
457 457  2. Set the frequency acceleration/deceleration time F0.18/F0.19 and the torque acceleration/deceleration time F3.14/F3.15, the torque acceleration/deceleration time is less than or equal to the frequency acceleration/deceleration time.
458 458  
... ... @@ -466,13 +466,13 @@
466 466  
467 467  7. Auxiliary debugging parameters: filter coefficient F3.07 and static friction compensation F3.24/ F3.25.
468 468  
469 -F0.00=0;Vector control
474 +F0.00=0 Vector control
470 470  
471 -F0.18=2.0 acceleration time
476 +F0.18=2.0 Acceleration time
472 472  
473 -F0.19=2.0 deceleration time
478 +F0.19=2.0 Deceleration time
474 474  
475 -F2.01=motor rated power
480 +F2.01=Motor rated power
476 476  
477 477  F2.02=Motor rated voltage
478 478  
... ... @@ -482,38 +482,38 @@
482 482  
483 483  F2.05=Rated motor speed
484 484  
485 -F2.11=1 static tuning
490 +F2.11=1 Static tuning
486 486  
487 -F3.01=0.2 speed loop integration time
492 +F3.01=0.2 Speed loop integration time
488 488  
489 -F3.07=0.005 speed loop filter coefficient
494 +F3.07=0.005 Speed loop filter coefficient
490 490  
491 -F3.09=1 torque control
496 +F3.09=1 Torque control
492 492  
493 -F3.10=1 torque control upper limit source
498 +F3.10=1 Torque control upper limit source
494 494  
495 -F3.11=200 torque upper limit setting
500 +F3.11=200 Torque upper limit setting
496 496  
497 -F3.12=50 torque control maximum frequency
502 +F3.12=50 Torque control maximum frequency
498 498  
499 -F3.14=1.2 torque control acceleration time
504 +F3.14=1.2 Torque control acceleration time
500 500  
501 -F3.15=1.2 torque control deceleration time
506 +F3.15=1.2 Torque control deceleration time
502 502  
503 -F3.16 = 120 torque stiffness factor
508 +F3.16=120 Torque stiffness factor
504 504  
505 505  Torque control commissioning instructions:
506 506  
507 -F0.18: frequency acceleration time
512 +F0.18: Frequency acceleration time
508 508  
509 -F0.19: frequency deceleration time
514 +F0.19: Frequency deceleration time
510 510  
511 -F3.14: torque acceleration time
516 +F3.14: Torque acceleration time
512 512  
513 -F3.15: torque deceleration time
518 +F3.15: Torque deceleration time
514 514  
515 -F3.07: frequency low-pass filtering factor
520 +F3.07: Frequency low-pass filtering factor
516 516  
517 -F3.24: static friction compensation
522 +F3.24: Static friction compensation
518 518  
519 -F3.25: static friction compensation time
524 +F3.25: Static friction compensation time
企业微信截图_16890580824807.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +423.4 KB
Content