... ... @@ -446,7 +446,7 @@
446 446  
447 447   The input terminal of the inverter has EMC screw access option.
448 448  
449 -= Torque mode control winding project =
449 += Torque mode control on winding project =
450 450  
451 451  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
452 452  
... ... @@ -468,11 +468,11 @@
468 468  
469 469  F0.00=0 Vector control
470 470  
471 -F0.18=2.0 acceleration time
471 +F0.18=2.0 Acceleration time
472 472  
473 -F0.19=2.0 deceleration time
473 +F0.19=2.0 Deceleration time
474 474  
475 -F2.01=motor rated power
475 +F2.01=Motor rated power
476 476  
477 477  F2.02=Motor rated voltage
478 478  
... ... @@ -482,38 +482,38 @@
482 482  
483 483  F2.05=Rated motor speed
484 484  
485 -F2.11=1 static tuning
485 +F2.11=1 Static tuning
486 486  
487 -F3.01=0.2 speed loop integration time
487 +F3.01=0.2 Speed loop integration time
488 488  
489 -F3.07=0.005 speed loop filter coefficient
489 +F3.07=0.005 Speed loop filter coefficient
490 490  
491 -F3.09=1 torque control
491 +F3.09=1 Torque control
492 492  
493 -F3.10=1 torque control upper limit source
493 +F3.10=1 Torque control upper limit source
494 494  
495 -F3.11=200 torque upper limit setting
495 +F3.11=200 Torque upper limit setting
496 496  
497 -F3.12=50 torque control maximum frequency
497 +F3.12=50 Torque control maximum frequency
498 498  
499 -F3.14=1.2 torque control acceleration time
499 +F3.14=1.2 Torque control acceleration time
500 500  
501 -F3.15=1.2 torque control deceleration time
501 +F3.15=1.2 Torque control deceleration time
502 502  
503 -F3.16 = 120 torque stiffness factor
503 +F3.16=120 Torque stiffness factor
504 504  
505 505  Torque control commissioning instructions:
506 506  
507 -F0.18: frequency acceleration time
507 +F0.18: Frequency acceleration time
508 508  
509 -F0.19: frequency deceleration time
509 +F0.19: Frequency deceleration time
510 510  
511 -F3.14: torque acceleration time
511 +F3.14: Torque acceleration time
512 512  
513 -F3.15: torque deceleration time
513 +F3.15: Torque deceleration time
514 514  
515 -F3.07: frequency low-pass filtering factor
515 +F3.07: Frequency low-pass filtering factor
516 516  
517 -F3.24: static friction compensation
517 +F3.24: Static friction compensation
518 518  
519 -F3.25: static friction compensation time
519 +F3.25: Static friction compensation time