Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
on 2024/04/22 13:56
Change comment:
There is no comment for this version
To version 30.1
edited by Theodore Xu
on 2024/04/23 10:32
on 2024/04/23 10:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -446,8 +446,13 @@ 446 446 447 447 The input terminal of the inverter has EMC screw access option. 448 448 449 -= Torque mode control winding project = 449 +(% style="text-align:center" %) 450 +[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 450 450 452 + 453 + 454 += Torque mode control on winding project = 455 + 451 451 Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 452 452 453 453 Debugging ideas: ... ... @@ -468,11 +468,11 @@ 468 468 469 469 F0.00=0 Vector control 470 470 471 -F0.18=2.0 acceleration time476 +F0.18=2.0 Acceleration time 472 472 473 -F0.19=2.0 deceleration time478 +F0.19=2.0 Deceleration time 474 474 475 -F2.01= motor rated power480 +F2.01=Motor rated power 476 476 477 477 F2.02=Motor rated voltage 478 478 ... ... @@ -482,38 +482,38 @@ 482 482 483 483 F2.05=Rated motor speed 484 484 485 -F2.11=1 static tuning490 +F2.11=1 Static tuning 486 486 487 -F3.01=0.2 speed loop integration time492 +F3.01=0.2 Speed loop integration time 488 488 489 -F3.07=0.005 speed loop filter coefficient494 +F3.07=0.005 Speed loop filter coefficient 490 490 491 -F3.09=1 torque control496 +F3.09=1 Torque control 492 492 493 -F3.10=1 torque control upper limit source498 +F3.10=1 Torque control upper limit source 494 494 495 -F3.11=200 torque upper limit setting500 +F3.11=200 Torque upper limit setting 496 496 497 -F3.12=50 torque control maximum frequency502 +F3.12=50 Torque control maximum frequency 498 498 499 -F3.14=1.2 torque control acceleration time504 +F3.14=1.2 Torque control acceleration time 500 500 501 -F3.15=1.2 torque control deceleration time506 +F3.15=1.2 Torque control deceleration time 502 502 503 -F3.16 torque stiffness factor508 +F3.16=120 Torque stiffness factor 504 504 505 505 Torque control commissioning instructions: 506 506 507 -F0.18: frequency acceleration time512 +F0.18: Frequency acceleration time 508 508 509 -F0.19: frequency deceleration time514 +F0.19: Frequency deceleration time 510 510 511 -F3.14: torque acceleration time516 +F3.14: Torque acceleration time 512 512 513 -F3.15: torque deceleration time518 +F3.15: Torque deceleration time 514 514 515 -F3.07: frequency low-pass filtering factor520 +F3.07: Frequency low-pass filtering factor 516 516 517 -F3.24: static friction compensation522 +F3.24: Static friction compensation 518 518 519 -F3.25: static friction compensation time524 +F3.25: Static friction compensation time
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +423.4 KB - Content