Changes for page 4 Common function of VB

Last modified by Theodore Xu on 2025/02/27 09:58

From version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
Change comment: There is no comment for this version
To version 33.1
edited by Theodore Xu
on 2024/04/23 19:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -442,12 +442,20 @@
442 442  
443 443  Braking resistor
444 444  
445 -= **Installation guidance required by EMC** =
445 += **EMC** =
446 446  
447 - The input terminal of the inverter has EMC screw access option.
447 + The input terminal of the inverter has EMC screw access option.
448 448  
449 -= Torque mode control winding project =
449 +* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground.
450 +* Role of removing EMC screws: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference.
450 450  
452 +(% style="text-align:center" %)
453 +[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
454 +
455 +
456 +
457 += Torque mode control on winding project =
458 +
451 451  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
452 452  
453 453  Debugging ideas:
... ... @@ -468,11 +468,11 @@
468 468  
469 469  F0.00=0 Vector control
470 470  
471 -F0.18=2.0 acceleration time
479 +F0.18=2.0 Acceleration time
472 472  
473 -F0.19=2.0 deceleration time
481 +F0.19=2.0 Deceleration time
474 474  
475 -F2.01=motor rated power
483 +F2.01=Motor rated power
476 476  
477 477  F2.02=Motor rated voltage
478 478  
... ... @@ -482,38 +482,38 @@
482 482  
483 483  F2.05=Rated motor speed
484 484  
485 -F2.11=1 static tuning
493 +F2.11=1 Static tuning
486 486  
487 -F3.01=0.2 speed loop integration time
495 +F3.01=0.2 Speed loop integration time
488 488  
489 -F3.07=0.005 speed loop filter coefficient
497 +F3.07=0.005 Speed loop filter coefficient
490 490  
491 -F3.09=1 torque control
499 +F3.09=1 Torque control
492 492  
493 -F3.10=1 torque control upper limit source
501 +F3.10=1 Torque control upper limit source
494 494  
495 -F3.11=200 torque upper limit setting
503 +F3.11=200 Torque upper limit setting
496 496  
497 -F3.12=50 torque control maximum frequency
505 +F3.12=50 Torque control maximum frequency
498 498  
499 -F3.14=1.2 torque control acceleration time
507 +F3.14=1.2 Torque control acceleration time
500 500  
501 -F3.15=1.2 torque control deceleration time
509 +F3.15=1.2 Torque control deceleration time
502 502  
503 -F3.16 = 120 torque stiffness factor
511 +F3.16=120 Torque stiffness factor
504 504  
505 505  Torque control commissioning instructions:
506 506  
507 -F0.18: frequency acceleration time
515 +F0.18: Frequency acceleration time
508 508  
509 -F0.19: frequency deceleration time
517 +F0.19: Frequency deceleration time
510 510  
511 -F3.14: torque acceleration time
519 +F3.14: Torque acceleration time
512 512  
513 -F3.15: torque deceleration time
521 +F3.15: Torque deceleration time
514 514  
515 -F3.07: frequency low-pass filtering factor
523 +F3.07: Frequency low-pass filtering factor
516 516  
517 -F3.24: static friction compensation
525 +F3.24: Static friction compensation
518 518  
519 -F3.25: static friction compensation time
527 +F3.25: Static friction compensation time
企业微信截图_16890580824807.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +423.4 KB
Content