Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
on 2024/04/22 13:56
Change comment:
There is no comment for this version
To version 34.1
edited by Theodore Xu
on 2024/04/23 19:51
on 2024/04/23 19:51
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -442,12 +442,25 @@ 442 442 443 443 Braking resistor 444 444 445 -= ** Installation guidance required byEMC** =445 += **EMC** = 446 446 447 - The input terminal of the inverter has EMC screw access option. 447 + The input terminal of the inverter has EMC screw access option. 448 448 449 -= Torque mode control winding project = 449 +* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground. 450 +* Role of removing EMC screws: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference. 450 450 452 +(% class="box infomessage" %) 453 +((( 454 +Do not remove the EMC unless there are special circumstances. 455 +))) 456 + 457 +(% style="text-align:center" %) 458 +[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 459 + 460 + 461 + 462 += Torque mode control on winding project = 463 + 451 451 Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 452 452 453 453 Debugging ideas: ... ... @@ -468,11 +468,11 @@ 468 468 469 469 F0.00=0 Vector control 470 470 471 -F0.18=2.0 acceleration time484 +F0.18=2.0 Acceleration time 472 472 473 -F0.19=2.0 deceleration time486 +F0.19=2.0 Deceleration time 474 474 475 -F2.01= motor rated power488 +F2.01=Motor rated power 476 476 477 477 F2.02=Motor rated voltage 478 478 ... ... @@ -482,38 +482,38 @@ 482 482 483 483 F2.05=Rated motor speed 484 484 485 -F2.11=1 static tuning498 +F2.11=1 Static tuning 486 486 487 -F3.01=0.2 speed loop integration time500 +F3.01=0.2 Speed loop integration time 488 488 489 -F3.07=0.005 speed loop filter coefficient502 +F3.07=0.005 Speed loop filter coefficient 490 490 491 -F3.09=1 torque control504 +F3.09=1 Torque control 492 492 493 -F3.10=1 torque control upper limit source506 +F3.10=1 Torque control upper limit source 494 494 495 -F3.11=200 torque upper limit setting508 +F3.11=200 Torque upper limit setting 496 496 497 -F3.12=50 torque control maximum frequency510 +F3.12=50 Torque control maximum frequency 498 498 499 -F3.14=1.2 torque control acceleration time512 +F3.14=1.2 Torque control acceleration time 500 500 501 -F3.15=1.2 torque control deceleration time514 +F3.15=1.2 Torque control deceleration time 502 502 503 -F3.16 torque stiffness factor516 +F3.16=120 Torque stiffness factor 504 504 505 505 Torque control commissioning instructions: 506 506 507 -F0.18: frequency acceleration time520 +F0.18: Frequency acceleration time 508 508 509 -F0.19: frequency deceleration time522 +F0.19: Frequency deceleration time 510 510 511 -F3.14: torque acceleration time524 +F3.14: Torque acceleration time 512 512 513 -F3.15: torque deceleration time526 +F3.15: Torque deceleration time 514 514 515 -F3.07: frequency low-pass filtering factor528 +F3.07: Frequency low-pass filtering factor 516 516 517 -F3.24: static friction compensation530 +F3.24: Static friction compensation 518 518 519 -F3.25: static friction compensation time532 +F3.25: Static friction compensation time
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +423.4 KB - Content