Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 3.1
edited by Stone Wu
on 2022/08/01 13:35
on 2022/08/01 13:35
Change comment:
There is no comment for this version
To version 16.1
edited by Theodore Xu
on 2023/09/19 10:18
on 2023/09/19 10:18
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Common function of VB 1 +4 Common function of VB - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -VFD. 3\. Demo.WebHome1 +VFD.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.AiXia - Content
-
... ... @@ -329,10 +329,8 @@ 329 329 330 330 F5.23=2 331 331 332 -= 333 -**Parameter protection** = 332 += **Parameter protection** = 334 334 335 - 336 336 ~1. The protection parameters cannot be modified and the parameters are locked. 337 337 338 338 F0.21=1 ... ... @@ -341,10 +341,8 @@ 341 341 342 342 FE.00 = non-zero number 343 343 344 -= 345 -**Set running time action** = 342 += **Set running time action** = 346 346 347 - 348 348 ~1. The customer sells the machine to the user, worrying that the customer did not pay on time, set some parameters inside the inverter. After the inverter has been running for 10 hours, the inverter will automatically stop and cannot start. Wait for the user to pay before the machine can run. How to set parameters for such a function? 349 349 FE.00=Set password 350 350 ... ... @@ -367,6 +367,8 @@ 367 367 368 368 = **PID function** = 369 369 366 +(% style="text-align:center" %) 367 +[[image:生产流程图.png]] 370 370 371 371 ~1. To be familiar with the PID function of constant pressure water supply, the feedback signal sources are remote pressure gauges and pressure transmitters. How to wire and which parameters should be set? For example, the maximum range of the remote pressure gauge is 1Mpa, and the current user needs to set the panel 0.45 MPa kg pressure, how to set the pressure? 372 372 F0.01=0 (panel start and stop)/1 (terminal start and stop) ... ... @@ -405,10 +405,8 @@ 405 405 406 406 Control operation command address: 2000H (premise F0.01=2) 407 407 408 -= 409 -**Safety and precautions** = 406 += **Safety and precautions** = 410 410 411 - 412 412 ~1. Familiar with product standard technical specifications. Please refer to the manual 413 413 414 414 = **Grounding** = ... ... @@ -417,10 +417,8 @@ 417 417 ~1. Understand the meaning and function of the ground wire and connect it correctly. 418 418 The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used. 419 419 420 -= 421 -**Peripheral lines** = 416 += **Peripheral lines** = 422 422 423 - 424 424 ~1. Understand the role of peripheral line equipment: 425 425 426 426 Open ... ... @@ -439,14 +439,11 @@ 439 439 440 440 Braking resistor 441 441 442 -= 443 -**Power and current value** = 436 += **Power and current value** = 444 444 445 - 446 446 ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 447 447 448 -= 449 -**Braking resistor** = 440 += **Braking resistor** = 450 450 451 451 452 452 ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? ... ... @@ -453,16 +453,13 @@ 453 453 454 454 Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 455 455 456 -= 457 -**Fault code and troubleshooting** = 447 += **Fault code and troubleshooting** = 458 458 459 459 460 460 ~1. Familiar with various fault codes and countermeasures to deal with faults. 461 461 462 -= 463 -**Installation guidance required by EMC** = 452 += **Installation guidance required by EMC** = 464 464 465 - 466 466 The input terminal of the inverter has EMC screw access option. 467 467 468 468
- PID原理图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.5 KB - Content
- 生产流程图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.0 MB - Content