... ... @@ -442,17 +442,12 @@
442 442  
443 443  Braking resistor
444 444  
445 -= **EMC** =
445 += **Installation guidance required by EMC** =
446 446  
447 - The input terminal of the inverter has EMC screw access option. This screw can be removed when the input power supply encounters electromagnetic interference, and in most cases does not need to be removed.
447 + The input terminal of the inverter has EMC screw access option.
448 448  
449 -(% style="text-align:center" %)
450 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
449 += Torque mode control winding project =
451 451  
452 -
453 -
454 -= Torque mode control on winding project =
455 -
456 456  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
457 457  
458 458  Debugging ideas:
... ... @@ -473,11 +473,11 @@
473 473  
474 474  F0.00=0 Vector control
475 475  
476 -F0.18=2.0 Acceleration time
471 +F0.18=2.0 acceleration time
477 477  
478 -F0.19=2.0 Deceleration time
473 +F0.19=2.0 deceleration time
479 479  
480 -F2.01=Motor rated power
475 +F2.01=motor rated power
481 481  
482 482  F2.02=Motor rated voltage
483 483  
... ... @@ -487,38 +487,38 @@
487 487  
488 488  F2.05=Rated motor speed
489 489  
490 -F2.11=1 Static tuning
485 +F2.11=1 static tuning
491 491  
492 -F3.01=0.2 Speed loop integration time
487 +F3.01=0.2 speed loop integration time
493 493  
494 -F3.07=0.005 Speed loop filter coefficient
489 +F3.07=0.005 speed loop filter coefficient
495 495  
496 -F3.09=1 Torque control
491 +F3.09=1 torque control
497 497  
498 -F3.10=1 Torque control upper limit source
493 +F3.10=1 torque control upper limit source
499 499  
500 -F3.11=200 Torque upper limit setting
495 +F3.11=200 torque upper limit setting
501 501  
502 -F3.12=50 Torque control maximum frequency
497 +F3.12=50 torque control maximum frequency
503 503  
504 -F3.14=1.2 Torque control acceleration time
499 +F3.14=1.2 torque control acceleration time
505 505  
506 -F3.15=1.2 Torque control deceleration time
501 +F3.15=1.2 torque control deceleration time
507 507  
508 -F3.16=120 Torque stiffness factor
503 +F3.16 = 120 torque stiffness factor
509 509  
510 510  Torque control commissioning instructions:
511 511  
512 -F0.18: Frequency acceleration time
507 +F0.18: frequency acceleration time
513 513  
514 -F0.19: Frequency deceleration time
509 +F0.19: frequency deceleration time
515 515  
516 -F3.14: Torque acceleration time
511 +F3.14: torque acceleration time
517 517  
518 -F3.15: Torque deceleration time
513 +F3.15: torque deceleration time
519 519  
520 -F3.07: Frequency low-pass filtering factor
515 +F3.07: frequency low-pass filtering factor
521 521  
522 -F3.24: Static friction compensation
517 +F3.24: static friction compensation
523 523  
524 -F3.25: Static friction compensation time
519 +F3.25: static friction compensation time