Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 33.1
edited by Theodore Xu
on 2024/04/23 19:49
on 2024/04/23 19:49
Change comment:
There is no comment for this version
To version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
on 2024/04/22 13:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -442,20 +442,12 @@ 442 442 443 443 Braking resistor 444 444 445 -= **EMC** = 445 += **Installation guidance required by EMC** = 446 446 447 - The input terminal of the inverter has EMC screw access option. 447 + The input terminal of the inverter has EMC screw access option. 448 448 449 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground. 450 -* Role of removing EMC screws: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference. 449 += Torque mode control winding project = 451 451 452 -(% style="text-align:center" %) 453 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 454 - 455 - 456 - 457 -= Torque mode control on winding project = 458 - 459 459 Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 460 460 461 461 Debugging ideas: ... ... @@ -476,11 +476,11 @@ 476 476 477 477 F0.00=0 Vector control 478 478 479 -F0.18=2.0 Acceleration time471 +F0.18=2.0 acceleration time 480 480 481 -F0.19=2.0 Deceleration time473 +F0.19=2.0 deceleration time 482 482 483 -F2.01= Motor rated power475 +F2.01=motor rated power 484 484 485 485 F2.02=Motor rated voltage 486 486 ... ... @@ -490,38 +490,38 @@ 490 490 491 491 F2.05=Rated motor speed 492 492 493 -F2.11=1 Static tuning485 +F2.11=1 static tuning 494 494 495 -F3.01=0.2 Speed loop integration time487 +F3.01=0.2 speed loop integration time 496 496 497 -F3.07=0.005 Speed loop filter coefficient489 +F3.07=0.005 speed loop filter coefficient 498 498 499 -F3.09=1 Torque control491 +F3.09=1 torque control 500 500 501 -F3.10=1 Torque control upper limit source493 +F3.10=1 torque control upper limit source 502 502 503 -F3.11=200 Torque upper limit setting495 +F3.11=200 torque upper limit setting 504 504 505 -F3.12=50 Torque control maximum frequency497 +F3.12=50 torque control maximum frequency 506 506 507 -F3.14=1.2 Torque control acceleration time499 +F3.14=1.2 torque control acceleration time 508 508 509 -F3.15=1.2 Torque control deceleration time501 +F3.15=1.2 torque control deceleration time 510 510 511 -F3.16=120 Torque stiffness factor503 +F3.16 = 120 torque stiffness factor 512 512 513 513 Torque control commissioning instructions: 514 514 515 -F0.18: Frequency acceleration time507 +F0.18: frequency acceleration time 516 516 517 -F0.19: Frequency deceleration time509 +F0.19: frequency deceleration time 518 518 519 -F3.14: Torque acceleration time511 +F3.14: torque acceleration time 520 520 521 -F3.15: Torque deceleration time513 +F3.15: torque deceleration time 522 522 523 -F3.07: Frequency low-pass filtering factor515 +F3.07: frequency low-pass filtering factor 524 524 525 -F3.24: Static friction compensation517 +F3.24: static friction compensation 526 526 527 -F3.25: Static friction compensation time519 +F3.25: static friction compensation time
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -423.4 KB - Content