Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 34.1
edited by Theodore Xu
on 2024/04/23 19:51
on 2024/04/23 19:51
Change comment:
There is no comment for this version
To version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
on 2024/04/22 13:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -442,25 +442,12 @@ 442 442 443 443 Braking resistor 444 444 445 -= **EMC** = 445 += **Installation guidance required by EMC** = 446 446 447 - The input terminal of the inverter has EMC screw access option. 447 + The input terminal of the inverter has EMC screw access option. 448 448 449 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground. 450 -* Role of removing EMC screws: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference. 449 += Torque mode control winding project = 451 451 452 -(% class="box infomessage" %) 453 -((( 454 -Do not remove the EMC unless there are special circumstances. 455 -))) 456 - 457 -(% style="text-align:center" %) 458 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 459 - 460 - 461 - 462 -= Torque mode control on winding project = 463 - 464 464 Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 465 465 466 466 Debugging ideas: ... ... @@ -481,11 +481,11 @@ 481 481 482 482 F0.00=0 Vector control 483 483 484 -F0.18=2.0 Acceleration time471 +F0.18=2.0 acceleration time 485 485 486 -F0.19=2.0 Deceleration time473 +F0.19=2.0 deceleration time 487 487 488 -F2.01= Motor rated power475 +F2.01=motor rated power 489 489 490 490 F2.02=Motor rated voltage 491 491 ... ... @@ -495,38 +495,38 @@ 495 495 496 496 F2.05=Rated motor speed 497 497 498 -F2.11=1 Static tuning485 +F2.11=1 static tuning 499 499 500 -F3.01=0.2 Speed loop integration time487 +F3.01=0.2 speed loop integration time 501 501 502 -F3.07=0.005 Speed loop filter coefficient489 +F3.07=0.005 speed loop filter coefficient 503 503 504 -F3.09=1 Torque control491 +F3.09=1 torque control 505 505 506 -F3.10=1 Torque control upper limit source493 +F3.10=1 torque control upper limit source 507 507 508 -F3.11=200 Torque upper limit setting495 +F3.11=200 torque upper limit setting 509 509 510 -F3.12=50 Torque control maximum frequency497 +F3.12=50 torque control maximum frequency 511 511 512 -F3.14=1.2 Torque control acceleration time499 +F3.14=1.2 torque control acceleration time 513 513 514 -F3.15=1.2 Torque control deceleration time501 +F3.15=1.2 torque control deceleration time 515 515 516 -F3.16=120 Torque stiffness factor503 +F3.16 = 120 torque stiffness factor 517 517 518 518 Torque control commissioning instructions: 519 519 520 -F0.18: Frequency acceleration time507 +F0.18: frequency acceleration time 521 521 522 -F0.19: Frequency deceleration time509 +F0.19: frequency deceleration time 523 523 524 -F3.14: Torque acceleration time511 +F3.14: torque acceleration time 525 525 526 -F3.15: Torque deceleration time513 +F3.15: torque deceleration time 527 527 528 -F3.07: Frequency low-pass filtering factor515 +F3.07: frequency low-pass filtering factor 529 529 530 -F3.24: Static friction compensation517 +F3.24: static friction compensation 531 531 532 -F3.25: Static friction compensation time519 +F3.25: static friction compensation time
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -423.4 KB - Content