... ... @@ -442,25 +442,12 @@
442 442  
443 443  Braking resistor
444 444  
445 -= **EMC** =
445 += **Installation guidance required by EMC** =
446 446  
447 - The input terminal of the inverter has EMC screw access option.
447 + The input terminal of the inverter has EMC screw access option.
448 448  
449 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground.
450 -* Role of removing EMC screws: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference.
449 += Torque mode control winding project =
451 451  
452 -(% class="box infomessage" %)
453 -(((
454 -Do not remove the EMC unless there are special circumstances.
455 -)))
456 -
457 -(% style="text-align:center" %)
458 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
459 -
460 -
461 -
462 -= Torque mode control on winding project =
463 -
464 464  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
465 465  
466 466  Debugging ideas:
... ... @@ -481,11 +481,11 @@
481 481  
482 482  F0.00=0 Vector control
483 483  
484 -F0.18=2.0 Acceleration time
471 +F0.18=2.0 acceleration time
485 485  
486 -F0.19=2.0 Deceleration time
473 +F0.19=2.0 deceleration time
487 487  
488 -F2.01=Motor rated power
475 +F2.01=motor rated power
489 489  
490 490  F2.02=Motor rated voltage
491 491  
... ... @@ -495,38 +495,38 @@
495 495  
496 496  F2.05=Rated motor speed
497 497  
498 -F2.11=1 Static tuning
485 +F2.11=1 static tuning
499 499  
500 -F3.01=0.2 Speed loop integration time
487 +F3.01=0.2 speed loop integration time
501 501  
502 -F3.07=0.005 Speed loop filter coefficient
489 +F3.07=0.005 speed loop filter coefficient
503 503  
504 -F3.09=1 Torque control
491 +F3.09=1 torque control
505 505  
506 -F3.10=1 Torque control upper limit source
493 +F3.10=1 torque control upper limit source
507 507  
508 -F3.11=200 Torque upper limit setting
495 +F3.11=200 torque upper limit setting
509 509  
510 -F3.12=50 Torque control maximum frequency
497 +F3.12=50 torque control maximum frequency
511 511  
512 -F3.14=1.2 Torque control acceleration time
499 +F3.14=1.2 torque control acceleration time
513 513  
514 -F3.15=1.2 Torque control deceleration time
501 +F3.15=1.2 torque control deceleration time
515 515  
516 -F3.16=120 Torque stiffness factor
503 +F3.16 = 120 torque stiffness factor
517 517  
518 518  Torque control commissioning instructions:
519 519  
520 -F0.18: Frequency acceleration time
507 +F0.18: frequency acceleration time
521 521  
522 -F0.19: Frequency deceleration time
509 +F0.19: frequency deceleration time
523 523  
524 -F3.14: Torque acceleration time
511 +F3.14: torque acceleration time
525 525  
526 -F3.15: Torque deceleration time
513 +F3.15: torque deceleration time
527 527  
528 -F3.07: Frequency low-pass filtering factor
515 +F3.07: frequency low-pass filtering factor
529 529  
530 -F3.24: Static friction compensation
517 +F3.24: static friction compensation
531 531  