... ... @@ -355,27 +355,26 @@ 355 355 356 356 = **Constant pressure water supply** = 357 357 358 -The following example uses a current sensor to simulate a water pressure test, the sensor specification is 4-20mA current signal, the range is 16 bar. use the sensor to connect to the AI2 terminal port of the VB. 359 -Firstly please check the software version of **F7.11**, **F7.11 **is software version, if the **F7.11 **is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 360 -F0.20=1 Factory data reset 358 + 359 +The following example uses a current transducer to simulate a water pressure test, the transducer specification is 4-20mA current signal, the range is 16 bar. use the transducer to connect to the AI2 terminal port of the VB. 360 +Please check the software version of F7.11 inverter first, if the software version is greater than 2.064, please use A4 parameter group, A4 parameter group is special parameter for constant pressure water supply project. 361 +F0.20=1 factory data reset 361 361 A4.00=1 362 -A4.01= Set pressure363 +A4.01=set pressure 363 363 A4.03=Sensor range 364 364 A4.04=0 365 365 366 366 If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 367 -F0.20=1 Factory data reset368 +F0.20=1 factory data reset 368 368 F0.03=8 369 369 F5.23=2 370 370 F9.01=Upper limit water pressure 371 371 F9.02=1 (AI2) 372 372 F9.28=1 373 -F9.29= Targetvalue374 +F9.29=Set pressure 374 374 F9.31=Lower limit water pressure 376 +In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it needs to be greater than or equal to F9.29, it is recommended to set F9.29=F9.01 375 375 376 - 377 -In the parameter setting of group F9, 20mA is the maximum value of the transducer with a range of 16bar, and F9.01/F9.29/F9.31 are the setting parameters for the water pressure in the VB in percentage. For example when the inverter is required to keep the pressure at 8bar, modify F9.29=50%. F9.01 is the upper limit of water pressure setting, it is recommended to set F9.29=F9.01,of course you can set F9.01=80%,it needs to be greater than or equal to F9.29. If when the control effect of the inverter is slow or the descent time is too long, try reducing the integration time: F9.06 = 0.5 or 1.0. 378 - 379 379 = **PID function** = 380 380 381 381 (% style="text-align:center" %) ... ... @@ -417,6 +417,10 @@ 417 417 418 418 Control operation command address: 2000H (premise F0.01=2) 419 419 419 += **Safety and precautions** = 420 + 421 +~1. Familiar with product standard technical specifications. Please refer to the manual 422 + 420 420 = **Grounding** = 421 421 422 422 ~1. Understand the meaning and function of the ground wire and connect it correctly. ... ... @@ -442,91 +442,20 @@ 442 442 443 443 Braking resistor 444 444 445 -= ** EMC** =448 += **Power and current value** = 446 446 447 - Theinput terminalof the inverterhasEMC screw accessoption.450 + ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 448 448 449 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground. 450 -* EMC Screw Removal Function: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference. 452 += **Braking resistor** = 451 451 452 -(% class="box infomessage" %) 453 -((( 454 -Do not remove the EMC unless there are special circumstances. 455 -))) 454 + ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? 456 456 457 -(% style="text-align:center" %) 458 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 456 +Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 459 459 460 - 458 += **Fault code and troubleshooting** = 461 461 462 - =Torquemode controlonwinding project=460 + ~1. Familiar with various fault codes and countermeasures to deal with faults. 463 463 464 - Torquemode canonly be vector control, torque controlreferstothe strength,thatinthetorque mode F0.03is theefaultvalue, modifyF0.03for other values is invalid.462 += **Installation guidance required by EMC** = 465 465 466 -Debugging ideas: 467 - 468 -~1. According to the application requirements of the torque command and the upper limit of the frequency. 469 - 470 -2. Set the frequency acceleration/deceleration time F0.18/F0.19 and the torque acceleration/deceleration time F3.14/F3.15, the torque acceleration/deceleration time is less than or equal to the frequency acceleration/deceleration time. 471 - 472 -3. Start the motor and observe whether the motor can run or not, if it can't run normally, rotate the motor with external force, if it can be started, it is judged to be necessary to increase the static friction coefficient compensation. 473 - 474 -4. After the motor is running, observe the motor running state, if the motor is blocked, check whether it is shaking when it is blocked, if it is shaking, increase F3.07, generally 0.01 amplitude increment. 475 - 476 -5. When the torque command F3.10 is lower than the percentage of "no-load current / rated current", the running frequency is about: rated frequency * torque command percentage * rated current / no-load current. 477 - 478 -6. Static Friction Compensation Logic: During startup, the torque command 1 = F3.11* F3.24 /100 is passed to the performance; after a maintenance time of F3.25 seconds, it reverts to torque command 2 = F3.11; the switching of torque commands 1 /2 occurs through the torque acceleration and deceleration times F3.14 / F3.15; 479 - 480 -7. Auxiliary debugging parameters: filter coefficient F3.07 and static friction compensation F3.24/ F3.25. 481 - 482 -F0.00=0 Vector control 483 - 484 -F0.18=2.0 Acceleration time 485 - 486 -F0.19=2.0 Deceleration time 487 - 488 -F2.01=Motor rated power 489 - 490 -F2.02=Motor rated voltage 491 - 492 -F2.03=Rated motor current 493 - 494 -F2.04=Rated motor frequency 495 - 496 -F2.05=Rated motor speed 497 - 498 -F2.11=1 Static tuning 499 - 500 -F3.01=0.2 Speed loop integration time 501 - 502 -F3.07=0.005 Speed loop filter coefficient 503 - 504 -F3.09=1 Torque control 505 - 506 -F3.10=1 Torque control upper limit source 507 - 508 -F3.11=200 Torque upper limit setting 509 - 510 -F3.12=50 Torque control maximum frequency 511 - 512 -F3.14=1.2 Torque control acceleration time 513 - 514 -F3.15=1.2 Torque control deceleration time 515 - 516 -F3.16=120 Torque stiffness factor 517 - 518 -Torque control commissioning instructions: 519 - 520 -F0.18: Frequency acceleration time 521 - 522 -F0.19: Frequency deceleration time 523 - 524 -F3.14: Torque acceleration time 525 - 526 -F3.15: Torque deceleration time 527 - 528 -F3.07: Frequency low-pass filtering factor 529 - 530 -F3.24: Static friction compensation 531 - 532 -F3.25: Static friction compensation time 464 + The input terminal of the inverter has EMC screw access option.
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -423.4 KB - Content