Changes for page 4 Common function of VB

Last modified by Theodore Xu on 2025/02/27 09:58

From version 36.1
edited by Theodore Xu
on 2024/07/31 11:00
Change comment: There is no comment for this version
To version 26.1
edited by Theodore Xu
on 2024/04/22 13:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,13 +11,3 @@
1 -= Parameters uploading and downloading =
2 -
3 -Parameter uploading and downloading is only supported between the same models.
4 -
5 -1.Press MF.K and ↑ and wait while the keyboard displays "u~-~-~-~-", the keyboard is uploading the parameters.
6 -
7 -2.Remove the keyboard and install to other VB.  Please be careful to align the pins when unplugging and plugging in the keyboard.
8 -
9 -3.Press MF.K and ↓ and wait while the keyboard display"d~-~-~-~-", the keyboard is downloading the parameters.
10 -
11 11  = **Start up** =
12 12  
13 13  ~1. Keyboard start and stop, panel potentiometer speed regulation. (F5.17 adjusts the change amplitude of the panel potentiometer)
... ... @@ -452,25 +452,12 @@
452 452  
453 453  Braking resistor
454 454  
455 -= **EMC** =
445 += **Installation guidance required by EMC** =
456 456  
457 - The input terminal of the inverter has EMC screw access option.
447 + The input terminal of the inverter has EMC screw access option.
458 458  
459 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground.
460 -* EMC Screw Removal Function: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference.
449 += Torque mode control winding project =
461 461  
462 -(% class="box infomessage" %)
463 -(((
464 -Do not remove the EMC unless there are special circumstances.
465 -)))
466 -
467 -(% style="text-align:center" %)
468 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
469 -
470 -
471 -
472 -= Torque mode control on winding project =
473 -
474 474  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
475 475  
476 476  Debugging ideas:
... ... @@ -491,11 +491,11 @@
491 491  
492 492  F0.00=0 Vector control
493 493  
494 -F0.18=2.0 Acceleration time
471 +F0.18=2.0 acceleration time
495 495  
496 -F0.19=2.0 Deceleration time
473 +F0.19=2.0 deceleration time
497 497  
498 -F2.01=Motor rated power
475 +F2.01=motor rated power
499 499  
500 500  F2.02=Motor rated voltage
501 501  
... ... @@ -505,38 +505,38 @@
505 505  
506 506  F2.05=Rated motor speed
507 507  
508 -F2.11=1 Static tuning
485 +F2.11=1 static tuning
509 509  
510 -F3.01=0.2 Speed loop integration time
487 +F3.01=0.2 speed loop integration time
511 511  
512 -F3.07=0.005 Speed loop filter coefficient
489 +F3.07=0.005 speed loop filter coefficient
513 513  
514 -F3.09=1 Torque control
491 +F3.09=1 torque control
515 515  
516 -F3.10=1 Torque control upper limit source
493 +F3.10=1 torque control upper limit source
517 517  
518 -F3.11=200 Torque upper limit setting
495 +F3.11=200 torque upper limit setting
519 519  
520 -F3.12=50 Torque control maximum frequency
497 +F3.12=50 torque control maximum frequency
521 521  
522 -F3.14=1.2 Torque control acceleration time
499 +F3.14=1.2 torque control acceleration time
523 523  
524 -F3.15=1.2 Torque control deceleration time
501 +F3.15=1.2 torque control deceleration time
525 525  
526 -F3.16=120 Torque stiffness factor
503 +F3.16 = 120 torque stiffness factor
527 527  
528 528  Torque control commissioning instructions:
529 529  
530 -F0.18: Frequency acceleration time
507 +F0.18: frequency acceleration time
531 531  
532 -F0.19: Frequency deceleration time
509 +F0.19: frequency deceleration time
533 533  
534 -F3.14: Torque acceleration time
511 +F3.14: torque acceleration time
535 535  
536 -F3.15: Torque deceleration time
513 +F3.15: torque deceleration time
537 537  
538 -F3.07: Frequency low-pass filtering factor
515 +F3.07: frequency low-pass filtering factor
539 539  
540 -F3.24: Static friction compensation
517 +F3.24: static friction compensation
541 541  
542 -F3.25: Static friction compensation time
519 +F3.25: static friction compensation time
企业微信截图_16890580824807.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -423.4 KB
Content