... ... @@ -1,18 +16,3 @@
1 -= Parameters uploading and downloading =
2 -
3 -(% class="box infomessage" %)
4 -(((
5 -**✎Note:**
6 -1.Parameter uploading and downloading is only supported between the same models.
7 -2.F7.11 shows the software version of the inverter, the parameters may differ between different versions, especially between 2.072 and versions below 2.072.
8 -)))
9 -
10 -1.Press MF.K and ↑ and wait while the keyboard displays "u~-~-~-~-", the keyboard is uploading the parameters.
11 -
12 -2.Remove the keyboard and install to other VB.  Please be careful to align the pins when unplugging and plugging in the keyboard.
13 -
14 -3.Press MF.K and ↓ and wait while the keyboard display"d~-~-~-~-", the keyboard is downloading the parameters.
15 -
16 16  = **Start up** =
17 17  
18 18  ~1. Keyboard start and stop, panel potentiometer speed regulation. (F5.17 adjusts the change amplitude of the panel potentiometer)
... ... @@ -457,25 +457,12 @@
457 457  
458 458  Braking resistor
459 459  
460 -= **EMC** =
445 += **Installation guidance required by EMC** =
461 461  
462 - The input terminal of the inverter has EMC screw access option.
447 + The input terminal of the inverter has EMC screw access option.
463 463  
464 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground.
465 -* EMC Screw Removal Function: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference.
449 += Torque mode control winding project =
466 466  
467 -(% class="box infomessage" %)
468 -(((
469 -Do not remove the EMC unless there are special circumstances.
470 -)))
471 -
472 -(% style="text-align:center" %)
473 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]]
474 -
475 -
476 -
477 -= Torque mode control on winding project =
478 -
479 479  Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid.
480 480  
481 481  Debugging ideas:
... ... @@ -528,7 +528,7 @@
528 528  
529 529  F3.15=1.2 Torque control deceleration time
530 530  
531 -F3.16=120 Torque stiffness factor
503 +F3.16 = 120 Torque stiffness factor
532 532  
533 533  Torque control commissioning instructions:
534 534  