Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 38.1
edited by Theodore Xu
on 2025/02/27 09:58
on 2025/02/27 09:58
Change comment:
There is no comment for this version
To version 28.1
edited by Theodore Xu
on 2024/04/22 14:31
on 2024/04/22 14:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,18 +16,3 @@ 1 -= Parameters uploading and downloading = 2 - 3 -(% class="box infomessage" %) 4 -((( 5 -**✎Note:** 6 -1.Parameter uploading and downloading is only supported between the same models. 7 -2.F7.11 shows the software version of the inverter, the parameters may differ between different versions, especially between 2.072 and versions below 2.072. 8 -))) 9 - 10 -1.Press MF.K and ↑ and wait while the keyboard displays "u~-~-~-~-", the keyboard is uploading the parameters. 11 - 12 -2.Remove the keyboard and install to other VB. Please be careful to align the pins when unplugging and plugging in the keyboard. 13 - 14 -3.Press MF.K and ↓ and wait while the keyboard display"d~-~-~-~-", the keyboard is downloading the parameters. 15 - 16 16 = **Start up** = 17 17 18 18 ~1. Keyboard start and stop, panel potentiometer speed regulation. (F5.17 adjusts the change amplitude of the panel potentiometer) ... ... @@ -381,7 +381,7 @@ 381 381 If the value of F7.11 is less than or equal to 2.064, use PID parameter group F9. 382 382 F0.20=1 Factory data reset 383 383 F0.03=8 384 -F5.23=2 Change AI2 range from 0-20mA to 4-20 mA.369 +F5.23=2 385 385 F9.01=Upper limit water pressure 386 386 F9.02=1 (AI2) 387 387 F9.28=1 ... ... @@ -457,25 +457,12 @@ 457 457 458 458 Braking resistor 459 459 460 -= **EMC** = 445 += **Installation guidance required by EMC** = 461 461 462 - The input terminal of the inverter has EMC screw access option. 447 + The input terminal of the inverter has EMC screw access option. 463 463 464 -* EMC Screws Installation Role: Filter out the common mode interference signals on the input side to the ground. 465 -* EMC Screw Removal Function: When the grounding of the whole equipment system is unstable, it is easy for the interference signal to enter the input terminal of the VFD, which leads to the inaccurate operation of the terminal motor, and then it is necessary to remove the EMC screws on the machine in order to solve the influence of external interference. 449 += Torque mode control winding project = 466 466 467 -(% class="box infomessage" %) 468 -((( 469 -Do not remove the EMC unless there are special circumstances. 470 -))) 471 - 472 -(% style="text-align:center" %) 473 -[[image:企业微信截图_16890580824807.png||height="394" width="284"]] 474 - 475 - 476 - 477 -= Torque mode control on winding project = 478 - 479 479 Torque mode can only be vector control, torque control refers to the strength, that in the torque mode F0.03 is the default value, modify F0.03 for other values is invalid. 480 480 481 481 Debugging ideas:
- 企业微信截图_16890580824807.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -423.4 KB - Content