Changes for page 4 Common function of VB
Last modified by Theodore Xu on 2025/02/27 09:58
From version 4.1
edited by Stone Wu
on 2022/08/01 13:35
on 2022/08/01 13:35
Change comment:
There is no comment for this version
To version 16.1
edited by Theodore Xu
on 2023/09/19 10:18
on 2023/09/19 10:18
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Common function of VB 1 +4 Common function of VB - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -VFD. 3\. Demo.WebHome1 +VFD.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.AiXia - Content
-
... ... @@ -339,10 +339,8 @@ 339 339 340 340 FE.00 = non-zero number 341 341 342 -= 343 -**Set running time action** = 342 += **Set running time action** = 344 344 345 - 346 346 ~1. The customer sells the machine to the user, worrying that the customer did not pay on time, set some parameters inside the inverter. After the inverter has been running for 10 hours, the inverter will automatically stop and cannot start. Wait for the user to pay before the machine can run. How to set parameters for such a function? 347 347 FE.00=Set password 348 348 ... ... @@ -365,6 +365,8 @@ 365 365 366 366 = **PID function** = 367 367 366 +(% style="text-align:center" %) 367 +[[image:生产流程图.png]] 368 368 369 369 ~1. To be familiar with the PID function of constant pressure water supply, the feedback signal sources are remote pressure gauges and pressure transmitters. How to wire and which parameters should be set? For example, the maximum range of the remote pressure gauge is 1Mpa, and the current user needs to set the panel 0.45 MPa kg pressure, how to set the pressure? 370 370 F0.01=0 (panel start and stop)/1 (terminal start and stop) ... ... @@ -403,10 +403,8 @@ 403 403 404 404 Control operation command address: 2000H (premise F0.01=2) 405 405 406 -= 407 -**Safety and precautions** = 406 += **Safety and precautions** = 408 408 409 - 410 410 ~1. Familiar with product standard technical specifications. Please refer to the manual 411 411 412 412 = **Grounding** = ... ... @@ -415,10 +415,8 @@ 415 415 ~1. Understand the meaning and function of the ground wire and connect it correctly. 416 416 The grounding terminal E of the inverter must be well grounded, the grounding resistance should be less than 102, and the grounding wire should be thick and short. Multi-strand copper core wire of 3.5mm2 or more should be used. 417 417 418 -= 419 -**Peripheral lines** = 416 += **Peripheral lines** = 420 420 421 - 422 422 ~1. Understand the role of peripheral line equipment: 423 423 424 424 Open ... ... @@ -437,14 +437,11 @@ 437 437 438 438 Braking resistor 439 439 440 -= 441 -**Power and current value** = 436 += **Power and current value** = 442 442 443 - 444 444 ~1. Familiar with the rated current of the inverter in different power ranges, please refer to the manual 445 445 446 -= 447 -**Braking resistor** = 440 += **Braking resistor** = 448 448 449 449 450 450 ~1. Familiar with the selection of braking resistor. Under what conditions do you need to install a braking resistor? How to install the braking resistor? ... ... @@ -451,16 +451,13 @@ 451 451 452 452 Braking resistors are installed on the and PB ends of the inverter (built-in braking unit) 453 453 454 -= 455 -**Fault code and troubleshooting** = 447 += **Fault code and troubleshooting** = 456 456 457 457 458 458 ~1. Familiar with various fault codes and countermeasures to deal with faults. 459 459 460 -= 461 -**Installation guidance required by EMC** = 452 += **Installation guidance required by EMC** = 462 462 463 - 464 464 The input terminal of the inverter has EMC screw access option. 465 465 466 466
- PID原理图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.5 KB - Content
- 生产流程图.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.0 MB - Content