Changes for page 09 Function code
Last modified by Iris on 2025/11/17 14:59
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1739,94 +1739,90 @@ 1739 1739 1740 1740 The VC series VFD standard unit has 2 multi-function relay output terminals, 1 FM terminal (which can be used as a high-speed pulse output terminal or as an open collector output), and 2 multi-function analog output terminals. 1741 1741 1742 -|(% rowspan="3" %)F6.00|(% colspan="2" %)FM Terminal output selection|Factory default|1 1743 -|(% rowspan="2" %)Setting range|0|(% colspan="2" %)Pulse output 1744 -|1|(% colspan="2" %)Open collector output (FMR) 1742 +|(% rowspan="3" style="text-align:center" %)F6.00|(% colspan="2" style="text-align:center" %)FM Terminal output selection|(% style="text-align:center" %)Factory default|1 1743 +|(% rowspan="2" style="text-align:center" %)Setting range|(% style="text-align:center" %)0|(% colspan="2" style="text-align:center" %)Pulse output 1744 +|(% style="text-align:center" %)1|(% colspan="2" style="text-align:center" %)Open collector output (FMR) 1745 1745 1746 1746 FM terminals are programmable multiplexed terminals. Can be used as a high speed pulse output terminal (FMP), pulse frequency up to 100kHz. Refer to F6.06 for FMP related functions. Also available as an open collector output terminal (FMR). See F6.01 for FMR functions. 1747 1747 1748 1748 FMP function needs hardware support. 1749 1749 1750 -|F6.01|FMR Open collector output selection|Factory default|0 1751 -|F6.02|Relay 1 output selection|Factory default|2 1752 -|F6.03|Relay 2 output selection (Extended)|Factory default|0 1753 -|F6.06|VDO1 output selection|Factory default|0 1754 -|F6.07|VDO2 output selection|Factory default|0 1755 -|F6.08|VDO3 output selection|Factory default|0 1750 +|(% style="text-align:center" %)F6.01|(% style="text-align:center" %)FMR Open collector output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1751 +|(% style="text-align:center" %)F6.02|(% style="text-align:center" %)Relay 1 output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2 1752 +|(% style="text-align:center" %)F6.03|(% style="text-align:center" %)Relay 2 output selection (Extended)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1753 +|(% style="text-align:center" %)F6.06|(% style="text-align:center" %)VDO1 output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1754 +|(% style="text-align:center" %)F6.07|(% style="text-align:center" %)VDO2 output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1755 +|(% style="text-align:center" %)F6.08|(% style="text-align:center" %)VDO3 output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1756 1756 1757 - 1758 - 1759 1759 Multi-function output terminal function selection are as follows: 1760 1760 1761 -|**Setting value**|**Function**|**Description** 1762 -|0|No-output|The output terminal has no function 1763 -|1|VFD in operation|Indicates that the inverter is running, there is an output frequency (can be zero) at this time output ON signal. 1764 -|2|Fault output|When the inverter fails and fails to stop, the output ON signal. 1765 -|3|Frequency level detects FDT arrival|Please refer to function codes F8.19 and F8.20 for detailed instructions 1766 -|4|Frequency arrival|Please refer to function code F8.26 for detailed instructions. 1767 -|5|Running at zero speed|The VFD operates and the output frequency is 0, and the output signal is ON. 1768 -|6|Motor overload pre-alarm|Before the motor electronic thermal protection action, according to the overload forecast value, after exceeding the forecast value output ON signal. Motor overload parameters are set in FA.00 to FA.02. 1769 -|7|Inverter overload pre-alarm|After checking the inverter overload, 10s before the protection occurs. Output ON signal. 1770 -|8|Set count pulse value to arrive|When the count value reaches the value set by FB.08, the ON signal is output. 1771 -|9|Specified count pulse value arrived|When the count value reaches the value set by FB.09, the ON signal is output. For the counting function, see FB group function description 1772 -|10|Length reached|When the actual length of the detection exceeds the length set by FB.05, the ON signal is output. 1773 -|11|PLC cycle complete|When the simple PLC completes a cycle, it outputs a pulse signal with a width of 250ms. 1774 -|12|Cumulative running time arrived|When the accumulated running time of the inverter exceeds the time set by F8.17, the output ON signal. 1775 -|13|-|- 1776 -|14|Torque limit|When the torque limit function is operated, the stall protection function automatically acts, automatically changes the output frequency, and the output ON signal indicates that the output torque is limited. This output signal can be used to reduce the load or to display an overload status signal on the monitoring device. 1777 -|15|Operational readiness|The main circuit and control circuit power supply are established, the inverter protection function is not active, and the inverter is in the running state, the ON signal is output. 1778 -|16|AI1>AI2|When the value of the analog input AI1 is greater than that of the other input AI2, the ON signal is output. 1779 -|17|Frequency upper limit reached|Output ON signal when the operating frequency reaches the upper limit frequency. 1780 -|18|((( 1759 +(% style="margin-left:auto; margin-right:auto" %) 1760 +|=**Setting value**|=**Function**|=**Description** 1761 +|=0|No-output|The output terminal has no function 1762 +|=1|VFD in operation|Indicates that the inverter is running, there is an output frequency (can be zero) at this time output ON signal. 1763 +|=2|Fault output|When the inverter fails and fails to stop, the output ON signal. 1764 +|=3|Frequency level detects FDT arrival|Please refer to function codes F8.19 and F8.20 for detailed instructions 1765 +|=4|Frequency arrival|Please refer to function code F8.26 for detailed instructions. 1766 +|=5|Running at zero speed|The VFD operates and the output frequency is 0, and the output signal is ON. 1767 +|=6|Motor overload pre-alarm|Before the motor electronic thermal protection action, according to the overload forecast value, after exceeding the forecast value output ON signal. Motor overload parameters are set in FA.00 to FA.02. 1768 +|=7|Inverter overload pre-alarm|After checking the inverter overload, 10s before the protection occurs. Output ON signal. 1769 +|=8|Set count pulse value to arrive|When the count value reaches the value set by FB.08, the ON signal is output. 1770 +|=9|Specified count pulse value arrived|When the count value reaches the value set by FB.09, the ON signal is output. For the counting function, see FB group function description 1771 +|=10|Length reached|When the actual length of the detection exceeds the length set by FB.05, the ON signal is output. 1772 +|=11|PLC cycle complete|When the simple PLC completes a cycle, it outputs a pulse signal with a width of 250ms. 1773 +|=12|Cumulative running time arrived|When the accumulated running time of the inverter exceeds the time set by F8.17, the output ON signal. 1774 +|=13|-|- 1775 +|=14|Torque limit|When the torque limit function is operated, the stall protection function automatically acts, automatically changes the output frequency, and the output ON signal indicates that the output torque is limited. This output signal can be used to reduce the load or to display an overload status signal on the monitoring device. 1776 +|=15|Operational readiness|The main circuit and control circuit power supply are established, the inverter protection function is not active, and the inverter is in the running state, the ON signal is output. 1777 +|=16|AI1>AI2|When the value of the analog input AI1 is greater than that of the other input AI2, the ON signal is output. 1778 +|=17|Frequency upper limit reached|Output ON signal when the operating frequency reaches the upper limit frequency. 1779 +|=18|((( 1781 1781 Frequency lower limit reached 1782 1782 1783 1783 (Run related) 1784 1784 )))|Output ON signal when the operating frequency reaches the lower limit frequency. In the shutdown state, the signal is always OFF. 1785 -|19|Undervoltage state output|The inverter outputs ON signal when it is undervoltage. 1786 -|20|Communication setting|See related instructions in the communication protocol 1787 -|21|Positioning completed|Reserve 1788 -|22|Positioning close|Reserve 1789 -|23|((( 1784 +|=19|Undervoltage state output|The inverter outputs ON signal when it is undervoltage. 1785 +|=20|Communication setting|See related instructions in the communication protocol 1786 +|=21|Positioning completed|Reserve 1787 +|=22|Positioning close|Reserve 1788 +|=23|((( 1790 1790 Zero speed running 2 1791 1791 1792 1792 (Also output when shut down) 1793 1793 )))|VFD output frequency is 0, output ON signal (shutdown also output). 1794 -|24|Accumulative power-on time reached|When F7.13(the accumulated power-on time of the inverter) exceeds the time set by F8.16, the ON signal is output. 1795 -|25|((( 1793 +|=24|Accumulative power-on time reached|When F7.13(the accumulated power-on time of the inverter) exceeds the time set by F8.16, the ON signal is output. 1794 +|=25|((( 1796 1796 Frequency level detection 1797 1797 1798 1798 FDT2 output 1799 1799 )))|For details, see function codes F8.28 and F8.29. 1800 -|26|Frequency to 1 output|For details, see function codes F8.30 and F8.31. 1801 -|27|Frequency to 2output|For details, see function codes F8.32 and F8.33. 1802 -|28|Current reaches 1 output|For details, see function codes F8.38 and F8.39. 1803 -|29|Current reaches 2 output|For details, see function codes F8.40 and F8.41. 1804 -|30|Timed arrival output|When F8.42(timing function selection) is effective, the VFD will output ON signal when the running time reaches the set timing time. 1805 -|31|-|- 1806 -|32|-| 1807 -|33|Running direction|When the inverter runs in reverse, the ON signal is output 1808 -|34|-| 1809 -|35|Module temperature reach| 1810 -|36|Software overcurrent output|For details, see function codes F8.36 and F8.37. 1811 -|37|((( 1799 +|=26|Frequency to 1 output|For details, see function codes F8.30 and F8.31. 1800 +|=27|Frequency to 2output|For details, see function codes F8.32 and F8.33. 1801 +|=28|Current reaches 1 output|For details, see function codes F8.38 and F8.39. 1802 +|=29|Current reaches 2 output|For details, see function codes F8.40 and F8.41. 1803 +|=30|Timed arrival output|When F8.42(timing function selection) is effective, the VFD will output ON signal when the running time reaches the set timing time. 1804 +|=31|-|- 1805 +|=32|-| 1806 +|=33|Running direction|When the inverter runs in reverse, the ON signal is output 1807 +|=34|-| 1808 +|=35|Module temperature reach| 1809 +|=36|Software overcurrent output|For details, see function codes F8.36 and F8.37. 1810 +|=37|((( 1812 1812 Lower limit frequency reached 1813 1813 1814 1814 (Run independent) 1815 1815 )))|Output ON signal when the operating frequency reaches the lower limit frequency. (When the conditions are met, the ON signal will also be output in the shutdown state) 1816 -|38|Fault output (Continue running)|When the inverter fails, output ON signal 1817 -|39|Reserve| 1818 -|40|The running time arrive| 1819 -|41|User defined output 1|User can define the conditions to output the terminal 1820 -|42|User-defined output 2|User can define the conditions to output the terminal 1821 -|43|Timer output|Output ON signal when the timing setting condition is met 1822 -|44|Forward running status|If the inverter is in forward running, output ON signal 1823 -|45|Reverse running status|If the inverter is in reverse running, output ON signal 1815 +|=38|Fault output (Continue running)|When the inverter fails, output ON signal 1816 +|=39|Reserve| 1817 +|=40|The running time arrive| 1818 +|=41|User defined output 1|User can define the conditions to output the terminal 1819 +|=42|User-defined output 2|User can define the conditions to output the terminal 1820 +|=43|Timer output|Output ON signal when the timing setting condition is met 1821 +|=44|Forward running status|If the inverter is in forward running, output ON signal 1822 +|=45|Reverse running status|If the inverter is in reverse running, output ON signal 1824 1824 1825 - 1826 - 1827 - 1828 -|(% rowspan="2" %)F6.10|AO output signal selection|Factory default|00 1829 -|Setting range|(% colspan="2" %)((( 1824 +|(% rowspan="2" style="text-align:center" %)F6.10|(% style="text-align:center" %)AO output signal selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)00 1825 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 1830 1830 The ones place: AO1 1831 1831 1832 1832 0: 0 to 10V ... ... @@ -1846,8 +1846,8 @@ 1846 1846 1847 1847 All models 1 AO. 1848 1848 1849 -|(% rowspan="2" %)F6.11|FMP (Pulse output terminal) output selection|Factory default|0 1850 -|Setting range|(% colspan="2" %)((( 1845 +|(% rowspan="2" style="text-align:center" %)F6.11|(% style="text-align:center" %)FMP (Pulse output terminal) output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1846 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 1851 1851 0: Running frequency 1852 1852 1853 1853 1: Set the frequency ... ... @@ -1882,88 +1882,84 @@ 1882 1882 1883 1883 16: Bus voltage (0-1000V, corresponding to 0-10V) 1884 1884 ))) 1885 -|(% rowspan="2" %)F6.12|AO1 output selection|Factory default|0 1886 -|Setting range|(% colspan="2" %)Consistent with F6.11 setting range 1887 -|(% rowspan="2" %)F6.13|AO2 output selection (Extended)|Factory default|0 1888 -|Setting range|(% colspan="2" %)Consistent with F6.11 setting range 1881 +|(% rowspan="2" style="text-align:center" %)F6.12|(% style="text-align:center" %)AO1 output selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1882 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)Consistent with F6.11 setting range 1883 +|(% rowspan="2" style="text-align:center" %)F6.13|(% style="text-align:center" %)AO2 output selection (Extended)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1884 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)Consistent with F6.11 setting range 1889 1889 1890 1890 The standard output of the analog output (zero bias is 0, gain 1) is 0mA to 20mA (or 0V to 10V). 1891 1891 1892 1892 The range of corresponding quantities represented is shown in the following table: 1893 1893 1894 -|**Setting value**|**Function**|**Range** 1895 -|0|Operating frequency|0 to Maximum output frequency 1896 -|1|Setting frequency|0 toMaximum output frequency 1897 -|2|Output current|0 to2 times the rated motor current 1898 -|3|Output torque|0 to2 times the rated motor torque 1899 -|4|Output power|0 to 2 times rated power 1900 -|5|Output voltage|0 to 1.2 times rated voltage of inverter 1901 -|6|(% colspan="2" %)Reserve 1902 -|7|AI1|0V to10V 1903 -|8|AI2|0V to10V/0-20mA 1904 -|9|(% colspan="2" %)Reserve 1905 -|10|Length|0 to Maximum set length 1906 -|11|Count value|0 to Maximum count value 1907 -|12|Communication setting|-10000 to 10000 1908 -|13|Motor speed|0 to The maximum output frequency corresponds to the speed 1909 -|14|Output current|0 to 1000A, correspondence 0-10V 1910 -0 to 1000V, correspondence 0-10V 1911 -|15|Output voltage|0.0V to 1000.0V 1912 -|16|Bus voltage|0 to 1000V, correspondence 0-10V 1890 +(% style="margin-left:auto; margin-right:auto" %) 1891 +|=**Setting value**|=**Function**|=**Range** 1892 +|=0|(% style="text-align:center" %)Operating frequency|(% style="text-align:center" %)0 to Maximum output frequency 1893 +|=1|(% style="text-align:center" %)Setting frequency|(% style="text-align:center" %)0 to Maximum output frequency 1894 +|=2|(% style="text-align:center" %)Output current|(% style="text-align:center" %)0 to 2 times the rated motor current 1895 +|=3|(% style="text-align:center" %)Output torque|(% style="text-align:center" %)0 to 2 times the rated motor torque 1896 +|=4|(% style="text-align:center" %)Output power|(% style="text-align:center" %)0 to 2 times rated power 1897 +|=5|(% style="text-align:center" %)Output voltage|(% style="text-align:center" %)0 to 1.2 times rated voltage of inverter 1898 +|=6|(% colspan="2" style="text-align:center" %)Reserve 1899 +|=7|(% style="text-align:center" %)AI1|(% style="text-align:center" %)0V to10V 1900 +|=8|(% style="text-align:center" %)AI2|(% style="text-align:center" %)0V to 10V/0-20mA 1901 +|=9|(% colspan="2" style="text-align:center" %)Reserve 1902 +|=10|(% style="text-align:center" %)Length|(% style="text-align:center" %)0 to Maximum set length 1903 +|=11|(% style="text-align:center" %)Count value|(% style="text-align:center" %)0 to Maximum count value 1904 +|=12|(% style="text-align:center" %)Communication setting|(% style="text-align:center" %)-10000 to 10000 1905 +|=13|(% style="text-align:center" %)Motor speed|(% style="text-align:center" %)0 to The maximum output frequency corresponds to the speed 1906 +|=14|(% style="text-align:center" %)Output current|(% style="text-align:center" %)0 to 1000A, correspondence 0 to 10V 1907 +0 to 1000V, correspondence 0 to 10V 1908 +|=15|(% style="text-align:center" %)Output voltage|(% style="text-align:center" %)0.0V to 1000.0V 1909 +|=16|(% style="text-align:center" %)Bus voltage|(% style="text-align:center" %)0 to 1000V, correspondence 0 to 10V 1913 1913 1911 +|(% rowspan="2" style="text-align:center" %)F6.14|(% style="text-align:center" %)FM upper frequency output limit|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.00kHz 1912 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 100.00kHz 1914 1914 1915 - 1916 -|(% rowspan="2" %)F6.14|FM upper frequency output limit|Factory default|20.00kHz 1917 -|Setting range|(% colspan="2" %)0.00 to- 50.00kHz 1918 - 1919 - 1920 - 1921 1921 F6.00 maximum frequency of pulse output when selecting pulse output. 1922 1922 1923 -|(% rowspan="2" %)F6.15|AO1 minimum input|Factory default|0.00V 1924 -|Setting range|(% colspan="2" %)0.00V to F6.17 1925 -|(% rowspan="2" %)F6.16|AO1 the minimum input corresponds to the setting|Factory default|0.0% 1926 -|Setting range|(% colspan="2" %)0.0% to +100.0% 1927 -|(% rowspan="2" %)F6.17|AO1 maximum input|Factory default|10.00V 1928 -|Setting range|(% colspan="2" %)F6.15 to +10.00V 1929 -|(% rowspan="2" %)F6.18|AO1 the maximum input corresponds to the setting|Factory default|100.0% 1930 -|Setting range|(% colspan="2" %)0.0% to +100.0% 1916 +|(% rowspan="2" style="text-align:center" %)F6.15|(% style="text-align:center" %)AO1 minimum input|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00V 1917 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00V to F6.17 1918 +|(% rowspan="2" style="text-align:center" %)F6.16|(% style="text-align:center" %)AO1 the minimum input corresponds to the setting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 1919 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to +100.0% 1920 +|(% rowspan="2" style="text-align:center" %)F6.17|(% style="text-align:center" %)AO1 maximum input|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)10.00V 1921 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)F6.15 to +10.00V 1922 +|(% rowspan="2" style="text-align:center" %)F6.18|(% style="text-align:center" %)AO1 the maximum input corresponds to the setting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 1923 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to +100.0% 1931 1931 1932 1932 The above function code defines the relationship between the analog output voltage and the set value represented by the analog output. When the analog output voltage exceeds the set maximum output range, the other part will be calculated as the maximum output; when the analog output voltage exceeds the set minimum output range, the other part will be calculated according to the AO minimum output. When the analog output is a current output, 1mA current is equivalent to 0.5V voltage. In different applications, the nominal value corresponding to the simulated 100% is different, please refer to the description of each application. 1933 1933 1934 -|(% rowspan="2" %)F6.19|AO2 minimum input (Extended)|Factory default|(% colspan="2" %)0.00V 1935 -|Setting range|(% colspan="3" %)0.00V to F6.21 1936 -|(% rowspan="2" %)F6.20|AO2 minimum Input mapping Settings (Extended)|(% colspan="2" %)Factory default|0.0% 1937 -|Setting range|(% colspan="3" %)0.0% to +100.0% 1938 -|(% rowspan="2" %)F6.21|AO2 maximum input (Extended)|(% colspan="2" %)Factory default|10.00V 1939 -|Setting range|(% colspan="3" %)F6.19 to +10.00V 1940 -|(% rowspan="2" %)F6.22|AO2 maximum input corresponding Settings (Extended)|(% colspan="2" %)Factory default|100.0% 1941 -|Setting range|(% colspan="3" %)0.0% to +100.0% 1942 -|(% rowspan="2" %)F6.23|FMR turn-on delay time|(% colspan="2" %)Factory default|0.0s 1943 -|Setting range|(% colspan="3" %)0.0s to 3600.0s 1927 +|(% rowspan="2" style="text-align:center" %)F6.19|(% style="text-align:center" %)AO2 minimum input (Extended)|(% style="text-align:center" %)Factory default|(% colspan="2" style="text-align:center" %)0.00V 1928 +|(% style="text-align:center" %)Setting range|(% colspan="3" style="text-align:center" %)0.00V to F6.21 1929 +|(% rowspan="2" style="text-align:center" %)F6.20|(% style="text-align:center" %)AO2 minimum Input mapping Settings (Extended)|(% colspan="2" style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 1930 +|(% style="text-align:center" %)Setting range|(% colspan="3" style="text-align:center" %)0.0% to +100.0% 1931 +|(% rowspan="2" style="text-align:center" %)F6.21|(% style="text-align:center" %)AO2 maximum input (Extended)|(% colspan="2" style="text-align:center" %)Factory default|(% style="text-align:center" %)10.00V 1932 +|(% style="text-align:center" %)Setting range|(% colspan="3" style="text-align:center" %)F6.19 to +10.00V 1933 +|(% rowspan="2" style="text-align:center" %)F6.22|(% style="text-align:center" %)AO2 maximum input corresponding Settings (Extended)|(% colspan="2" style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 1934 +|(% style="text-align:center" %)Setting range|(% colspan="3" style="text-align:center" %)0.0% to +100.0% 1935 +|(% rowspan="2" style="text-align:center" %)F6.23|(% style="text-align:center" %)FMR turn-on delay time|(% colspan="2" style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1936 +|(% style="text-align:center" %)Setting range|(% colspan="3" style="text-align:center" %)0.0s to 3600.0s 1944 1944 1945 1945 The above function code defines the relationship between the analog output voltage and the set value represented by the analog output. When the analog output voltage exceeds the set maximum output range, the other part will be calculated as the maximum output; when the analog output voltage exceeds the set minimum output range, the other part will be calculated according to the AO minimum output. When the analog output is a current output, 1mA current is equivalent to 0.5V voltage. In different applications, the nominal value corresponding to the simulated 100% is different, please refer to the description of each application. 1946 1946 1940 +|(% rowspan="2" style="text-align:center" %)F6.24|(% style="text-align:center" %)Relay 1 on delay time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1941 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1942 +|(% rowspan="2" style="text-align:center" %)F6.25|(% style="text-align:center" %)Relay 2 turn-on delay time (Extended)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1943 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1944 +|(% rowspan="2" style="text-align:center" %)F6.26|(% style="text-align:center" %)VDO connection delay|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1945 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1946 +|(% rowspan="2" style="text-align:center" %)F6.27|(% style="text-align:center" %)FMR disconnect delay time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1947 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1948 +|(% rowspan="2" style="text-align:center" %)F6.28|(% style="text-align:center" %)Relay 1 disconnect delay time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1949 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1950 +|(% rowspan="2" style="text-align:center" %)F6.29|(% style="text-align:center" %)Relay 2 disconnect delay time (Extended)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1951 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1952 +|(% rowspan="2" style="text-align:center" %)F6.30|(% style="text-align:center" %)VDO1 disconnect delay|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 1953 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 3600.0s 1947 1947 1948 -|(% rowspan="2" %)F6.24|Relay 1 on delay time|Factory default|0.0s 1949 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1950 -|(% rowspan="2" %)F6.25|Relay 2 turn-on delay time (Extended)|Factory default|0.0s 1951 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1952 -|(% rowspan="2" %)F6.26|VDO connection delay|Factory default|0.0s 1953 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1954 -|(% rowspan="2" %)F6.27|FMR disconnect delay time|Factory default|0.0s 1955 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1956 -|(% rowspan="2" %)F6.28|Relay 1 disconnect delay time|Factory default|0.0s 1957 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1958 -|(% rowspan="2" %)F6.29|Relay 2 disconnect delay time (Extended)|Factory default|0.0s 1959 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1960 -|(% rowspan="2" %)F6.30|VDO1 disconnect delay|Factory default|0.0s 1961 -|Setting range|(% colspan="2" %)0.0s to 3600.0s 1962 - 1963 1963 Set the delay time of output terminals FMR, relay 1, relay 2, VDO from the change of state to the change of output. 1964 1964 1965 -|(% rowspan="2" %)F6.31|Output terminal valid status Select 1|Factory default|000 1966 -|Setting range|(% colspan="2" %)((( 1957 +|(% rowspan="2" style="text-align:center" %)F6.31|(% style="text-align:center" %)Output terminal valid status Select 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)000 1958 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 1967 1967 0: Positive logic 1968 1968 1969 1969 1: Reverse logic ... ... @@ -1976,8 +1976,8 @@ 1976 1976 1977 1977 Thousands place: - 1978 1978 ))) 1979 -|(% rowspan="2" %)F6.32|Virtual output terminal valid status Select 2|Factory default|000 1980 -|Setting range|(% colspan="2" %)((( 1971 +|(% rowspan="2" style="text-align:center" %)F6.32|(% style="text-align:center" %)Virtual output terminal valid status Select 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)000 1972 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 1981 1981 0: Positive logic 1982 1982 1983 1983 1: Reverse logic ... ... @@ -1997,8 +1997,8 @@ 1997 1997 1998 1998 Inverse logic: The digital output terminal is not connected to the corresponding public end, and the disconnect is valid. 1999 1999 2000 -|(% rowspan="2" %)F6.33|User-defined output selection (EX) 1|Factory default|0 2001 -|Setting range|(% colspan="2" %)((( 1992 +|(% rowspan="2" style="text-align:center" %)F6.33|(% style="text-align:center" %)User-defined output selection (EX) 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 1993 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2002 2002 0: The running frequency 2003 2003 2004 2004 1: Set the frequency ... ... @@ -2024,9 +2024,8 @@ 2024 2024 2025 2025 This parameter is used to select a reference variable for the custom output. Take the selected variable EX as the operation comparison object. 2026 2026 2027 - 2028 -|(% rowspan="2" %)F6.34|The comparison method chosen by the user 1|Factory default|0 2029 -|Setting range|(% colspan="2" %)((( 2019 +|(% rowspan="2" style="text-align:center" %)F6.34|(% style="text-align:center" %)The comparison method chosen by the user 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2020 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2030 2030 Units: Compare test methods 2031 2031 2032 2032 0: Equal to (EX == X1) ... ... @@ -2050,17 +2050,17 @@ 2050 2050 2051 2051 The way the tens select the output. False value output is output if the condition is not met, and no output if it is met; Truth output is output only when the condition is met, and no output if the condition is not met. 2052 2052 2053 -|(% rowspan="2" %)F6.35|User-defined dead zone 1|Factory default|0 2054 -|Setting range|(% colspan="2" %)0 to 65535 2044 +|(% rowspan="2" style="text-align:center" %)F6.35|(% style="text-align:center" %)User-defined dead zone 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2045 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2055 2055 2056 2056 When the comparison test mode of F6.29 is set to greater than or equal to or less than or equal to, F6.30 is used to define the processing dead zone value centered on the comparison value X1. The processing dead zone has effect only on 1 and 2 of the comparison test mode of F6.29, and has no effect on 0, 3, and 4. For example, when F6.29 is set to 11, when EX is increased from 0 to greater than or equal to X1+F6.30, the output is valid; When EX is reduced to less than or equal to X1.F6.30, the output is invalid. 2057 2057 2058 -|(% rowspan="2" %)F6.36|User-defined 2 outputs the comparison value X1|Factory default|0 2059 -|Setting range|(% colspan="2" %)0 to 65535 2060 -|(% rowspan="2" %)F6.37|User-defined 2 outputs the comparison value X2|Factory default|0 2061 -|Setting range|(% colspan="2" %)0 to 65535 2062 -|(% rowspan="2" %)F6.38|User-defined output selection (EX) 2|Factory default|0 2063 -|Setting range|(% colspan="2" %)((( 2049 +|(% rowspan="2" style="text-align:center" %)F6.36|(% style="text-align:center" %)User-defined 2 outputs the comparison value X1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2050 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2051 +|(% rowspan="2" style="text-align:center" %)F6.37|(% style="text-align:center" %)User-defined 2 outputs the comparison value X2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2052 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2053 +|(% rowspan="2" style="text-align:center" %)F6.38|(% style="text-align:center" %)User-defined output selection (EX) 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2054 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2064 2064 0: Running frequency 2065 2065 2066 2066 1: Set the frequency ... ... @@ -2090,22 +2090,22 @@ 2090 2090 2091 2091 ~1. When the set frequency is greater than or equal to 20.00HZ, the relay is closed; 2092 2092 2093 -Set parameters as follows: F6.02 = 41 ,F6.28= 1,F6.29= 11,F6.30= 0,F6.31= 2000;2084 +Set parameters as follows: F6.02 = 41,F6.33 = 1,F6.34 = 11,F6.35 = 0,F6.36 = 2000; 2094 2094 2095 2095 2. When the bus voltage is less than or equal to 500.0V, the relay is closed; In order to avoid frequent operation of the relay when the detection voltage fluctuates 5.0V above and below 500.0V, it is required to process into a dead zone in the range of (500.0-5.0) to (500.0+5.0). 2096 2096 2097 -Set parameters as follows: F6.02 = 41 ,F6.28= 2,F6.29= 01,F6.30= 50,F6.31= 5000;2088 +Set parameters as follows: F6.02 = 41,F6.33 = 2,F6.34 = 01,F6.35 = 50,F6.36 = 5000; 2098 2098 2099 2099 3. When the inverter is required to reverse, the relay is closed: 2100 2100 2101 -Set parameters as follows: F6.02 = 41 ,F6.28=5,F6.29= 14,F6.31 = 8,F6.32= 8;2092 +Set parameters as follows: F6.02 = 41,F6.33 = 2,F6.34 = 01,F6.31 = 8,F6.37= 8; 2102 2102 2103 2103 4. When AI1 input is required to be greater than 3.00V and less than or equal to 6.00V, the relay is closed: 2104 2104 2105 -Set parameters as follows: F6.02 = 41 ,F6.28=13,F6.29=13,F6.31=300,F6.32=600; F6.33 to F6.37 is the same as F6.28 to F6.32.2096 +Set parameters as follows: F6.02 = 41,F6.33=13,F6.34=13,F6.36=300,F6.37=600 2106 2106 2107 -|(% rowspan="2" %)F6.39|The comparison method chosen by the user 2|Factory default|0 2108 -|Setting range|(% colspan="2" %)((( 2098 +|(% rowspan="2" style="text-align:center" %)F6.39|(% style="text-align:center" %)The comparison method chosen by the user 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2099 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2109 2109 Units: Compare test methods 2110 2110 2111 2111 0: Equal to (EX == X1) ... ... @@ -2124,18 +2124,17 @@ 2124 2124 2125 2125 1: Truth output 2126 2126 ))) 2127 -|(% rowspan="2" %)F6.40|User-defined dead zone 2|Factory default|0 2128 -|Setting range|(% colspan="2" %)0 to 65535 2129 -|(% rowspan="2" %)F6.41|User-defined 2 outputs the comparison value X1|Factory default|0 2130 -|Setting range|(% colspan="2" %)0 to 65535 2131 -|(% rowspan="2" %)F6.42|User-defined 2 Output comparison value X2|Factory default|0 2132 -|Setting range|(% colspan="2" %)0 to 65535 2118 +|(% rowspan="2" style="text-align:center" %)F6.40|(% style="text-align:center" %)User-defined dead zone 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2119 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2120 +|(% rowspan="2" style="text-align:center" %)F6.41|(% style="text-align:center" %)User-defined 2 outputs the comparison value X1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2121 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2122 +|(% rowspan="2" style="text-align:center" %)F6.42|(% style="text-align:center" %)User-defined 2 Output comparison value X2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2123 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2133 2133 2134 2134 Second output. The parameter setting mode is the same as F6.33 to F6.37. 2135 2135 2136 - 2137 -|(% rowspan="2" %)F6.43|Timer time unit|Factory default|0 2138 -|Setting range|(% colspan="2" %)((( 2127 +|(% rowspan="2" style="text-align:center" %)F6.43|(% style="text-align:center" %)Timer time unit|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2128 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 2139 2139 0: Second 2140 2140 2141 2141 1: Minute ... ... @@ -2142,22 +2142,21 @@ 2142 2142 2143 2143 2: Hour 2144 2144 ))) 2145 -|(% rowspan="2" %)F6.44|Timer maximum|Factory default|0 2146 -|Setting range|(% colspan="2" %)0 to 65535 (No more when set to 65000) 2147 -|(% rowspan="2" %)F6.45|Timer set value|Factory default|0 2148 -|Setting range|(% colspan="2" %)0 to 65535 2149 -|(% rowspan="2" %)F6.46|Counter maximum|Factory default|0 2150 -|Setting range|(% colspan="2" %)0 to 65535 2151 -|(% rowspan="2" %)F6.47|Counter set value|Factory default|0 2152 -|Setting range|(% colspan="2" %)0 to 65535 2135 +|(% rowspan="2" style="text-align:center" %)F6.44|(% style="text-align:center" %)Timer maximum|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2136 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 (No more when set to 65000) 2137 +|(% rowspan="2" style="text-align:center" %)F6.45|(% style="text-align:center" %)Timer set value|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2138 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2139 +|(% rowspan="2" style="text-align:center" %)F6.46|(% style="text-align:center" %)Counter maximum|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2140 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2141 +|(% rowspan="2" style="text-align:center" %)F6.47|(% style="text-align:center" %)Counter set value|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2142 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 2153 2153 2154 2154 Set the timer time. 2155 2155 2146 +== **F7 group keyboard with display** == 2156 2156 2157 -**F7 group keyboard with display** 2158 - 2159 -|(% rowspan="2" %)F7.00|LCD keyboard parameter copy|Factory default|0 2160 -|Setting range|(% colspan="2" %)((( 2148 +|(% rowspan="2" style="text-align:center" %)F7.00|(% style="text-align:center; width:252px" %)LCD keyboard parameter copy|(% style="text-align:center; width:304px" %)Factory default|(% style="text-align:center" %)0 2149 +|(% style="text-align:center; width:252px" %)Setting range|(% colspan="2" style="width:398px" %)((( 2161 2161 0: No operation is performed 2162 2162 2163 2163 1: The function parameters of the machine are uploaded to the LCD keyboard ... ... @@ -2165,11 +2165,10 @@ 2165 2165 2: LCD keyboard function parameters download to the machine 2166 2166 ))) 2167 2167 2168 -**Note: LCD is not available.** 2157 +**✎Note: LCD is not available.** 2169 2169 2170 - 2171 -|(% rowspan="2" %)F7.01|ENT key function selection|Factory default|0 2172 -|Setting range|(% colspan="2" %)((( 2159 +|(% rowspan="2" style="text-align:center" %)F7.01|(% style="text-align:center; width:230px" %)ENT key function selection|(% style="text-align:center; width:314px" %)Factory default|(% style="text-align:center" %)0 2160 +|(% style="text-align:center; width:230px" %)Setting range|(% colspan="2" style="width:421px" %)((( 2173 2173 0: ENT is invalid 2174 2174 2175 2175 1: Switch between the command channel of the operation panel and the remote command channel (the remote command channel includes communication and terminal control) ... ... @@ -2209,8 +2209,8 @@ 2209 2209 2210 2210 Operating instructions: base for the initial menu, -C- for the debugging menu; ENT key to switch the menu, shift key to enter the corresponding menu; debugging menu displayed as CFxx.xx 2211 2211 2212 -|(% rowspan="2" %)F7.02|Keyboard STOP key range|Factory default|0011 2213 -|Setting range|(% colspan="2" %)((( 2200 +|(% rowspan="2" style="text-align:center" %)F7.02|(% style="text-align:center" %)Keyboard STOP key range|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0011 2201 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2214 2214 LED units place: Terminal control selection 2215 2215 2216 2216 0: The terminal command is invalid ... ... @@ -2228,10 +2228,10 @@ 2228 2228 LED thousands place: reserved 2229 2229 ))) 2230 2230 2231 -** Special note:** When the STOP button communication control is valid, if the machine is started by using the communication command and the machine is stopped by using the STOP button, it can be started only after the STOP command is issued before the next communication start.2219 +**✎Note:** When the STOP button communication control is valid, if the machine is started by using the communication command and the machine is stopped by using the STOP button, it can be started only after the STOP command is issued before the next communication start. 2232 2232 2233 -|(% rowspan="2" %)F7.03|Keyboard run displays parameter 1|Factory default|3420 2234 -|Setting range|(% colspan="2" %)((( 2221 +|(% rowspan="2" style="text-align:center" %)F7.03|(% style="text-align:center" %)Keyboard run displays parameter 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)3420 2222 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2235 2235 LED units place: First group display 2236 2236 2237 2237 0: Output frequency ... ... @@ -2272,8 +2272,8 @@ 2272 2272 2273 2273 LED thousands place: Fourth group display 2274 2274 ))) 2275 -|(% rowspan="2" %)F7.04|Keyboard run displays parameter 2|Factory default|0000 2276 -|Setting range|(% colspan="2" %)((( 2263 +|(% rowspan="2" style="text-align:center" %)F7.04|(% style="text-align:center" %)Keyboard run displays parameter 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0000 2264 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2277 2277 LED units place: First group display 2278 2278 2279 2279 0: No displayed ... ... @@ -2308,14 +2308,14 @@ 2308 2308 2309 2309 F: Auxiliary frequency Y is displayed 2310 2310 2311 -LED ten: second group display2299 +LED ten: Second group display 2312 2312 2313 2313 LED hundreds place: Third group display 2314 2314 2315 2315 LED thousands place: Fourth group display 2316 2316 ))) 2317 -|(% rowspan="2" %)F7.05|Keyboard stop displays parameters|Factory default|3421 2318 -|Setting range|(% colspan="2" %)((( 2305 +|(% rowspan="2" style="text-align:center" %)F7.05|(% style="text-align:center" %)Keyboard stop displays parameters|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)3421 2306 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2319 2319 LED units place: First group display 2320 2320 2321 2321 0: Output frequency ... ... @@ -2359,20 +2359,19 @@ 2359 2359 2360 2360 Control four groups of display parameters. For example, if output frequency, bus voltage, output current, and output voltage need to be displayed during operation, set the corresponding value 3420 one by one in bits to kilos. 2361 2361 2350 +|(% rowspan="2" style="text-align:center" %)F7.06|(% style="text-align:center" %)Load speed display factor|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1.000 2351 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.001 to 65.000 2362 2362 2363 -|(% rowspan="2" %)F7.06|Load speed display factor|Factory default|1.000 2364 -|Setting range|(% colspan="2" %)0.001 to 65.000 2365 - 2366 2366 Through this parameter, the output frequency of the inverter is corresponding to the load speed, load speed = output frequency /F2.04*F2.05*F7.06. 2367 2367 2368 -|(% rowspan="2" %)F7.14|High cumulative power consumption|Factory default| 2369 -|Setting range|(% colspan="2" %)((( 2355 +|(% rowspan="2" style="text-align:center" %)F7.14|(% style="text-align:center" %)High cumulative power consumption|(% style="text-align:center" %)Factory default| 2356 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2370 2370 Power consumption = F7.14*65535+F7.15 2371 2371 2372 2372 Unit: kWh 2373 2373 ))) 2374 -|(% rowspan="2" %)F7.15|Low cumulative power consumption|Factory default| 2375 -|Setting range|(% colspan="2" %)((( 2361 +|(% rowspan="2" style="text-align:center" %)F7.15|(% style="text-align:center" %)Low cumulative power consumption|(% style="text-align:center" %)Factory default| 2362 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2376 2376 Power consumption=F7.14*65535+F7.15 2377 2377 2378 2378 Unit: kWh ... ... @@ -2380,32 +2380,29 @@ 2380 2380 2381 2381 When the inverter power is large, the 16-bit power consumption parameter will overflow quickly, so two parameters are used to represent the power consumption, that is, 32 digits. 2382 2382 2383 -|(% rowspan="2" %)F7.16|Output power correction factor|Factory default|100.0% 2384 -|Setting range|(% colspan="2" %)0 to 100.0% 2370 +|(% rowspan="2" style="text-align:center" %)F7.16|(% style="text-align:center" %)Output power correction factor|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 2371 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 100.0% 2385 2385 2386 2386 Used to correct the actual output power of the motor. 2387 2387 2388 -|(% rowspan="2" %)F7.17|Power display dimension selection|Factory default|1 2389 -|Setting range|(% colspan="2" %)((( 2375 +|(% rowspan="2" style="text-align:center" %)F7.17|(% style="text-align:center" %)Power display dimension selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2376 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 2390 2390 0 to Power display percentage ~(%) 2391 2391 2392 2392 1 to Power display kilowatts (kW) 2393 2393 ))) 2394 2394 2395 - 2396 - 2397 2397 Used to select the dimension of power display D0.05, 0 is displayed in the ratio of output power to motor power, and 1 is displayed in KW. 2398 2398 2384 +== **F8 group accessibility** == 2399 2399 2400 -**F8 group accessibility** 2386 +|(% rowspan="2" style="text-align:center" %)F8.00|(% style="text-align:center" %)JOG running frequency|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00Hz 2387 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency F0.10 2388 +|(% rowspan="2" style="text-align:center" %)F8.01|(% style="text-align:center" %)JOG acceleration time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.0s 2389 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.01s to 6500.0s 2390 +|(% rowspan="2" style="text-align:center" %)F8.02|(% style="text-align:center" %)JOG deceleration time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.0s 2391 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.01s to 6500.0s 2401 2401 2402 -|(% rowspan="2" %)F8.00|JOG running frequency|Factory default|2.00Hz 2403 -|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency F0.10 2404 -|(% rowspan="2" %)F8.01|JOG acceleration time|Factory default|20.0s 2405 -|Setting range|(% colspan="2" %)0.01s to 6500.0s 2406 -|(% rowspan="2" %)F8.02|JOG deceleration time|Factory default|20.0s 2407 -|Setting range|(% colspan="2" %)0.01s to 6500.0s 2408 - 2409 2409 Define the given frequency and acceleration/deceleration time of the inverter during jog. The jog process starts and stops according to start mode 0 (F1.00, direct start) and stop mode 0 (F1.10, decelerate to stop). 2410 2410 2411 2411 Jog acceleration time refers to the time required for the inverter to accelerate from 0Hz to the maximum output frequency (F0.10). ... ... @@ -2412,39 +2412,39 @@ 2412 2412 2413 2413 Jog deceleration time refers to the time required for the inverter to decelerate from the maximum output frequency (F0.10) to 0Hz.. 2414 2414 2415 -|(% rowspan="2" %)F8.09|Emergency stop deceleration time|Factory default|Model determination 2416 -|Setting range|(% colspan="2" %)0. 01s to 6500.0s 2399 +|(% rowspan="2" style="text-align:center" %)F8.09|(% style="text-align:center" %)Emergency stop deceleration time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)Model determination 2400 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0. 01s to 6500.0s 2417 2417 2418 2418 The terminal is set to downtime in case of emergency stop. 2419 2419 2420 -|(% rowspan="2" %)F8.10|Jump frequency 1|Factory default|0.00Hz 2421 -|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency 2422 -|(% rowspan="2" %)F8.11|Jump frequency 2|Factory default|0.00Hz 2423 -|Setting range|(% colspan="2" %)0.00 Hz to Maximum frequency 2424 -|(% rowspan="2" %)F8.12|Jump frequency amplitude|Factory default|0.01Hz 2425 -|Setting range|(% colspan="2" %)0.00 to Maximum frequency 2404 +|(% rowspan="2" style="text-align:center" %)F8.10|(% style="text-align:center" %)Jump frequency 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00Hz 2405 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency 2406 +|(% rowspan="2" style="text-align:center" %)F8.11|(% style="text-align:center" %)Jump frequency 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00Hz 2407 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 Hz to Maximum frequency 2408 +|(% rowspan="2" style="text-align:center" %)F8.12|(% style="text-align:center" %)Jump frequency amplitude|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.01Hz 2409 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to Maximum frequency 2426 2426 2427 2427 When the set frequency is within the jump frequency range, the actual running frequency will run at the jump frequency boundary closer to the set frequency. By setting the jump frequency, the VFD can avoid the mechanical resonance point of the load. The inverter can be configured with two jump frequency points. This function does not work if both jump frequencies are set to 0. 2428 2428 2429 -[[image:1763107356713-939.png]] 2413 +(% style="text-align:center" %) 2414 +((( 2415 +(% style="display:inline-block" %) 2416 +[[Figure 9-8-1 Jump frequency diagram>>image:1763107356713-939.png]] 2417 +))) 2430 2430 2419 +|(% rowspan="2" style="text-align:center" %)F8.13|(% style="text-align:center" %)Reversible dead zone time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 2420 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 120.0s 2431 2431 2432 -Figure 9-8-1 Jump frequency diagram 2433 - 2434 - 2435 -|(% rowspan="2" %)F8.13|Reversible dead zone time|Factory default|0.0s 2436 -|Setting range|(% colspan="2" %)0.0 to 120.0s 2437 - 2438 2438 Set the transition time at the output zero frequency during the positive and negative transition of the inverter, as shown below: 2439 2439 2440 -[[image:1763107356720-587.png]] 2424 +(% style="text-align:center" %) 2425 +((( 2426 +(% style="display:inline-block" %) 2427 +[[Figure 9-8-2 Reverse rotation dead zone time diagram>>image:1763107356720-587.png]] 2428 +))) 2441 2441 2442 - 2443 -Figure 9-8-2 Reverse rotation dead zone time diagram 2444 - 2445 - 2446 -|(% rowspan="2" %)F8.14|The carrier frequency is adjusted with temperature|Factory default|1 2447 -|Setting range|(% colspan="2" %)((( 2430 +|(% rowspan="2" style="text-align:center" %)F8.14|(% style="text-align:center" %)The carrier frequency is adjusted with temperature|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2431 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2448 2448 0: Temperature independent 2449 2449 2450 2450 1:Temperature dependent, >75, 1.0Khz ... ... @@ -2452,8 +2452,8 @@ 2452 2452 2453 2453 Effective carrier frequency temperature adjustment means that the VFD can automatically adjust the carrier frequency according to its own temperature. Select this function to reduce the chances of VFD overheating alarm. 2454 2454 2455 -|(% rowspan="2" %)F8.15|Terminal action is preferred|Factory default|1 2456 -|Setting range|(% colspan="2" %)((( 2439 +|(% rowspan="2" style="text-align:center" %)F8.15|(% style="text-align:center" %)Terminal action is preferred|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2440 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2457 2457 0: Invalid 2458 2458 2459 2459 1: Valid ... ... @@ -2463,36 +2463,38 @@ 2463 2463 2464 2464 1: If the running command and the point-action command exist at the same time, the point-action command takes precedence. 2465 2465 2466 -|(% rowspan="2" %)F8.16|Set the cumulative power-on arrival time|Factory default|0h 2467 -|Setting range|(% colspan="2" %)0h to 65000h 2450 +|(% rowspan="2" style="text-align:center" %)F8.16|(% style="text-align:center" %)Set the cumulative power-on arrival time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0h 2451 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0h to 65000h 2468 2468 2469 2469 Pre-set the power-on time of the inverter. When the cumulative power-on time (F7.13) reaches the set power-on time, set the DO output function, and the inverter multi-function digital DO output running time arrival signal. 2470 2470 2471 -|(% rowspan="2" %)F8.17|Set the cumulative run arrival time|Factory default|65000h 2472 -|Setting range|(% colspan="2" %)0h to 65000h 2455 +|(% rowspan="2" style="text-align:center" %)F8.17|(% style="text-align:center" %)Set the cumulative run arrival time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)65000h 2456 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0h to 65000h 2473 2473 2474 2474 Pre-set the running time of the inverter. When the accumulated running time (F7.09) reaches this set running time, set the DO output function, the inverter multi-functional digital DO output running time arrival signal. 2475 2475 2476 -|(% rowspan="2" %)F8.20|Arrival time of this run|Factory default|0 2477 -|Setting range|(% colspan="2" %)0 to 65000min 2460 +|(% rowspan="2" style="text-align:center" %)F8.20|(% style="text-align:center" %)Arrival time of this run|(% style="text-align:center" %)Factory default|0 2461 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65000min 2478 2478 2479 2479 Set the current running time, shutdown clear zero. 2480 2480 2481 -|(% rowspan="2" %)F8.22|Frequency detection value (FDT1)|Factory default|50.00Hz 2482 -|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency 2483 -|(% rowspan="2" %)F8.23|Frequency Detection Lag value (FDT1)|Factory default|5.0% 2484 -|Setting range|(% colspan="2" %)0.0% to 100.0%(FDT1 Electric level) 2485 -|(% rowspan="2" %)F8.24|Frequency detection value (FDT2)|Factory default|50.00Hz 2486 -|Setting range|(% colspan="2" %)0.00Hz to Maximum frequency 2487 -|(% rowspan="2" %)F8.25|Frequency detection lag value (FDT2)|Factory default|5.0% 2488 -|Setting range|(% colspan="2" %)0.0% to 100.0%(FDT2 Electric level) 2465 +|(% rowspan="2" style="text-align:center" %)F8.22|(% style="text-align:center" %)Frequency detection value (FDT1)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)50.00Hz 2466 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency 2467 +|(% rowspan="2" style="text-align:center" %)F8.23|(% style="text-align:center" %)Frequency Detection Lag value (FDT1)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5.0% 2468 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0%(FDT1 Electric level) 2469 +|(% rowspan="2" style="text-align:center" %)F8.24|(% style="text-align:center" %)Frequency detection value (FDT2)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)50.00Hz 2470 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00Hz to Maximum frequency 2471 +|(% rowspan="2" style="text-align:center" %)F8.25|(% style="text-align:center" %)Frequency detection lag value (FDT2)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5.0% 2472 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0%(FDT2 Electric level) 2489 2489 2490 2490 Set the detection value of the output frequency and the lag value of the output action release. 2491 2491 2492 -[[image:1763107356721-853.png]] 2476 +(% style="text-align:center" %) 2477 +((( 2478 +(% style="display:inline-block" %) 2479 +[[Figure 9-8-3 Schematic diagram of FDT1 level>>image:1763107356721-853.png]] 2480 +))) 2493 2493 2494 -Figure 9-8-3 Schematic diagram of FDT1 level 2495 - 2496 2496 |(% rowspan="2" %)F8.26|Frequency reaches the detection width|Factory default|0.0% 2497 2497 |Setting range|(% colspan="2" %)0.00 to 100% Maximum frequency 2498 2498 ... ... @@ -2500,10 +2500,12 @@ 2500 2500 2501 2501 As shown below: 2502 2502 2503 -[[image:1763107356724-721.png]] 2489 +(% style="text-align:center" %) 2490 +((( 2491 +(% style="display:inline-block" %) 2492 +[[Figure 9-8-4 Schematic diagram of frequency arrival detection amplitude>>image:1763107356724-721.png]] 2493 +))) 2504 2504 2505 -Figure 9-8-4 Schematic diagram of frequency arrival detection amplitude 2506 - 2507 2507 |(% rowspan="2" %)F8.27|Arbitrary reach frequency detection value 1|Factory default|50.00Hz 2508 2508 |Setting range|(% colspan="2" %)0.00Hz to Maximum frequency 2509 2509 |(% rowspan="2" %)F8.28|Arbitrary arrival frequency detection amplitude 1|Factory default|0.0% ... ... @@ -2513,83 +2513,78 @@ 2513 2513 |(% rowspan="2" %)F8.30|Arbitrary arrival frequency detection amplitude 2|Factory default|0.0% 2514 2514 |Setting range|(% colspan="2" %)0.0% to 100.0% (Maximum frequency) 2515 2515 2516 - 2517 - 2518 2518 When the output frequency of the inverter reaches the positive and negative detection amplitude of the frequency detection value 1 and 2, the output pulse signal. 2519 2519 2520 2520 As shown below: 2521 2521 2522 -[[image:1763107356727-432.png]] 2508 +(% style="text-align:center" %) 2509 +((( 2510 +(% style="display:inline-block" %) 2511 +[[Figure 9-8-5 Schematic diagram of detection of arbitrary arrival frequency>>image:1763107356727-432.png]] 2512 +))) 2523 2523 2524 -Figure 9-8-5 Schematic diagram of detection of arbitrary arrival frequency 2514 +|(% rowspan="2" style="text-align:center" %)F8.31|(% style="text-align:center" %)Arbitrary arrival current 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 2515 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0%-300.0% (Rated current of motor) 2516 +|(% rowspan="2" style="text-align:center" %)F8.32|(% style="text-align:center" %)Arbitrary arrival current 1 width|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 2517 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0%-300.0% (Rated current of motor) 2518 +|(% rowspan="2" style="text-align:center" %)F8.33|(% style="text-align:center" %)Arbitrary arrival current 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 2519 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 300.0%(Rated current of motor) 2520 +|(% rowspan="2" style="text-align:center" %)F8.34|(% style="text-align:center" %)Arbitrary arrival current 2 width|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 2521 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 300.0%(Rated current of motor) 2525 2525 2526 - 2527 -|(% rowspan="2" %)F8.31|Arbitrary arrival current 1|Factory default|100.0% 2528 -|Setting range|(% colspan="2" %)0.0%-300.0% (Rated current of motor) 2529 -|(% rowspan="2" %)F8.32|Arbitrary arrival current 1 width|Factory default|0.0% 2530 -|Setting range|(% colspan="2" %)0.0%-300.0% (Rated current of motor) 2531 -|(% rowspan="2" %)F8.33|Arbitrary arrival current 2|Factory default|100.0% 2532 -|Setting range|(% colspan="2" %)0.0% to 300.0%(Rated current of motor) 2533 -|(% rowspan="2" %)F8.34|Arbitrary arrival current 2 width|Factory default|0.0% 2534 -|Setting range|(% colspan="2" %)0.0% to 300.0%(Rated current of motor) 2535 - 2536 - 2537 - 2538 2538 When the output current of the inverter reaches any positive or negative detection width of current 1 and 2, output pulse signal. 2539 2539 2540 2540 As shown below: 2541 2541 2527 +(% style="text-align:center" %) 2528 +((( 2529 +(% style="display:inline-block" %) 2530 +[[Figure. 9-8-6 Schematic diagram of detection of arbitrary arrival frequency>>image:1763107356731-567.png]] 2531 +))) 2542 2542 2543 -[[image:1763107356731-567.png]] 2533 +|(% rowspan="2" style="text-align:center" %)F8.35|(% style="text-align:center" %)Zero current detection value|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5.0% 2534 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 300.0% (Rated current of motor) 2535 +|(% rowspan="2" style="text-align:center" %)F8.36|(% style="text-align:center" %)Zero current detection delay time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0s 2536 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 600.00s 2544 2544 2545 -Figure. 9-8-6 Schematic diagram of detection of arbitrary arrival frequency 2546 - 2547 -|(% rowspan="2" %)F8.35|Zero current detection value|Factory default|5.0% 2548 -|Setting range|(% colspan="2" %)0.0% to 300.0% (Rated current of motor) 2549 -|(% rowspan="2" %)F8.36|Zero current detection delay time|Factory default|0s 2550 -|Setting range|(% colspan="2" %)0 to 600.00s 2551 - 2552 -Figure 9-8-7 Schematic diagram of zero current detection 2553 - 2554 2554 When the output current of the inverter is less than or equal to the zero current detection level and the duration exceeds the zero current detection delay time, the output pulse 2555 2555 2556 2556 Rush the signal. As shown below: 2557 2557 2542 +(% style="text-align:center" %) 2543 +((( 2544 +(% style="display:inline-block" %) 2545 +[[Figure 9-8-7 Schematic diagram of zero current detection>>image:1763358952427-755.png]] 2546 +))) 2558 2558 2559 -| 2560 -| |[[image:1763107356732-988.png]] 2548 +|(% rowspan="2" style="text-align:center" %)F8.37|(% style="text-align:center" %)Software overflow point (DO output)|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)200.0% 2549 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 300.0% (Rated current of VFD) 2550 +|(% rowspan="2" style="text-align:center" %)F8.38|(% style="text-align:center" %)Software over current detection delay time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0s 2551 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 600.00s 2561 2561 2562 - 2563 - 2564 -|(% rowspan="2" %)F8.37|Software overflow point (DO output)|Factory default|200.0% 2565 -|Setting range|(% colspan="2" %)0.0% to 300.0% (Rated current of VFD) 2566 -|(% rowspan="2" %)F8.38|Software over current detection delay time|Factory default|0s 2567 -|Setting range|(% colspan="2" %)0 to 600.00s 2568 - 2569 - 2570 - 2571 2571 When the output current of the inverter is greater than or equal to the software over current point and the duration exceeds the software over current point detection delay time, the output pulse 2572 2572 2573 2573 Rush the signal. As shown below: 2574 2574 2557 +(% style="text-align:center" %) 2558 +((( 2559 +(% style="display:inline-block" %) 2560 +[[Figure 9-8-8 Schematic diagram of software overflow point detection>>image:1763107356734-922.png]] 2561 +))) 2575 2575 2576 -| 2577 -| |[[image:1763107356734-922.png]] 2563 +== **F9 group process control PID function** == 2578 2578 2579 -Figure 9-8-8 Schematic diagram of software overflow point detection 2580 - 2581 - 2582 -**F9 group process control PID function** 2583 - 2584 2584 PID control is a common method used for process control. By proportional, integral and differential operations on the difference between the feedback signal of the controlled quantity and the target quantity signal, the output frequency of the inverter is adjusted to form a negative feedback system, so that the controlled quantity is stable on the target quantity. Suitable for flow control, pressure control, temperature control and other process control. The basic control block diagram is as follows: 2585 2585 2586 2586 2587 -[[image:1763107356736-468.png]] 2568 +(% style="text-align:center" %) 2569 +((( 2570 +(% style="display:inline-block" %) 2571 +[[Figure 9-9-1 Process PID schematic diagram>>image:1763107356736-468.png]] 2572 +))) 2588 2588 2589 -Figure 9-9-1 Process PID schematic diagram 2590 - 2591 -|(% rowspan="2" %)F9.00|PID given source|Factory default|0 2592 -|Setting range|(% colspan="2" %)((( 2574 +|(% rowspan="2" style="text-align:center" %)F9.00|(% style="text-align:center" %)PID given source|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2575 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2593 2593 0: Keyboard number PID is set to F9.01 2594 2594 2595 2595 1: AI1 ... ... @@ -2609,14 +2609,13 @@ 2609 2609 2610 2610 When the frequency source is selected PID, that is, F0.03 or F0.04 is selected 8, this set of functions works. (See function code F0.03-F0.04.) This parameter determines the target amount of the process PID for a given channel. The set target quantity of process PID is relative value, and 100% of the set value corresponds to 100% of the feedback signal of the controlled system. The range of the PID (F9.04) is not required, because the system calculates relative values (0 to 100%) regardless of the range set. However, if the PID range is set, the actual value of the PID given and feedback corresponding to the signal can be visually observed through the keyboard display parameters. 2611 2611 2612 -|(% rowspan="2" %)F9.01|PID Value setting|Factory default|50.0% 2613 -|Setting range|(% colspan="2" %)0.00 to 100.0% 2595 +|(% rowspan="2" style="text-align:center" %)F9.01|(% style="text-align:center" %)PID Value setting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)50.0% 2596 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 100.0% 2614 2614 2615 2615 When F9.00=0 is selected, the target source is the keyboard given. This parameter needs to be set. The reference value of this parameter is the feedback amount of the system. 2616 2616 2617 - 2618 -|(% rowspan="2" %)F9.02|PID feedback source|Factory default|0 2619 -|Setting range|(% colspan="2" %)((( 2600 +|(% rowspan="2" style="text-align:center" %)F9.02|(% style="text-align:center" %)PID feedback source|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2601 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2620 2620 0: AI1 2621 2621 2622 2622 1: AI2 ... ... @@ -2640,14 +2640,6 @@ 2640 2640 2641 2641 This parameter is used to select the PID feedback channel. 2642 2642 2643 - 2644 - 2645 - 2646 - 2647 - 2648 - 2649 - 2650 - 2651 2651 |(% rowspan="2" %)F9.03|PID control characteristic|Factory default|0 2652 2652 |Setting range|(% colspan="2" %)((( 2653 2653 LED ones digit: Feedback feature selection ... ... @@ -2693,14 +2693,14 @@ 2693 2693 2694 2694 Center alignment: Error correction. 2695 2695 2696 -|(% rowspan="2" %)F9.04|PID given feedback range|Factory default|100.0 2697 -|Setting range|(% colspan="2" %)0 to 100.0 2698 -|(% rowspan="2" %)F9.05|Proportional gain P1|Factory default|20.00 2699 -|Setting range|(% colspan="2" %)0.00 to 1000.00 2700 -|(% rowspan="2" %)F9.06|Integration time I1|Factory default|2.00s 2701 -|Setting range|(% colspan="2" %)0.00 to 10.00s 2702 -|(% rowspan="2" %)F9.07|D1derivative time D1|Factory default|0.00s 2703 -|Setting range|(% colspan="2" %)0.00 to 10.00s 2670 +|(% rowspan="2" style="text-align:center" %)F9.04|(% style="text-align:center" %)PID given feedback range|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0 2671 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 100.0 2672 +|(% rowspan="2" style="text-align:center" %)F9.05|(% style="text-align:center" %)Proportional gain P1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.00 2673 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 1000.00 2674 +|(% rowspan="2" style="text-align:center" %)F9.06|(% style="text-align:center" %)Integration time I1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00s 2675 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 10.00s 2676 +|(% rowspan="2" style="text-align:center" %)F9.07|(% style="text-align:center" %)D1derivative time D1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00s 2677 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 10.00s 2704 2704 2705 2705 Proportional gain P1: Determines the adjustment intensity of the entire PID regulator, the greater the P, the greater the adjustment intensity. The parameter 100 indicates that when the deviation between the PID feedback quantity and the feed quantity is 100%, the PID: regulator's adjustment amplitude to the output frequency instruction is Maximum frequency (ignoring the integral and differential effects). 2706 2706 ... ... @@ -2708,49 +2708,40 @@ 2708 2708 2709 2709 Differential time D1: Determines the intensity with which the PID regulator adjusts the amount of PID feedback and the rate of change of the given amount of deviation. The differential time means that if the feedback quantity changes 100% in this time, the adjustment amount of the differential regulator is Maximum frequency (F0.10) (ignoring the proportional action and integral action). The longer the differential time, the greater the adjustment intensity. 2710 2710 2711 -|(% rowspan="2" %)F9.08|Reverse cut-off frequency|Factory default|0.00Hz 2712 -|Setting range|(% colspan="2" %)0.00 to Maximum frequency F0.10 2713 -|(% rowspan="2" %)F9.09|PID deviation limit|Factory default|0.0% 2714 -|Setting range|(% colspan="2" %)0. 0% to 100.0% 2685 +|(% rowspan="2" style="text-align:center" %)F9.08|(% style="text-align:center" %)Reverse cut-off frequency|(% style="text-align:center" %)Factory default|0.00Hz 2686 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to Maximum frequency F0.10 2687 +|(% rowspan="2" style="text-align:center" %)F9.09|(% style="text-align:center" %)PID deviation limit|(% style="text-align:center" %)Factory default|0.0% 2688 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0. 0% to 100.0% 2715 2715 2716 - 2717 - 2718 2718 Deviation limit: When the PID feedback deviation is within this range, the PID stops adjusting. 2719 2719 2720 -|(% rowspan="2" %)F9.10|PID differential limiting|Factory default|0.10% 2721 -|Setting range|(% colspan="2" %)0.00% to 100.00% 2722 -|(% rowspan="2" %)F9.11|PID given change time|Factory default|0.00s 2723 -|Setting range|(% colspan="2" %)0.00s to 100.00s 2692 +|(% rowspan="2" style="text-align:center" %)F9.10|(% style="text-align:center" %)PID differential limiting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.10% 2693 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00% to 100.00% 2694 +|(% rowspan="2" style="text-align:center" %)F9.11|(% style="text-align:center" %)PID given change time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00s 2695 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00s to 100.00s 2724 2724 2725 - 2726 - 2727 2727 The given PID change time refers to the time required for the actual PID value to change from 0.0% to 100.0%. 2728 2728 2729 2729 When the PID set changes, the actual value of the PID set does not follow the immediate response. And according to the given change time linear change, prevent a given mutation. 2730 2730 2731 -|(% rowspan="2" %)F9.12|PID feedback filtering time|Factory default|0.00s 2732 -|Setting range|(% colspan="2" %)0.00s to 60.00s 2733 -|(% rowspan="2" %)F9.13|PID output filtering time|Factory default|0.00s 2734 -|Setting range|(% colspan="2" %)0.00s to 60.00s 2701 +|(% rowspan="2" style="text-align:center" %)F9.12|(% style="text-align:center" %)PID feedback filtering time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00s 2702 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00s to 60.00s 2703 +|(% rowspan="2" style="text-align:center" %)F9.13|(% style="text-align:center" %)PID output filtering time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00s 2704 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00s to 60.00s 2735 2735 2736 - 2737 - 2738 2738 The PID feedback and output values are filtered to eliminate abrupt changes. 2739 2739 2708 +|(% rowspan="2" style="text-align:center" %)F9.14|(% style="text-align:center" %)Proportional gain P2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.0 2709 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 100.0 2710 +|(% rowspan="2" style="text-align:center" %)F9.15|(% style="text-align:center" %)Integration time I2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00s 2711 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.01s to 10.00s 2712 +|(% rowspan="2" style="text-align:center" %)F9.16|(% style="text-align:center" %)Differential time D2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.000s 2713 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 10.000 2740 2740 2741 -|(% rowspan="2" %)F9.14|Proportional gain P2|Factory default|20.0 2742 -|Setting range|(% colspan="2" %)0.0 to 100.0 2743 -|(% rowspan="2" %)F9.15|Integration time I2|Factory default|2.00s 2744 -|Setting range|(% colspan="2" %)0.01s to 10.00s 2745 -|(% rowspan="2" %)F9.16|Differential time D2|Factory default|0.000s 2746 -|Setting range|(% colspan="2" %)0.00 to 10.000 2747 - 2748 - 2749 - 2750 2750 The setting is similar to F9.05, F9.06, and F9.07. For details about how to change the PID parameters, see F9.18. 2751 2751 2752 -|(% rowspan="2" %)F9.17|PID parameter switching condition|Factory default|0 2753 -|Setting range|(% colspan="2" %)((( 2717 +|(% rowspan="2" style="text-align:center" %)F9.17|(% style="text-align:center" %)PID parameter switching condition|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2718 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)((( 2754 2754 0: No switching 2755 2755 2756 2756 1: Terminal switch ... ... @@ -2757,10 +2757,10 @@ 2757 2757 2758 2758 2: Automatically switch according to deviation 2759 2759 ))) 2760 -|(% rowspan="2" %)F9.18|PID parameter switching deviation 1|Factory default|20.0% 2761 -|Setting range|(% colspan="2" %)0.0% to F9.19 2762 -|(% rowspan="2" %)F9.19|PID parameter switching deviation 2|Factory default|80.0% 2763 -|Setting range|(% colspan="2" %)F9.18 to 100.0% 2725 +|(% rowspan="2" style="text-align:center" %)F9.18|(% style="text-align:center" %)PID parameter switching deviation 1|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.0% 2726 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to F9.19 2727 +|(% rowspan="2" style="text-align:center" %)F9.19|(% style="text-align:center" %)PID parameter switching deviation 2|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)80.0% 2728 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)F9.18 to 100.0% 2764 2764 2765 2765 In some applications, a single set of PID parameters may not be sufficient for the entire operation. Multiple groups of PID parameters may need to be switched. 2766 2766 ... ... @@ -2770,16 +2770,15 @@ 2770 2770 2771 2771 2: Automatic switching according to the deviation. When the deviation between the given and feedback is less than PID parameter switching deviation 1 (F9.19), F9.05, F9.06 and F9.07 are used as PID adjustment parameters. When the deviation between given and feedback is greater than PID switching deviation 2 (F9.20), F9.15, F9.16 and F9.17 are used as PID adjustment parameters. The PID parameters in the deviation section between switching deviation 1 and switching deviation 2 are linearly switched between the two groups of PID parameters. 2772 2772 2773 -|(% rowspan="2" %)F9.20|PID initial frequency value|Factory default|0% 2774 -|Setting range|(% colspan="2" %)0.0% to 100.0% 2775 -|(% rowspan="2" %)F9.21|PID initial retention time|Factory default|0.0s 2776 -|Setting range|(% colspan="2" %)0.00s to 650.0 0s2738 +|(% rowspan="2" style="text-align:center" %)F9.20|(% style="text-align:center" %)PID initial frequency value|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0% 2739 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0% 2740 +|(% rowspan="2" style="text-align:center" %)F9.21|(% style="text-align:center" %)PID initial retention time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 2741 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00s to 6500.0s 2777 2777 2778 2778 During PID operation, the inverter first sets the output operation with the initial PID value (F9.20) and the duration is F9.21 (PID initial value holding time), and then starts the normal PID adjustment. 2779 2779 2780 - 2781 -|(% rowspan="2" %)F9.23|Feedback wire break action selection|Factory default|0 2782 -|Setting range|(% colspan="2" %)((( 2745 +|(% rowspan="2" style="text-align:center" %)F9.23|(% style="text-align:center" %)Feedback wire break action selection|(% style="text-align:center" %)Factory default|0 2746 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)((( 2783 2783 0: PID continues to run and no fault is reported 2784 2784 2785 2785 1: Stop and report fault (manual reset) ... ... @@ -2790,17 +2790,15 @@ 2790 2790 2791 2791 4: Stop and report fault (automatic reset) 2792 2792 ))) 2793 -|(% rowspan="2" %)F9.24|Wire break alarm upper limit|Factory default|100.0% 2794 -|Setting range|(% colspan="2" %)F9.25 to 100.0% 2795 -|(% rowspan="2" %)F9.25|Line break alarm lower limit|Factory default|0.0% 2796 -|Setting range|(% colspan="2" %)0 to F9.24% 2797 -|(% rowspan="2" %)F9.26|Feedback break detection time|Factory default|0.0s 2798 -|Setting range|(% colspan="2" %)0.0s to 120.0s 2757 +|(% rowspan="2" style="text-align:center" %)F9.24|(% style="text-align:center" %)Wire break alarm upper limit|(% style="text-align:center" %)Factory default|100.0% 2758 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)F9.25 to 100.0% 2759 +|(% rowspan="2" style="text-align:center" %)F9.25|(% style="text-align:center" %)Line break alarm lower limit|(% style="text-align:center" %)Factory default|0.0% 2760 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to F9.24% 2761 +|(% rowspan="2" style="text-align:center" %)F9.26|(% style="text-align:center" %)Feedback break detection time|(% style="text-align:center" %)Factory default|0.0s 2762 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s to 120.0s 2799 2799 2764 +Determine whether the PID feedback is lost. If the PID feedback is lower than the disconnection alarm lower limit (F9.25) or higher than the disconnection alarm upper limit (F9.24) for a duration reaching F9.26 (feedback loss detection time), the inverter will report a fault and operate according to the F9.29 setting. 2800 2800 2801 - 2802 -3 The upper limit (F9.24) duration reaches F9.26 (feedback loss detection time), the inverter reports a fault and runs according to F9.29 setting. 2803 - 2804 2804 |(% rowspan="2" %)F9.27|PID stop operation|Factory default|0 2805 2805 |Setting range|(% colspan="2" %)((( 2806 2806 0: Disable calculation on shutdown ... ... @@ -2818,26 +2818,27 @@ 2818 2818 2819 2819 1: The inverter runs with sleep PID control, and the sleep function is enabled. 2820 2820 2821 -|(% rowspan="2" %)F9.29|PID sleep threshold|Factory default|60.0% 2822 -|Setting range|(% colspan="2" %)0.0% to 100.0% 2823 -|(% rowspan="2" %)F9.30|PID sleep delay|Factory default|3.0s 2824 -|Setting range|(% colspan="2" %)0.0 to 3600.0s 2825 -|(% rowspan="2" %)F9.31|PID wake-up threshold|Factory default|20.0% 2826 -|Setting range|(% colspan="2" %)0.0% to 100.0% 2827 -|(% rowspan="2" %)F9.32|PID wake up delay|Factory default|3.0s 2828 -|Setting range|(% colspan="2" %)0.0 to 3600.0s 2783 +|(% rowspan="2" style="text-align:center" %)F9.29|(% style="text-align:center" %)PID sleep threshold|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)60.0% 2784 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0% 2785 +|(% rowspan="2" style="text-align:center" %)F9.30|(% style="text-align:center" %)PID sleep delay|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)3.0s 2786 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 3600.0s 2787 +|(% rowspan="2" style="text-align:center" %)F9.31|(% style="text-align:center" %)PID wake-up threshold|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)20.0% 2788 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0% 2789 +|(% rowspan="2" style="text-align:center" %)F9.32|(% style="text-align:center" %)PID wake up delay|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)3.0s 2790 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 3600.0s 2829 2829 2830 2830 When selecting the sleep PID, if the feedback is higher than the sleep threshold set by F9.29 and the running frequency is less than or equal to the sleep frequency set by F9.33, the VFD starts the sleep timing. After the sleep delay time set by F9.30, if the feedback quantity is higher than the set quantity set by F9.29 and the running frequency is less than or equal to the sleep frequency set by F9.33, Then the PID stops running and the inverter enters sleep state. If the feedback is lower than the setting of F9.31 wake-up threshold, the VFD starts the wake-up timing. After the time set by F9.32 wake-up delay, if the feedback is still lower than the setting of F9.31 wake-up threshold, the wake-up is successful and PID control is performed. Refer to Figure 9-9-2 below to understand the above parameter relationships. 2831 2831 2832 -[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml14320\wps10.png]] 2794 +(% style="text-align:center" %) 2795 +((( 2796 +(% style="display:inline-block" %) 2797 +[[Figure 9-9-2 Schematic diagram of PID sleep and wake time sequence>>image:1763360417842-953.png]] 2798 +))) 2833 2833 2834 -Figure 9-9-2 Schematic diagram of PID sleep and wake time sequence 2835 - 2836 - 2837 -|(% rowspan="2" %)F9.33|Dormancy detection frequency|Factory default|25.00Hz 2838 -|Setting range|(% colspan="2" %)0 to Upper limit frequency F0.12 2839 -|(% rowspan="2" %)F9.34|Minimum output|Factory default|0 2840 -|Setting range|(% colspan="2" %)((( 2800 +|(% rowspan="2" style="text-align:center" %)F9.33|(% style="text-align:center" %)Dormancy detection frequency|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)25.00Hz 2801 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to upper limit frequency F0.12 2802 +|(% rowspan="2" style="text-align:center" %)F9.34|(% style="text-align:center" %)Minimum output|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2803 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)((( 2841 2841 0: F0.14 (Lower limit frequency) 2842 2842 2843 2843 1: 0Hz ... ... @@ -2845,25 +2845,23 @@ 2845 2845 2846 2846 Sleep detection frequency: Frequency at which the system determines whether the sleep condition is met. 2847 2847 2848 -|(% rowspan="2" %)F9.35|Maximum forward deviation of two outputs|Factory default|1.00%. 2849 -|Setting range|(% colspan="2" %)0.00% to 100.00% 2850 -|(% rowspan="2" %)F9.36|Maximum reverse deviation of two outputs|Factory default|1.00% 2851 -|Setting range|(% colspan="2" %)0.00% to 100.00% 2811 +|(% rowspan="2" style="text-align:center" %)F9.35|(% style="text-align:center" %)Maximum forward deviation of two outputs|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1.00%. 2812 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00% to 100.00% 2813 +|(% rowspan="2" style="text-align:center" %)F9.36|(% style="text-align:center" %)Maximum reverse deviation of two outputs|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1.00% 2814 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00% to 100.00% 2852 2852 2853 - 2854 - 2855 2855 This function code is used to limit the difference between the PID output two beats (2ms/ beat), thereby suppress the PID output changes too fast. F9.23 and F9.24 correspond to the maximum output deviation for forward and reverse rotation respectively. 2856 2856 2857 -|(% rowspan="2" %)F9.38|PID preset switchover condition selection|Factory default|0 2858 -|Setting range|(% colspan="2" %)((( 2818 +|(% rowspan="2" style="text-align:center" %)F9.38|(% style="text-align:center" %)PID preset switchover condition selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 2819 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)((( 2859 2859 0: Time 2860 2860 2861 2861 1: Switch according to AI1 feedback value 2862 2862 ))) 2863 -|(% rowspan="2" %)F9.39|PID AI feedback switching minimum|Factory default|45.0% 2864 -|Setting range|(% colspan="2" %)0.0 to F8.18 2865 -|(% rowspan="2" %)F9.40|PID AI feedback switching maximum|Factory default|55.0% 2866 -|Setting range|(% colspan="2" %)F8.17 to 100.0% 2824 +|(% rowspan="2" style="text-align:center" %)F9.39|(% style="text-align:center" %)PID AI feedback switching minimum|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)45.0% 2825 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to F8.18 2826 +|(% rowspan="2" style="text-align:center" %)F9.40|(% style="text-align:center" %)PID AI feedback switching maximum|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)55.0% 2827 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)F8.17 to 100.0% 2867 2867 2868 2868 PID preset switching condition selection: Switch from preset output frequency (F9.20) to PID given. 2869 2869 ... ... @@ -2871,10 +2871,10 @@ 2871 2871 2872 2872 1: Switch when the feedback value is greater than or equal to F9.23 and less than or equal to F9.24. 2873 2873 2874 -**FA group failure and protection** 2835 +== **FA group failure and protection** == 2875 2875 2876 -|(% rowspan="2" %)FA.00|Motor overload protection selection|Factory default|1 2877 -|Setting range|(% colspan="2" %)((( 2837 +|(% rowspan="2" style="text-align:center" %)FA.00|(% style="text-align:center" %)Motor overload protection selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2838 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2878 2878 0: Off 2879 2879 2880 2880 1: On ... ... @@ -2884,18 +2884,18 @@ 2884 2884 2885 2885 Select 1: At this time, the inverter has overload protection function for the motor. See FA.01 for protection values. 2886 2886 2887 -|(% rowspan="2" %)FA.01|Motor overload protection factor|Factory default|100.0% 2888 -|Setting range|(% colspan="2" %)0.0 to 250.0% 2848 +|(% rowspan="2" style="text-align:center" %)FA.01|(% style="text-align:center" %)Motor overload protection factor|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)100.0% 2849 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 250.0% 2889 2889 2890 2890 Motor overload protection is inverse time curve; 220% x (FA.01) x rated motor current for 1 minute, 150% x (FA.01) x rated motor current for 60 minutes. 2891 2891 2892 -|(% rowspan="2" %)FA.02|Motor overload warning factor|Factory default|80.0% 2893 -|Setting range|(% colspan="2" %)20.0 to 250.0% 2853 +|(% rowspan="2" style="text-align:center" %)FA.02|(% style="text-align:center" %)Motor overload warning factor|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)80.0% 2854 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)20.0 to 250.0% 2894 2894 2895 2895 The reference for this value is the overload current of the motor. When the inverter detects that the output current reaches (FA.02) x the motor overload current and continues for the specified time in the inverse time curve, the forecast alarm is output from the DO or relay. 2896 2896 2897 -|(% rowspan="2" %)FA.03|Over voltage stall/over loss rate control options|Factory default|1111 2898 -|Setting range|(% colspan="2" %)((( 2858 +|(% rowspan="2" style="text-align:center" %)FA.03|(% style="text-align:center; width:361px" %)Over voltage stall/over loss rate control options|(% style="text-align:center; width:200px" %)Factory default|(% style="text-align:center" %)1111 2859 +|(% style="text-align:center; width:361px" %)Setting range|(% colspan="2" style="width:331px" %)((( 2899 2899 0: Off 2900 2900 2901 2901 1: On ... ... @@ -2925,30 +2925,26 @@ 2925 2925 2926 2926 This bit is used to set how the frequency increases when over current suppression is withdrawn. When set to 0, the frequency is accelerated according to the acceleration time; When set to 1, the frequency is controlled by the current, so as the current decreases, the frequency will rise rapidly. 2927 2927 2889 +|(% rowspan="2" style="text-align:center" %)FA.04|(% style="text-align:center" %)Over pressure suppression point|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)Model-based setting 2890 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)110% to 150% 2891 +|(% rowspan="2" style="text-align:center" %)FA.05|(% style="text-align:center" %)Udc control voltage loop gain|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00 2892 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 50.00 2893 +|(% rowspan="2" style="text-align:center" %)FA.06|(% style="text-align:center" %)Udc control current loop gain|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2.00 2894 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 50.00 2928 2928 2929 -|(% rowspan="2" %)FA.04|Over pressure suppression point|Factory default|Model-based setting 2930 -|Setting range|(% colspan="2" %)110% to 150% 2931 -|(% rowspan="2" %)FA.05|Udc control voltage loop gain|Factory default|2.00 2932 -|Setting range|(% colspan="2" %)0.00 to 50.00 2933 -|(% rowspan="2" %)FA.06|Udc control current loop gain|Factory default|2.00 2934 -|Setting range|(% colspan="2" %)0.00 to 50.00 2935 - 2936 2936 When the bus voltage exceeds FA.04× rated bus voltage during the operation of the VFD, the VFD will automatically adjust the operating frequency to suppress the bus voltage rise, so as to ensure that the VFD will not cause over voltage protection due to the high bus voltage. FA.05 and FA.06 are the voltage loop gain and current loop gain when the bus voltage is regulated, respectively. Instantaneous stop of the voltage loop and current loop gain is also the reference number. 2937 2937 2898 +|(% rowspan="2" style="text-align:center" %)FA.07|(% style="text-align:center" %)Over current suppression point|(% style="text-align:center" %)Factory default|150% 2899 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)50% to 200% 2900 +|(% rowspan="2" style="text-align:center" %)FA.08|(% style="text-align:center" %)Over current suppression gain|(% style="text-align:center" %)Factory default|2.00 2901 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 50.00 2902 +|(% rowspan="2" style="text-align:center" %)FA.09|(% style="text-align:center" %)Over current suppression integral|(% style="text-align:center" %)Factory default|4.00 2903 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 50.00 2938 2938 2939 -|(% rowspan="2" %)FA.07|Over current suppression point|Factory default|150% 2940 -|Setting range|(% colspan="2" %)50% to 200% 2941 -|(% rowspan="2" %)FA.08|Over current suppression gain|Factory default|2.00 2942 -|Setting range|(% colspan="2" %)0.00 to 50.00 2943 -|(% rowspan="2" %)FA.09|Over current suppression integral|Factory default|4.00 2944 -|Setting range|(% colspan="2" %)0.00 to 50.00 2945 - 2946 - 2947 - 2948 2948 When controlling the motor, the motor current increases with the increase of load, and the over current suppression gain function limits the maximum current of the motor. When the current reaches the rated current of FA.07* inverter, the output frequency automatically decreases to limit the motor current not exceeding the current set by FA.07; FA.08 and FA.09 are over current suppression controller parameters. Adjusting these two parameters can improve and optimize the over current suppression effect. 2949 2949 2950 -|(% rowspan="2" %)FA.10|Power-on short-circuit detection to the ground|Factory default|1 2951 -|Setting range|(% colspan="2" %)((( 2907 +|(% rowspan="2" style="text-align:center" %)FA.10|(% style="text-align:center" %)Power-on short-circuit detection to the ground|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2908 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 2952 2952 0: Invalid 2953 2953 2954 2954 1: Valid ... ... @@ -2956,8 +2956,8 @@ 2956 2956 2957 2957 The inverter can be selected to detect whether the motor has a ground protection short circuit fault when it is powered on. If this function is effective, the inverter is output for a short time at the moment of power-on. 2958 2958 2959 -|(% rowspan="2" %)FA.11|Input phase loss protection|Factory default|1 2960 -|Setting range|(% colspan="2" %)((( 2916 +|(% rowspan="2" style="text-align:center" %)FA.11|(% style="text-align:center" %)Input phase loss protection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2917 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 2961 2961 0: Off 2962 2962 2963 2963 1: On ... ... @@ -2965,8 +2965,8 @@ 2965 2965 2966 2966 Select whether to protect against input phase loss. 2967 2967 2968 -|(% rowspan="2" %)FA.12|Output phase loss protection|Factory default|1 2969 -|Setting range|(% colspan="2" %)((( 2925 +|(% rowspan="2" style="text-align:center" %)FA.12|(% style="text-align:center" %)Output phase loss protection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 2926 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)((( 2970 2970 0: Off 2971 2971 2972 2972 1: On ... ... @@ -2974,13 +2974,13 @@ 2974 2974 2975 2975 Select whether to protect output phase loss. 2976 2976 2977 -|(% rowspan="2" %)FA.13|Input phase loss protection software detection level|Factory default|15.0% 2978 -|Setting range|(% colspan="2" %)0.0 to 999.9% 2934 +|(% rowspan="2" style="text-align:center" %)FA.13|(% style="text-align:center" %)Input phase loss protection software detection level|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)15.0% 2935 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 to 999.9% 2979 2979 2980 2980 The input missing phase is judged by calculating the fluctuation of bus voltage. This parameter is used to set the threshold of bus voltage fluctuation when the input phase is out. Turning down can increase the sensitive zero of the input phase out, and turning up can reduce the probability of false positive of the input phase out. 2981 2981 2982 -|(% rowspan="2" %)FA.14|PWM Parameter setting|Factory default|0010 2983 -|Setting range|(% colspan="2" %)((( 2939 +|(% rowspan="2" style="text-align:center" %)FA.14|(% style="text-align:center" %)PWM Parameter setting|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0010 2940 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 2984 2984 LED units place: Turn on voltage prediction compensation 2985 2985 2986 2986 LED tens place: PWM update mode ... ... @@ -2989,7 +2989,7 @@ 2989 2989 2990 2990 1: Double sample and double update 2991 2991 2992 -LED hundreds place: random carrier mode2949 +LED hundreds place: Random carrier mode 2993 2993 2994 2994 0: Random carrier 2995 2995 ... ... @@ -3002,14 +3002,14 @@ 3002 3002 3003 3003 LED tens place: PWM update mode. 3004 3004 3005 -0: single sample update. 1: Double sample and double update.2962 +0: Single sample update. 1: Double sample and double update. 3006 3006 3007 -LED hundreds place: random carrier mode.2964 +LED hundreds place: Random carrier mode. 3008 3008 3009 3009 0: Random PWM carrier frequency. 1: Random 0 vector. 3010 3010 3011 -|(% rowspan="2" %)FA.15|Hardware current and voltage protection|Factory default|0011 3012 -|Setting range|(% colspan="2" %)((( 2968 +|(% rowspan="2" style="text-align:center" %)FA.15|(% style="text-align:center" %)Hardware current and voltage protection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0011 2969 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3013 3013 LED units place: Current limiting (CBC) 3014 3014 3015 3015 0: Off ... ... @@ -3031,7 +3031,7 @@ 3031 3031 3032 3032 0: Disable CBC current limiting 1: Enable CBC current limiting 3033 3033 3034 -LED tens place: reserved.2991 +LED tens place: Reserved. 3035 3035 3036 3036 LED hundreds place: FAU filtering time. 3037 3037 ... ... @@ -3041,33 +3041,30 @@ 3041 3041 3042 3042 The TZ signal is an over current signal. This parameter is used to set the filtering time of the TZ signal. 3043 3043 3044 -|(% rowspan="2" %)FA.16|CBC protection point|Factory default|200% 3045 -|Setting range|(% colspan="2" %)100 to 220% 3046 -|(% rowspan="2" %)FA.17|CBC overload protection time|Factory default|500ms 3047 -|Setting range|(% colspan="2" %)1 to 5000ms 3001 +|(% rowspan="2" style="text-align:center" %)FA.16|(% style="text-align:center" %)CBC protection point|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)200% 3002 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)100 to 220% 3003 +|(% rowspan="2" style="text-align:center" %)FA.17|(% style="text-align:center" %)CBC overload protection time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)500ms 3004 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)1 to 5000ms 3048 3048 3049 - 3050 - 3051 3051 When the motor current is higher than the rated current of FA.16*VFD, the per-wave current limiting starts. If the per-wave current limiting duration exceeds the time set in FA.17, the VFD reports Err. This parameter is used to set the per-wave current limiting current and fault response time. 3052 3052 3053 -|(% rowspan="2" %)FA.18|Under voltage point setting|Factory default|100.0% 3054 -|Setting range|(% colspan="2" %) 100to220%3008 +|(% rowspan="2" style="text-align:center" %)FA.18|(% style="text-align:center" %)Under voltage point setting|(% style="text-align:center" %)Factory default|100.0% 3009 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)40.0% to 100.0% 3055 3055 3056 3056 Adjusting this parameter can adjust the voltage point of the VFD reporting the under voltage fault (Err09), 100.0% corresponds to 350V. 3057 3057 3058 -|(% rowspan="2" %)FA.20|Times of self-recovery|Factory default|0 3059 -|Setting range|(% colspan="2" %)0 to 5 3013 +|(% rowspan="2" style="text-align:center" %)FA.20|(% style="text-align:center" %)Times of self-recovery|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3014 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 5 3060 3060 3061 3061 When the inverter selects fault automatic reset, it is used to set the number of times that can be automatically reset. If the value exceeds this value, the inverter is faulty and waiting for repair. 3062 3062 3063 -|(% rowspan="2" %)FA.21|Interval for fault self-recovery|Factory default|1.0s 3064 -|Setting range|(% colspan="2" %)0.1 to 100.0ms 3018 +|(% rowspan="2" style="text-align:center" %)FA.21|(% style="text-align:center" %)Interval for fault self-recovery|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1.0s 3019 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.1 to 100.0ms 3065 3065 3066 3066 VFD from fault alarm to automatic reset fault waiting time. 3067 3067 3068 - 3069 -|(% rowspan="2" %)FA.22|Instant stop non-stop function selection|Factory default|0000 3070 -|Setting range|(% colspan="2" %)((( 3023 +|(% rowspan="2" style="text-align:center" %)FA.22|(% style="text-align:center" %)Instant stop non-stop function selection|(% style="text-align:center" %)Factory default|0000 3024 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3071 3071 One place: Power loss ride-through enabled 3072 3072 3073 3073 0: Disabled ... ... @@ -3081,8 +3081,6 @@ 3081 3081 1: Stop 3082 3082 ))) 3083 3083 3084 - 3085 - 3086 3086 Ones place: Power loss ride-through enabled 3087 3087 3088 3088 0: Disable power loss ride-through . 1: Enable power loss ride-through. ... ... @@ -3095,28 +3095,29 @@ 3095 3095 3096 3096 1: Shut down immediately 3097 3097 3098 -|(% rowspan="2" %)FA.23|Power loss ride-through voltage threshold|Factory default|75% 3099 -|Setting range|(% colspan="2" %)40% to 150% 3100 -|(% rowspan="2" %)FA.24|Power loss ride-through stable voltage|Factory default|95% 3101 -|Setting range|(% colspan="2" %)60% to 150% 3050 +|(% rowspan="2" style="text-align:center" %)FA.23|(% style="text-align:center" %)Power loss ride-through voltage threshold|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)75% 3051 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)40% to 150% 3052 +|(% rowspan="2" style="text-align:center" %)FA.24|(% style="text-align:center" %)Power loss ride-through stable voltage|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)95% 3053 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)60% to 150% 3102 3102 3103 3103 When the input power is reduced or power off, the inverter can control the motor speed down to feedback energy to avoid the VFD under voltage fault, the function is called power loss ride-through . When the bus voltage is lower than the rated bus voltage *FA.24, The power loss ride-through function is active. and control the motor to feedback energy to stabilize the bus voltage at the rated bus voltage *FA.24. 3104 3104 3057 +== **FB group swing frequency, fixed length and counting** == 3105 3105 3106 -**FB group swing frequency, fixed length and counting** 3107 - 3108 3108 Swing frequency function is suitable for textile, chemical fiber and other industries and need transverse movement, winding function occasions. 3109 3109 3110 3110 The function of swing frequency means that the output frequency of the inverter swings up and down with the set frequency as the center. 3111 3111 3112 -[[image:1763107356738-341.png]] 3063 +(% style="text-align:center" %) 3064 +((( 3065 +(% style="display:inline-block" %) 3066 +[[Figure 9-B-1 Schematic diagram of swing frequency operation>>image:1763107356738-341.png]] 3067 +))) 3113 3113 3114 -Figure 9-B-1 Schematic diagram of swing frequency operation 3069 +|(% rowspan="2" style="text-align:center" %)FB.00|(% style="text-align:center" %)Swing frequency control|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3070 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3071 +LED ones digit: Swing frequency control 3115 3115 3116 -|(% rowspan="2" %)FB.00|Swing frequency control|Factory default|0 3117 -|Setting range|(% colspan="2" %)((( 3118 -LED ones diigt: Swing frequency control 3119 - 3120 3120 0: The swing frequency control is disable 3121 3121 3122 3122 1: Swing frequency control is effective ... ... @@ -3136,7 +3136,7 @@ 3136 3136 LED thousands digit: Reserved 3137 3137 ))) 3138 3138 3139 -LED ones di igt: Swing frequency control enable3092 +LED ones digit: Swing frequency control enable 3140 3140 3141 3141 LED tens digit: 3142 3142 ... ... @@ -3148,14 +3148,14 @@ 3148 3148 3149 3149 1: Fixed amplitude, relative to maximum frequency (F0.10 maximum output frequency), it is a fixed amplitude system. 3150 3150 3151 -|(% rowspan="2" %)FB.01|Swing preset frequency|Factory default|0.00Hz 3152 -|Setting range|(% colspan="2" %)0.00 to Maximum frequency 3153 -|(% rowspan="2" %)FB.02|Preset frequency duration|Factory default|0.00s 3154 -|Setting range|(% colspan="2" %)0.00 to 650.00s 3155 -|(% rowspan="2" %)FB.03|Swing amplitude|Factory default|0.0% 3156 -|Setting range|(% colspan="2" %)0.0% to 100.0% 3157 -|(% rowspan="2" %)FB.04|Jump frequency amplitude|Factory default|0.0% 3158 -|Setting range|(% colspan="2" %)0.0% to 50.0% 3104 +|(% rowspan="2" style="text-align:center" %)FB.01|(% style="text-align:center" %)Swing preset frequency|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00Hz 3105 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to Maximum frequency 3106 +|(% rowspan="2" style="text-align:center" %)FB.02|(% style="text-align:center" %)Preset frequency duration|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.00s 3107 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 650.00s 3108 +|(% rowspan="2" style="text-align:center" %)FB.03|(% style="text-align:center" %)Swing amplitude|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 3109 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 100.0% 3110 +|(% rowspan="2" style="text-align:center" %)FB.04|(% style="text-align:center" %)Jump frequency amplitude|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0% 3111 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0% to 50.0% 3159 3159 3160 3160 The value of swing amplitude and jump frequency can be determined by this parameter. The operating frequency of swing frequency is constrained by the upper and lower frequency. 3161 3161 ... ... @@ -3169,30 +3169,23 @@ 3169 3169 3170 3170 If the swing is selected relative to the Maximum frequency (fixed swing, select FB.00=1), the jog frequency is fixed. 3171 3171 3125 +|(% rowspan="2" style="text-align:center" %)FB.05|(% style="text-align:center" %)Swing frequency rise time|(% style="text-align:center" %)Factory default|5.00s 3126 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 650.00s 3127 +|(% rowspan="2" style="text-align:center" %)FB.06|(% style="text-align:center" %)Swing frequency drop time|(% style="text-align:center" %)Factory default|5.00s 3128 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.00 to 650.00s 3172 3172 3173 -|(% rowspan="2" %)FB.05|Swing frequency rise time|Factory default|5.00s 3174 -|Setting range|(% colspan="2" %)0.00 to 650.00s 3175 -|(% rowspan="2" %)FB.06|Swing frequency drop time|Factory default|5.00s 3176 -|Setting range|(% colspan="2" %)0.00 to 650.00s 3177 - 3178 - 3179 - 3180 3180 Triangle wave rise time = swing frequency duration FB.02× delta wave rise time coefficient FB.05 (unit: s). 3181 3181 Triangle wave fall time = swing frequency duration FB.02× (1- triangle wave rise time coefficient FB.06) (unit: s). 3182 3182 3133 +== **FC Group communication parameters** == 3183 3183 3135 +|(% rowspan="2" style="text-align:center" %)FC.00|(% style="text-align:center" %)Local address|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 3136 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)1 to 247, 0 is the broadcast address 3184 3184 3185 - 3186 - 3187 -**FC Group communication parameters** 3188 - 3189 -|(% rowspan="2" %)FC.00|Local address|Factory default|1 3190 -|Setting range|(% colspan="2" %)1 to 247, 0 is the broadcast address 3191 - 3192 3192 When the local address is set to 0, it is the broadcast address, and the host computer broadcast function is realized. The local address is unique (except the broadcast address), which is the basis of point-to-point communication between the host computer and the inverter. 3193 3193 3194 -|(% rowspan="2" %)FC.01|Baud rate|Factory default|5 3195 -|Setting range|(% colspan="2" %)((( 3140 +|(% rowspan="2" style="text-align:center" %)FC.01|(% style="text-align:center" %)Baud rate|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)5 3141 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3196 3196 0: 300 bps 3197 3197 3198 3198 1: 600 bps ... ... @@ -3216,8 +3216,8 @@ 3216 3216 3217 3217 This parameter is used to set the data transmission rate between the host computer and the VFD. Note that the baud rate set by the upper computer and the VFD must be consistent, otherwise, communication cannot be carried out. The higher the baud rate, the faster the communication speed. 3218 3218 3219 -|(% rowspan="2" %)FC.02|Modbus data format|Factory default|3 3220 -|Setting range|(% colspan="2" %)((( 3165 +|(% rowspan="2" style="text-align:center" %)FC.02|(% style="text-align:center" %)Modbus data format|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)3 3166 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3221 3221 0: (8.N.2) 8 bits, no parity, 2 stop bits 3222 3222 3223 3223 1: (8.E.1) 8 bits, even parity, 1 stop bit ... ... @@ -3229,22 +3229,20 @@ 3229 3229 3230 3230 The data format set by the upper computer and the inverter must be consistent, otherwise, the communication cannot be carried out. 3231 3231 3232 -|(% rowspan="2" %)FC.03|Modbus Communication response delay|Factory default|2ms 3233 -|Setting range|(% colspan="2" %)0 to 20ms 3178 +|(% rowspan="2" style="text-align:center" %)FC.03|(% style="text-align:center" %)Modbus Communication response delay|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)2ms 3179 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 20ms 3234 3234 3235 3235 Response delay: the intermediate interval between the end of the VFD data acceptance and the sending of data to the upper machine. If the response delay is less than the system processing time, the response delay is based on the system processing time. If the response delay is longer than the system processing time, the system will wait until the response delay time reaches the upper computer before sending the data. 3236 3236 3183 +|(% rowspan="2" style="text-align:center" %)FC.04|(% style="text-align:center" %)Modbus Communication timeout time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s 3184 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 s(In vain), 0.1 to 60.0s 3237 3237 3238 -|(% rowspan="2" %)FC.04|Modbus Communication timeout time|Factory default|0.0s 3239 -|Setting range|(% colspan="2" %)0.0 s(In vain), 0.1-60.0s 3240 - 3241 3241 When the function code is set to 0.0s, the communication timeout parameter is invalid. 3242 3242 3243 3243 When this function code is set to valid value, if the interval between one communication and the next communication exceeds the communication timeout period, the system reports a communication fault error (Err16). Usually, this is set to invalid. If you set the next parameter in a continuous communication system, you can monitor the communication status. 3244 3244 3190 +== **FD Group multi-speed function and simple PLC function** == 3245 3245 3246 -**FD Group multi-speed function and simple PLC function** 3247 - 3248 3248 Simple PLC function is the inverter built-in a programmable controller (PLC) to complete the automatic control of multi-segment frequency logic. Operation time, operation direction and operation frequency can be set to meet the requirements of the process. This series of inverter can realize 16 speed change control, there are 4 kinds of acceleration and deceleration time to choose. When the set PLC completes a cycle, an ON signal can be output by the multifunctional digital output terminal DO1, DO2 or the multifunctional relay relay 1, relay 2. See F1.02 to F1.05 for details. When the frequency source F0.07, F0.03, F0.04 is selected to determine the multi-speed operation mode, FD.00 to FD.15 needs to be set to determine its characteristics. 3249 3249 3250 3250 |(% rowspan="2" %)FD.00|Multi-segment speed instruction 0|Factory default|0 ... ... @@ -3329,73 +3329,72 @@ 3329 3329 3330 3330 PLC shutdown retention: Record the operating stage and operating frequency of the previous PLC during shutdown. 3331 3331 3332 - 3333 -|(% rowspan="2" %)FD.18|PLC stage 0 operation time|Factory default|0.0s(h) 3334 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3335 -|(% rowspan="2" %)FD.19|PLC phase 0 acceleration and deceleration time selection|Factory default|0 3336 -|Setting range|(% colspan="2" %)0to 3 3337 -|(% rowspan="2" %)FD.20|PLC stage 1 operation time|Factory default|0.0s(h) 3338 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3339 -|(% rowspan="2" %)FD.21|PLC phase 1 acceleration and deceleration time selection|Factory default|0 3340 -|Setting range|(% colspan="2" %)0to 3 3341 -|(% rowspan="2" %)FD.22|PLC stage 2 operation time|Factory default|0.0s(h) 3342 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3343 -|(% rowspan="2" %)FD.23|PLC phase 2 acceleration and deceleration time selection|Factory default|0 3344 -|Setting range|(% colspan="2" %)0to 3 3345 -|(% rowspan="2" %)FD.24|PLC stage 3 operation time|Factory default|0.0s(h) 3346 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3347 -|(% rowspan="2" %)FD.25|PLC phase 3 acceleration and deceleration time selection|Factory default|0 3348 -|Setting range|(% colspan="2" %)0to 3 3349 -|(% rowspan="2" %)FD.26|PLC stage 4 operation time|Factory default|0.0s(h) 3350 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3351 -|(% rowspan="2" %)FD.27|PLC phase 4 acceleration and deceleration time selection|Factory default|0 3352 -|Setting range|(% colspan="2" %)0to 3 3353 -|(% rowspan="2" %)FD.28|PLC stage 5 operation time|Factory default|0.0s(h) 3354 -|Setting range|(% colspan="2" %)0.0s(h)-6553.5s(h) 3355 -|(% rowspan="2" %)FD.29|PLC phase 5 acceleration and deceleration time selection|Factory default|0 3356 -|Setting range|(% colspan="2" %)0to 3 3357 -|(% rowspan="2" %)FD.30|PLC stage 6 operation time|Factory default|0.0s(h) 3358 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3359 -|(% rowspan="2" %)FD.31|PLC phase 6 acceleration and deceleration time selection|Factory default|0 3360 -|Setting range|(% colspan="2" %)0to 3 3361 -|(% rowspan="2" %)FD.32|PLC stage 7 operation time|Factory default|0.0s(h) 3362 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3363 -|(% rowspan="2" %)FD.33|PLC phase 7 acceleration and deceleration time selection|Factory default|0 3364 -|Setting range|(% colspan="2" %)0to 3 3365 -|(% rowspan="2" %)FD.34|PLC stage 8 operation time|Factory default|0.0s(h) 3366 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3367 -|(% rowspan="2" %)FD.35|PLC phase 8 acceleration and deceleration time selection|Factory default|0 3368 -|Setting range|(% colspan="2" %)0to 3 3369 -|(% rowspan="2" %)FD.36|PLC stage 9 operation time|Factory default|0.0s(h) 3370 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3371 -|(% rowspan="2" %)FD.37|PLC phase 9 acceleration and deceleration time selection|Factory default|0 3372 -|Setting range|(% colspan="2" %)0 to 3 3373 -|(% rowspan="2" %)FD.38|PLC stage 10 operation time|Factory default|0.0s(h) 3374 -|Setting range|(% colspan="2" %)0.0 s(h) to 6553.5s(h) 3375 -|(% rowspan="2" %)FD.39|PLC phase 10 acceleration and deceleration time selection|Factory default|0 3376 -|Setting range|(% colspan="2" %)0 to 3 3377 -|(% rowspan="2" %)FD.40|PLC stage 11 operation time|Factory default|0.0s(h) 3378 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3379 -|(% rowspan="2" %)FD.41|PLC phase 11 acceleration and deceleration time selection|Factory default|0 3380 -|Setting range|(% colspan="2" %)0 to 3 3381 -|(% rowspan="2" %)FD.42|PLC stage 12 operation time|Factory default|0.0s(h) 3382 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3383 -|(% rowspan="2" %)FD.43|PLC phase 12 acceleration and deceleration time selection|Factory default|0 3384 -|Setting range|(% colspan="2" %)0 to 3 3385 -|(% rowspan="2" %)FD.44|PLC stage 13 operation time|Factory default|0.0s(h) 3386 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3387 -|(% rowspan="2" %)FD.45|PLC phase 13 acceleration and deceleration time selection|Factory default|0 3388 -|Setting range|(% colspan="2" %)0 to 3 3389 -|(% rowspan="2" %)FD.46|PLC stage 14 operation time|Factory default|0.0s(h) 3390 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3391 -|(% rowspan="2" %)FD.47|PLC phase 14 acceleration and deceleration time selection|Factory default|0 3392 -|Setting range|(% colspan="2" %)0 to 3 3393 -|(% rowspan="2" %)FD.48|PLC stage 15 operation time|Factory default|0.0s(h) 3394 -|Setting range|(% colspan="2" %)0.0s(h) to 6553.5s(h) 3395 -|(% rowspan="2" %)FD.49|PLC phase 15 acceleration and deceleration time selection|Factory default|0 3396 -|Setting range|(% colspan="2" %)0 to 3 3397 -|(% rowspan="2" %)FD.50|PLC operating time unit|Factory default|0 3398 -|Setting range|(% colspan="2" %)((( 3276 +|(% rowspan="2" style="text-align:center" %)FD.18|(% style="text-align:center" %)PLC stage 0 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3277 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3278 +|(% rowspan="2" style="text-align:center" %)FD.19|(% style="text-align:center" %)PLC phase 0 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3279 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3280 +|(% rowspan="2" style="text-align:center" %)FD.20|(% style="text-align:center" %)PLC stage 1 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3281 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3282 +|(% rowspan="2" style="text-align:center" %)FD.21|(% style="text-align:center" %)PLC phase 1 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3283 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3284 +|(% rowspan="2" style="text-align:center" %)FD.22|(% style="text-align:center" %)PLC stage 2 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3285 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3286 +|(% rowspan="2" style="text-align:center" %)FD.23|(% style="text-align:center" %)PLC phase 2 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3287 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3288 +|(% rowspan="2" style="text-align:center" %)FD.24|(% style="text-align:center" %)PLC stage 3 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3289 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3290 +|(% rowspan="2" style="text-align:center" %)FD.25|(% style="text-align:center" %)PLC phase 3 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3291 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3292 +|(% rowspan="2" style="text-align:center" %)FD.26|(% style="text-align:center" %)PLC stage 4 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3293 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3294 +|(% rowspan="2" style="text-align:center" %)FD.27|(% style="text-align:center" %)PLC phase 4 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3295 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3296 +|(% rowspan="2" style="text-align:center" %)FD.28|(% style="text-align:center" %)PLC stage 5 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3297 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h)-6553.5s(h) 3298 +|(% rowspan="2" style="text-align:center" %)FD.29|(% style="text-align:center" %)PLC phase 5 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3299 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3300 +|(% rowspan="2" style="text-align:center" %)FD.30|(% style="text-align:center" %)PLC stage 6 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3301 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3302 +|(% rowspan="2" style="text-align:center" %)FD.31|(% style="text-align:center" %)PLC phase 6 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3303 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3304 +|(% rowspan="2" style="text-align:center" %)FD.32|(% style="text-align:center" %)PLC stage 7 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3305 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3306 +|(% rowspan="2" style="text-align:center" %)FD.33|(% style="text-align:center" %)PLC phase 7 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3307 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3308 +|(% rowspan="2" style="text-align:center" %)FD.34|(% style="text-align:center" %)PLC stage 8 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3309 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3310 +|(% rowspan="2" style="text-align:center" %)FD.35|(% style="text-align:center" %)PLC phase 8 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3311 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0to 3 3312 +|(% rowspan="2" style="text-align:center" %)FD.36|(% style="text-align:center" %)PLC stage 9 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3313 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3314 +|(% rowspan="2" style="text-align:center" %)FD.37|(% style="text-align:center" %)PLC phase 9 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3315 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3316 +|(% rowspan="2" style="text-align:center" %)FD.38|(% style="text-align:center" %)PLC stage 10 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3317 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0 s(h) to 6553.5s(h) 3318 +|(% rowspan="2" style="text-align:center" %)FD.39|(% style="text-align:center" %)PLC phase 10 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3319 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3320 +|(% rowspan="2" style="text-align:center" %)FD.40|(% style="text-align:center" %)PLC stage 11 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3321 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3322 +|(% rowspan="2" style="text-align:center" %)FD.41|(% style="text-align:center" %)PLC phase 11 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3323 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3324 +|(% rowspan="2" style="text-align:center" %)FD.42|(% style="text-align:center" %)PLC stage 12 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3325 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3326 +|(% rowspan="2" style="text-align:center" %)FD.43|(% style="text-align:center" %)PLC phase 12 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3327 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3328 +|(% rowspan="2" style="text-align:center" %)FD.44|(% style="text-align:center" %)PLC stage 13 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3329 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3330 +|(% rowspan="2" style="text-align:center" %)FD.45|(% style="text-align:center" %)PLC phase 13 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3331 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3332 +|(% rowspan="2" style="text-align:center" %)FD.46|(% style="text-align:center" %)PLC stage 14 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3333 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3334 +|(% rowspan="2" style="text-align:center" %)FD.47|(% style="text-align:center" %)PLC phase 14 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3335 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3336 +|(% rowspan="2" style="text-align:center" %)FD.48|(% style="text-align:center" %)PLC stage 15 operation time|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0.0s(h) 3337 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0.0s(h) to 6553.5s(h) 3338 +|(% rowspan="2" style="text-align:center" %)FD.49|(% style="text-align:center" %)PLC phase 15 acceleration and deceleration time selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3339 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 3 3340 +|(% rowspan="2" style="text-align:center" %)FD.50|(% style="text-align:center" %)PLC operating time unit|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3341 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:left" %)((( 3399 3399 LED units: Timing unit 3400 3400 3401 3401 0: s(seconds) ... ... @@ -3404,15 +3404,15 @@ 3404 3404 3405 3405 2: min(minutes) 3406 3406 ))) 3407 -|(% rowspan="2" %)FD.51|Multi-segment speed instruction 0 given mode|Factory default|0 3408 -|Setting range|(% colspan="2" %)((( 3350 +|(% rowspan="2" style="text-align:center" %)FD.51|(% style="text-align:center" %)Multi-segment speed instruction 0 given mode|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3351 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3409 3409 0: Function code FD.00 given 3410 3410 3411 -1: AI1 3354 +1: AI1 given 3412 3412 3413 -2: AI2 3356 +2: AI2 given 3414 3414 3415 -3: AI3 3358 +3: AI3 given 3416 3416 3417 3417 4: Set the terminal PULSE 3418 3418 ... ... @@ -3420,18 +3420,15 @@ 3420 3420 3421 3421 6: Preset frequency (F0.08) given, UP/DOWN can be modified 3422 3422 3423 -7: keyboard potentiometer set3366 +7: Keyboard potentiometer set 3424 3424 ))) 3425 3425 3426 - 3427 - 3428 3428 This parameter determines the target amount of the multi-segment speed 0 given channel. 3429 3429 3430 3430 FD.50: PLC operating time unit. 3431 3431 3432 - 3433 -|(% rowspan="2" %)FD.52|Multiple speed is preferred|Factory default|1 3434 -|Set range|(% colspan="2" %)((( 3373 +|(% rowspan="2" style="text-align:center" %)FD.52|(% style="text-align:center" %)Multiple speed is preferred|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)1 3374 +|(% style="text-align:center" %)Set range|(% colspan="2" style="text-align:center" %)((( 3435 3435 0: Invalid 3436 3436 3437 3437 1: Valid ... ... @@ -3439,21 +3439,20 @@ 3439 3439 3440 3440 Set this parameter to 1, F0.03 set the main frequency source not to multi-segment speed, and set F5 group terminal parameter multi-segment speed function~,~, when the terminal is valid, the frequency source switches to the multi-segment speed set, the multi-segment speed priority has nothing to do with the multi-segment speed 0. 3441 3441 3442 -**FE Group user password** 3382 +== **FE Group user password** == 3443 3443 3444 -|(% rowspan="2" %)FE.00|User password|Factory default|0 3445 -|Setting range|(% colspan="2" %)0 to 65535 3384 +|(% rowspan="2" style="text-align:center" %)FE.00|(% style="text-align:center" %)User password|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3385 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 65535 3446 3446 3447 3447 If the value is set to any non-zero number, the password protection function takes effect. 00000: Clears the previously set password value and invalidates the password protection function. After the user password is set and takes effect, if you enter the parameter setting state again and the user password is incorrect, the parameter group cannot be entered and cannot be viewed/modified. Remember the user password you set. If you accidentally set or forget, please contact the manufacturer. 3448 3448 3449 -|(% rowspan="2" %)FE.01|Number of times to display fault records|Factory default|4 3450 -|Setting range|(% colspan="2" %)0 to 8 3389 +|(% rowspan="2" style="text-align:center" %)FE.01|(% style="text-align:center" %)Number of times to display fault records|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)4 3390 +|(% style="text-align:center" %)Setting range|(% colspan="2" style="text-align:center" %)0 to 8 3451 3451 3452 3452 This function code is used to set the number of times that fault records are displayed. 3453 3453 3454 - 3455 -|(% rowspan="2" %)FE.02|Parameter and key lock selection|Factory default|0 3456 -|Setting range|(% colspan="2" %)((( 3394 +|(% rowspan="2" style="text-align:center" %)FE.02|(% style="text-align:center" %)Parameter and key lock selection|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3395 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3457 3457 0: Not locked 3458 3458 3459 3459 1: The function parameter is locked ... ... @@ -3461,11 +3461,10 @@ 3461 3461 3462 3462 This function code is used to lock a parameter. After the parameter is locked, it cannot be modified. 3463 3463 3403 +== **A0 Displays the parameter group** == 3464 3464 3465 -**A0 Displays the parameter group** 3466 - 3467 -|(% rowspan="2" %)A0.00|Application macro|Factory default|0 3468 -|Setting range|(% colspan="2" %)((( 3405 +|(% rowspan="2" style="text-align:center" %)A0.00|(% style="text-align:center" %)Application macro|(% style="text-align:center" %)Factory default|(% style="text-align:center" %)0 3406 +|(% style="text-align:center" %)Setting range|(% colspan="2" %)((( 3469 3469 0: Default macro 3470 3470 3471 3471 1: Tile press macro
- 1763358952427-755.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +637.5 KB - Content
- 1763360417842-953.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.9 KB - Content
- wps2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +418.7 KB - Content